SPEC25066 DURAGROUND™ CU 600V XLPE Insulation. RHH/RHW-2/RW90 UL & CSA

Single Copper Conductors, XLPE Insulation, Sunlight Resistant, 600V, 90°C MAX, -40°C MIN, Gasoline & Oil Resistant

Download Category Specifications
PDF Excel Table

Application

Suitable for installation in Cable Trays and Underground Duct Banks - As per CE Code limitations (see Rule 12-2202) for grounding and bonding applications.

Specifications

Select a set of products below for more information:
Cond. Size (AWG/Kcmil) Conductor Number Cond. Strands Diameter Over Conductor (in) (cm) Insulation Thickness (mils) (mm) Diameter Over Insulation (in) (cm) Ground (No. x AWG) Drain Wire Diameter Over Shield (in) (cm) Inner Jacket Thickness (mils) (mm) Diameter Over Armor (in) (cm) Jacket Thickness (mils) (mm) Approx. OD (in) (cm) Copper Weight (lbs/1000') (kgs/km) Aluminum Weight (lbs/1000') (kgs/km) Approx. Weight (lbs/1000') (kgs/km)
649033
6 6
1.0 1.0
7 7
0.177 0.45
60 1.52
0.300 0.76
81 121
108 161
649039
2 2
1.0 1.0
7 7
0.282 0.72
60 1.52
0.403 1.02
204 304
245 365
649041
2/0 2/0
1.0 1.0
19 19
0.405 1.03
80 2.03
0.574 1.46
410 610
487 725
649043
4/0 4/0
1.0 1.0
19 19
0.512 1.30
80 2.03
0.666 1.69
653 972
745 1109
649054
350 350
1.0 1.0
37 37
0.661 1.68
95 2.41
0.841 2.14
1080 1607
1218 1813
649056
500 500
1.0 1.0
37 37
0.789 2.00
95 2.41
0.966 2.45
1543 2296
1705 2537
649058
750 750
1.0 1.0
61 61
0.968 2.46
110 2.79
1.200 3.05
2315 3445
2549 3793
649060
1000 1000
1.0 1.0
61 61
1.117 2.84
110 2.79
1.349 3.43
3087 4594
3354 4991
649054
350 350
1.0 1.0
37 37
0.661 1.68
95 2.41
0.841 2.14
1080 1607
1218 1813
Cond. Size (AWG/Kcmil) Conductor Number Min. Bend Radius (in) (cm) Max Pull Tension (lbs) (kg) DC Resistance @ 25C (ohms/1000') (ohms/km) AC Resistance @ 75C (ohms/1000') (ohms/km) Capacitive Reactance (Mohms x 1000ft) (Mohms x km) Inductive Reactance (ohms/1000') (ohms/km) Shield Short Circuit Current 6 Cycles (amps) Raceway Ampacity @ 75C (amps) Raceway Ampacity @ 90C (amps)
649033
6 6
1.0 1.0
1.2 3.05
209 94.80
0.411 0.61
0.495 0.74
0.051 0.08
65 65
75 75
649039
2 2
1.0 1.0
1.6 4.06
530 240.40
0.162 0.24
0.195 0.29
0.045 0.07
115 115
130 130
649041
2/0 2/0
1.0 1.0
2.2 5.59
1064 482.62
0.081 0.12
0.097 0.14
0.043 0.06
175 175
195 195
649043
4/0 4/0
1.0 1.0
2.6 6.60
1692 767.48
0.051 0.08
0.062 0.09
0.041 0.06
230 230
260 260
649054
350 350
1.0 1.0
3.3 8.38
2800 1270.06
0.031 0.05
0.039 0.06
0.04 0.06
310 310
350 350
649056
500 500
1.0 1.0
3.8 9.65
4000 1814.37
0.022 0.03
0.029 0.04
0.039 0.06
380 380
430 430
649058
750 750
1.0 1.0
6.0 15.24
6000 2721.55
0.014 0.02
0.022 0.03
0.038 0.06
475 475
535 535
649060
1000 1000
1.0 1.0
6.7 17.02
8000 3628.74
0.011 0.02
0.018 0.03
0.037 0.06
545 545
615 615
649054
350 350
1.0 1.0
3.3 8.38
2800 1270.06
0.031 0.05
0.039 0.06
0.04 0.06
310 310
350 350

Standards & References

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • CSA C22.2 No. 38 Thermoset-insulated wires and cables
  • CSA SUN RES - for Sunlight Resistant rating
  • CT USE Sizes 1/0 AWG and Larger
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • RoHS-2 (European Directive 2011/65/EU)

Construction

  1. Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
  2. Insulation: Cross Linked Polyethylene (XLPE) Type RW90