Southwire’s 600 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Sunlight Resistant - For Direct Burial - Silicone Free
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Color | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Min. Bend Radius (in) (cm) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
890674 |
14
14
|
2.0
2.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.355
0.90
|
25
37
|
|
67
100
|
2.631
3.92
|
3.17
4.72
|
1.4
3.56
|
20
20
|
25
25
|
890675 |
14
14
|
3.0
3.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.376
0.96
|
38
57
|
|
91
135
|
2.631
3.92
|
3.17
4.72
|
1.5
3.81
|
20
20
|
25
25
|
890676 |
14
14
|
4.0
4.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.409
1.04
|
51
76
|
|
111
165
|
2.631
3.92
|
3.17
4.72
|
1.6
4.06
|
16
16
|
20
20
|
890677 |
14
14
|
5.0
5.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.447
1.14
|
64
95
|
|
129
192
|
2.631
3.92
|
3.17
4.72
|
1.8
4.57
|
16
16
|
20
20
|
890678 |
14
14
|
7.0
7.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.486
1.23
|
89
132
|
|
172
256
|
2.631
3.92
|
3.17
4.72
|
1.9
4.83
|
14
14
|
17
17
|
890679 |
14
14
|
9.0
9.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.592
1.50
|
114
170
|
|
232
345
|
2.631
3.92
|
3.17
4.72
|
2.4
6.10
|
14
14
|
17
17
|
550407 |
14
14
|
12.0
12.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.670
1.70
|
153
228
|
|
299
445
|
2.631
3.92
|
3.17
4.72
|
2.7
6.86
|
10
10
|
12
12
|
550411 |
12
12
|
2.0
2.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.388
0.99
|
40
60
|
|
89
132
|
1.662
2.47
|
2.002
2.98
|
1.6
4.06
|
25
25
|
30
30
|
890681 |
12
12
|
3.0
3.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.412
1.05
|
61
91
|
|
120
179
|
1.662
2.47
|
2.002
2.98
|
1.6
4.06
|
25
25
|
30
30
|
890682 |
12
12
|
4.0
4.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.449
1.14
|
81
121
|
|
154
229
|
1.662
2.47
|
2.002
2.98
|
1.8
4.57
|
20
20
|
24
24
|
890683 |
12
12
|
5.0
5.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.491
1.25
|
101
150
|
|
178
265
|
1.662
2.47
|
2.002
2.98
|
2.0
5.08
|
20
20
|
24
24
|
890684 |
12
12
|
12.0
12.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.738
1.87
|
244
363
|
|
408
607
|
1.662
2.47
|
2.002
2.98
|
3.0
7.62
|
12
12
|
15
15
|
890685 |
10
10
|
3.0
3.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.476
1.21
|
97
144
|
|
169
251
|
1.04
1.55
|
1.253
1.86
|
1.9
4.83
|
35
35
|
40
40
|
890686 |
10
10
|
4.0
4.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.547
1.39
|
129
192
|
|
228
339
|
1.04
1.55
|
1.253
1.86
|
2.2
5.59
|
28
28
|
32
32
|
550420 |
10
10
|
5.0
5.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.603
1.53
|
161
240
|
|
275
409
|
1.04
1.55
|
1.253
1.86
|
2.4
6.10
|
28
28
|
32
32
|
550421 |
10
10
|
7.0
7.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.657
1.67
|
226
336
|
|
364
542
|
1.04
1.55
|
1.253
1.86
|
2.6
6.60
|
24
24
|
28
28
|