Southwire Type SOOW Flexible Cords UL/ CSA listed are permitted for use as specified by Article 400 and related articles of the 2014 National Electrical Code. The cable is rated -40°C to 90°C, water, oil, and weather resistant. Southwire Type SOOW Flexible Cords are designed for extra hard usage on industrial equipment, heavy tools, battery chargers, portable lights, welding leads, marine dockside power, power extensions and mining applications.
Conductor | ||||||||
Size (AWG or kcmil) (mm2) | No. of Conductors | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | Nom. DC Resistance (Conductor) | Conductor Colors | |
More Options |
18 AWG
18 AWG
|
6
6
|
16
16
|
492
12.50
|
142
211
|
5.5
5.5
|
6.59
6.59
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|
More Options |
18 AWG
18 AWG
|
7
7
|
16
16
|
488
12.40
|
140
208
|
4.5
4.5
|
6.59
6.59
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
|
More Options |
18 AWG
18 AWG
|
8
8
|
16
16
|
521
13.23
|
164
244
|
4.5
4.5
|
6.59
6.59
|
BLACK/RED-BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
BLACK/RED-BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
|
More Options |
18 AWG
18 AWG
|
10
10
|
16
16
|
596
15.14
|
202
301
|
3.5
3.5
|
6.59
6.59
|
|
More Options |
18 AWG
18 AWG
|
12
12
|
16
16
|
605
15.37
|
218
324
|
3.5
3.5
|
6.59
6.59
|
|
More Options |
18 AWG
18 AWG
|
14
14
|
16
16
|
640
16.26
|
246
366
|
3.5
3.5
|
6.59
6.59
|
|
More Options |
18 AWG
18 AWG
|
16
16
|
16
16
|
668
16.97
|
274
408
|
3.5
3.5
|
6.59
6.59
|
|
More Options |
18 AWG
18 AWG
|
20
20
|
16
16
|
739
18.77
|
321
477
|
3.5
3.5
|
6.59
6.59
|
|
More Options |
18 AWG
18 AWG
|
24
24
|
16
16
|
830
21.08
|
405
603
|
3
3
|
6.59
6.59
|
|
More Options |
18 AWG
18 AWG
|
30
30
|
16
16
|
849
21.56
|
446
663
|
3
3
|
6.59
6.59
|
|
More Options |
16 AWG
16 AWG
|
6
6
|
26
26
|
516
13.11
|
169
251
|
8
8
|
4.05
4.05
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|
More Options |
16 AWG
16 AWG
|
7
7
|
26
26
|
564
14.33
|
203
302
|
7
7
|
4.05
4.05
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
|
More Options |
16 AWG
16 AWG
|
8
8
|
26
26
|
515
13.08
|
192
285
|
7
7
|
4.05
4.05
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
|
More Options |
16 AWG
16 AWG
|
10
10
|
26
26
|
648
16.46
|
255
379
|
5
5
|
4.05
4.05
|
|
More Options |
16 AWG
16 AWG
|
12
12
|
26
26
|
700
17.78
|
336
500
|
5
5
|
4.05
4.05
|
|
More Options |
16 AWG
16 AWG
|
14
14
|
26
26
|
727
18.47
|
340
506
|
5
5
|
4.05
4.05
|
|
More Options |
16 AWG
16 AWG
|
16
16
|
26
26
|
778
19.76
|
372
553
|
5
5
|
4.05
4.05
|
|
More Options |
16 AWG
16 AWG
|
20
20
|
26
26
|
745
18.92
|
397
591
|
5
5
|
4.05
4.05
|
|
More Options |
16 AWG
16 AWG
|
30
30
|
26
26
|
982
24.94
|
642
956
|
4.5
4.5
|
4.05
4.05
|
|
More Options |
14 AWG
14 AWG
|
6
6
|
41
41
|
718
18.24
|
314
468
|
12
12
|
2.55
2.55
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|
More Options |
14 AWG
14 AWG
|
7
7
|
41
41
|
712
18.08
|
320
477
|
10
10
|
2.55
2.55
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
|
More Options |
14 AWG
14 AWG
|
8
8
|
41
41
|
730
18.54
|
339
504
|
10
10
|
2.55
2.55
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
|
More Options |
14 AWG
14 AWG
|
10
10
|
41
41
|
770
19.56
|
404
601
|
7
7
|
2.55
2.55
|
|
More Options |
14 AWG
14 AWG
|
12
12
|
41
41
|
883
22.43
|
477
710
|
7
7
|
2.55
2.55
|
|
More Options |
14 AWG
14 AWG
|
16
16
|
41
41
|
1020
25.91
|
633
943
|
7
7
|
2.55
2.55
|
|
More Options |
12 AWG
12 AWG
|
6
6
|
65
65
|
740
18.80
|
390
580
|
16
16
|
1.61
1.61
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|
More Options |
12 AWG
12 AWG
|
7
7
|
65
65
|
740
18.80
|
353
525
|
14
14
|
1.61
1.61
|
BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
|
More Options |
12 AWG
12 AWG
|
8
8
|
65
65
|
803
20.40
|
445
662
|
14
14
|
1.61
1.61
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
|
More Options |
12 AWG
12 AWG
|
9
9
|
65
65
|
852
21.64
|
483
719
|
14
14
|
1.61
1.61
|
|
More Options |
12 AWG
12 AWG
|
10
10
|
65
65
|
894
22.71
|
501
745
|
10
10
|
1.61
1.61
|
|
More Options |
12 AWG
12 AWG
|
12
12
|
65
65
|
987
25.07
|
627
934
|
10
10
|
1.61
1.61
|
|
More Options |
12 AWG
12 AWG
|
14
14
|
65
65
|
1035
26.29
|
705
1049
|
10
10
|
1.61
1.61
|
|
More Options |
12 AWG
12 AWG
|
16
16
|
65
65
|
1089
27.66
|
810
1205
|
10
10
|
1.61
1.61
|
|
More Options |
10 AWG
10 AWG
|
6
6
|
104
104
|
830
21.08
|
488
726
|
20
20
|
0.98
0.98
|
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
BLACK/WHITE/RED/GREEN/ORANGE/BLUE
|
More Options |
10 AWG
10 AWG
|
7
7
|
104
104
|
840
21.34
|
520
774
|
17
17
|
0.98
0.98
|
BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
BLACK/WHITE-BLACK/BLUE/ORANGE/GREEN/RED/WHITE
|
More Options |
10 AWG
10 AWG
|
12
12
|
104
104
|
1067
27.10
|
848
1262
|
12
12
|
0.98
0.98
|
|