Southwire’s 600 Volt power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. CT Rated 1/0 and Larger - Sunlight Resistant - Silicone Free. Rated for 1000 lbs./FT maximum sidewall pressure.
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Drain Wire | Diameter Over Shield (in) (cm) | Inner Jacket Thickness (mils) (mm) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | |
890105 |
1/0
1/0
|
0.0
0.0
|
19
19
|
0.361
0.92
|
80
2.03
|
|
|
|
|
|
|
|
0.530
1.35
|
326
485
|
|
396
589
|
890106 |
2/0
2/0
|
1.0
1.0
|
19
19
|
0.405
1.03
|
80
2.03
|
|
|
|
|
|
|
|
0.572
1.45
|
410
610
|
|
488
726
|
890631 |
3/0
3/0
|
1.0
1.0
|
19
19
|
0.456
1.16
|
80
2.03
|
|
|
|
|
|
|
|
0.624
1.58
|
518
771
|
|
603
897
|
890107 |
4/0
4/0
|
1.0
1.0
|
19
19
|
0.512
1.30
|
80
2.03
|
|
|
|
|
|
|
|
0.680
1.73
|
653
972
|
|
748
1113
|
890632 |
250
250
|
1.0
1.0
|
37
37
|
0.558
1.42
|
95
2.41
|
|
|
|
|
|
|
|
0.742
1.88
|
771
1147
|
|
892
1327
|
890108 |
350
350
|
1.0
1.0
|
37
37
|
0.661
1.68
|
95
2.41
|
|
|
|
|
|
|
|
0.861
2.19
|
1080
1607
|
|
1223
1820
|
890109 |
500
500
|
1.0
1.0
|
37
37
|
0.789
2.00
|
95
2.41
|
|
|
|
|
|
|
|
0.966
2.45
|
1543
2296
|
|
1707
2540
|
890633 |
750
750
|
1.0
1.0
|
61
61
|
0.968
2.46
|
110
2.79
|
|
|
|
|
|
|
|
1.171
2.97
|
2315
3445
|
|
2544
3786
|
Cond. Size (AWG/Kcmil) | Conductor Number | Min. Bend Radius (in) (cm) | Max Pull Tension (lbs) (kg) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Capacitive Reactance (Mohms x 1000ft) (Mohms x km) | Inductive Reactance (ohms/1000') (ohms/km) | Shield Short Circuit Current 6 Cycles (amps) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
890105 |
1/0
1/0
|
0.0
0.0
|
2.1
5.33
|
844
382.83
|
0.102
0.15
|
0.122
0.18
|
|
0.044
0.07
|
|
150
150
|
170
170
|
890106 |
2/0
2/0
|
1.0
1.0
|
2.2
5.59
|
1064
482.62
|
0.081
0.12
|
0.097
0.14
|
|
0.043
0.06
|
|
175
175
|
195
195
|
890631 |
3/0
3/0
|
1.0
1.0
|
2.4
6.10
|
1342
608.72
|
0.064
0.10
|
0.078
0.12
|
|
0.042
0.06
|
|
200
200
|
225
225
|
890107 |
4/0
4/0
|
1.0
1.0
|
2.7
6.86
|
1692
767.48
|
0.051
0.08
|
0.062
0.09
|
|
0.041
0.06
|
|
230
230
|
260
260
|
890632 |
250
250
|
1.0
1.0
|
2.9
7.37
|
2000
907.18
|
0.043
0.06
|
0.053
0.08
|
|
0.041
0.06
|
|
255
255
|
290
290
|
890108 |
350
350
|
1.0
1.0
|
3.4
8.64
|
2800
1270.06
|
0.031
0.05
|
0.039
0.06
|
|
0.04
0.06
|
|
310
310
|
350
350
|
890109 |
500
500
|
1.0
1.0
|
3.8
9.65
|
4000
1814.37
|
0.022
0.03
|
0.029
0.04
|
|
0.039
0.06
|
|
380
380
|
430
430
|
890633 |
750
750
|
1.0
1.0
|
5.9
14.99
|
6000
2721.55
|
0.014
0.02
|
0.022
0.03
|
|
0.038
0.06
|
|
475
475
|
535
535
|