Southwire Type SJEOOW Flexible Cords are permitted for Indoor and outdoor temporary power uses, portable industrial machinery, compressors, conveyor and automated production equipment. Cords are suitable for use in temperatures between -50°C to maximum 105°C.
Conductor | ||||||||
Size (AWG or kcmil) (mm2) | No. of Conductors | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | Nom. DC Resistance (Conductor) | Conductor Colors | |
More Options |
18 AWG
18 AWG
|
3
3
|
16
16
|
308
7.82
|
48
71
|
10
10
|
6.59
6.59
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
More Options |
16 AWG
16 AWG
|
3
3
|
26
26
|
331
8.41
|
61
91
|
13
13
|
4.05
4.05
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
More Options |
14 AWG
14 AWG
|
2
2
|
41
41
|
340
8.64
|
60
89
|
18
18
|
2.55
2.55
|
BLACK/WHITE
BLACK/WHITE
|
More Options |
14 AWG
14 AWG
|
3
3
|
41
41
|
366
9.30
|
81
120
|
18
18
|
2.55
2.55
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
More Options |
12 AWG
12 AWG
|
3
3
|
65
65
|
436
11.07
|
122
181
|
25
25
|
1.61
1.61
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|
More Options |
10 AWG
10 AWG
|
3
3
|
104
104
|
576
14.63
|
205
306
|
30
30
|
0.98
0.98
|
BLACK/WHITE/GREEN
BLACK/WHITE/GREEN
|