Suitable for use as follows:
Conductor | Ground Wire | ||||||||
No. of Conductors | Size (AWG or kcmil) (mm2) | No. of Strands | Insulation Thickness (mils) (mm) | Size (AWG) | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | |
890347 |
3
3
|
1 AWG
1 AWG
|
19
19
|
50
1.27
|
6
6
|
|
1275
32.39
|
1148
1708
|
|
582068 |
4
4
|
1 AWG
1 AWG
|
19
19
|
50
1.27
|
6
6
|
|
1331
33.81
|
1483
2207
|
|
562656 |
3
3
|
1/0 AWG
1/0 AWG
|
19
19
|
50
1.27
|
6
6
|
|
1241
31.54
|
1360
2024
|
|
890356 |
4
4
|
1/0 AWG
1/0 AWG
|
19
19
|
50
1.27
|
6
6
|
|
1371
34.85
|
1760
2619
|
|
646835 |
5
5
|
1/0 AWG
1/0 AWG
|
19
19
|
50
1.27
|
1/0
1/0
|
|
1633
41.48
|
2346
3491
|
|
640693 |
3
3
|
2/0 AWG
2/0 AWG
|
19
19
|
50
1.27
|
6
6
|
|
1441
36.61
|
1784
2656
|
|
679686 |
4
4
|
2/0 AWG
2/0 AWG
|
19
19
|
50
1.27
|
6
6
|
|
1578
40.08
|
2219
3303
|
|
585747 |
3
3
|
3/0 AWG
3/0 AWG
|
19
19
|
50
1.27
|
3
3
|
|
1713
43.51
|
2374
3533
|
|
561032 |
4
4
|
3/0 AWG
3/0 AWG
|
19
19
|
50
1.27
|
3
3
|
|
1694
43.03
|
2783
4142
|
|
578528 |
3
3
|
4/0 AWG
4/0 AWG
|
19
19
|
50
1.27
|
2
2
|
|
1683
42.75
|
2659
3957
|
|
561034 |
4
4
|
4/0 AWG
4/0 AWG
|
19
19
|
50
1.27
|
2
2
|
|
1795
45.60
|
3399
5059
|
|
677338 |
5
5
|
4/0 AWG
4/0 AWG
|
19
19
|
50
1.27
|
4
4
|
|
2166
55.02
|
4131
6147
|
|
890352 |
3
3
|
250 KCMIL
250 KCMIL
|
37
37
|
60
1.52
|
4
4
|
|
1817
46.15
|
2957
4401
|
|
643537 |
4
4
|
250 KCMIL
250 KCMIL
|
37
37
|
60
1.52
|
2
2
|
|
1954
49.65
|
3994
5944
|
|
565545 |
5
5
|
250 KCMIL
250 KCMIL
|
37
37
|
60
1.52
|
4
4
|
|
2322
58.99
|
4823
7177
|
|
679680 |
4
4
|
300 KCMIL
300 KCMIL
|
37
37
|
60
1.52
|
3
3
|
|
2093
53.16
|
4615
6867
|
|
560114 |
3
3
|
350 KCMIL
350 KCMIL
|
37
37
|
60
1.52
|
3/0
3/0
|
|
2176
55.27
|
4438
6604
|
|
568710 |
4
4
|
350 KCMIL
350 KCMIL
|
37
37
|
60
1.52
|
3/0
3/0
|
|
2387
60.65
|
5706
8491
|
|
678473 |
3
3
|
400 KCMIL
400 KCMIL
|
37
37
|
60
1.52
|
1/0
1/0
|
|
2188
55.58
|
5251
7814
|
|
580929 |
3
3
|
500 KCMIL
500 KCMIL
|
37
37
|
60
1.52
|
1/0
1/0
|
|
2459
62.46
|
6072
9035
|
|
679673 |
4
4
|
500 KCMIL
500 KCMIL
|
37
37
|
60
1.52
|
2/0
2/0
|
|
2523
64.08
|
7502
11165
|
|
677391 |
5
5
|
500 KCMIL
500 KCMIL
|
37
37
|
60
1.52
|
4/0
4/0
|
|
2775
70.50
|
9442
14052
|
|
579943 |
3
3
|
600 KCMIL
600 KCMIL
|
61
61
|
70
1.78
|
4/0
4/0
|
|
2478
62.96
|
7102
10569
|
|
578817 |
4
4
|
600 KCMIL
600 KCMIL
|
61
61
|
70
1.78
|
2
2
|
|
2668
67.77
|
8713
12967
|
|
562658 |
3
3
|
1 AWG
1 AWG
|
19
19
|
50
1.27
|
6
6
|
|
1270
32.27
|
1141
1698
|
|
Southwire's Armorlite® Type MC Cable - Multi-Circuit meets or exceeds the following requirements:
Southwire Copper Riser MC™ is constructed with Type THHN/THWN-2 conductors and a bare equipment grounding conductor. A binder tape is wrapped over the conductors and an integral polymeric binder jacket is applied under armor for continuous conductor support. Aluminum interlocking armor is applied snuggly over the assembly. An optional overall PVC Jacket can be applied over the armor.