SPEC44030 1/C CU EPR Medium Voltage Non-Shielded Jumper & Switchgear Cable

Single Conductor Flexible Conductor with an EPR Insulation Non-Shielded Jumper Cable

Download Category Specifications
PDF Excel Table

Application

Southwire’s medium voltage non-shielded jumper and switchgear cable is a flexible power cable that is intended for use in substations installed on insulators and inside switchgear isolated from ground and where a non-shielded flexible cable is desired. These cables are capable of operating continuously at a conductor temperature not in excess of 90°C. <br> <br> This cable is rated up to 40KV and is not UL listed. See Table 2 for installation guidelines

Specifications

Select a set of products below for more information:
Cond. Size (AWG/Kcmil) Conductor Number Cond. Strands Diameter Over Conductor (in) (cm) Insulation Thickness (mils) (mm) Diameter Over Insulation (in) (cm) Ground (No. x AWG) Ground Check Size Ground Check Strands Ground Insulation Thickness (mils) (mm) Inner Jacket Thickness (mils) (mm) Diameter Over Armor (in) (cm) Jacket Thickness (mils) (mm) Approx. OD (in) (cm) Approx. Weight (lbs/1000') (kgs/km)
569424
2 2
0.0 0.0
168 168
0.290 0.74
210 5.33
0.753 1.91
177 263
569423
1/0 1/0
1.0 1.0
259 259
0.379 0.96
210 5.33
0.840 2.13
548 816
569425
2/0 2/0
1.0 1.0
324 324
0.400 1.02
220 5.59
0.883 2.24
674 1003
569487
4/0 4/0
1.0 1.0
532 532
0.530 1.35
210 5.33
0.979 2.49
960 1429
569427
350 350
1.0 1.0
893 893
0.670 1.70
230 5.84
1.160 2.95
1475 2195
569428
500 500
1.0 1.0
1221 1221
0.858 2.18
230 5.84
1.350 3.43
1970 2932
Cond. Size (AWG/Kcmil) DC Resistance @ 25C (ohms/1000') (ohms/km) AC Resistance @ 75C (ohms/1000') (ohms/km) Capacitive Reactance (Mohms x 1000ft) (Mohms x km) Inductive Reactance (ohms/1000') (ohms/km) Rated Strength (lbs) (kg) Max Pull Tension (lbs) (kg) Min. Bend Radius (in) (cm) In Air Ampacity @ 60C (amps) In Air Ampacity @ 75C (amps) In Air Ampacity @ 90C (amps) In Air Ampacity @ 105C (amps) Raceway Ampacity @ 75C (amps) Raceway Ampacity @ 90C (amps)
569424
2 2
0.172 0.26
0.207 0.31
0.045 0.07
530 240.40
115 115
130 130
569423
1/0 1/0
0.109 0.16
0.131 0.19
0.044 0.07
844 382.83
150 150
170 170
569425
2/0 2/0
0.087 0.13
0.104 0.15
0.043 0.06
1064 482.62
175 175
195 195
569487
4/0 4/0
0.055 0.08
0.067 0.10
0.041 0.06
1692 767.48
230 230
260 260
569427
350 350
0.033 0.05
0.042 0.06
0.04 0.06
2800 1270.06
310 310
350 350
569428
500 500
0.023 0.03
0.031 0.05
0.039 0.06
4000 1814.37
380 380
430 430

Standards & References

  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors

Construction

  1. Conductor: Flexible rope lay stranded annealed bare or tinned copper
  2. Conductor Shield: Nylon semi-conducting tape, helically applied
  3. Insulation: Heat, moisture, and ozone resistant Ethylene Propylene Rubber(EPR)