Southwire Type W cable is a heavy-duty industrial cable for use in flexible, portable, and extra-hard usage applications per NEC Article 400. Suitable for continuous submersion in water – ideal for submersible pumps. Also suitable for use in light to medium-duty mining applications. Sunlight and oil resistant. Highly flexible and easy to work with in cold conditions. Not for use as permanent building wiring. Meets FT-5 Flame Test. cUL listing on select items only.
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Ground Check Size | Ground Check Strands | Ground Insulation Thickness (mils) (mm) | Inner Jacket Thickness (mils) (mm) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Approx. Weight (lbs/1000') (kgs/km) | |
571259 |
8
8
|
5.0
5.0
|
71
71
|
0.145
0.37
|
60
1.52
|
|
|
|
|
|
|
|
155
3.94
|
1.056
2.68
|
665
990
|
570257 |
6
6
|
5.0
5.0
|
65
65
|
0.186
0.47
|
60
1.52
|
|
|
|
|
|
|
|
140
3.56
|
1.210
3.07
|
881
1311
|
570255 |
4
4
|
5.0
5.0
|
112
112
|
0.235
0.60
|
60
1.52
|
|
|
|
|
|
|
|
155
3.94
|
1.399
3.55
|
1347
2005
|
571483 |
2
2
|
5.0
5.0
|
168
168
|
0.290
0.74
|
60
1.52
|
|
|
|
|
|
|
|
170
4.32
|
1.605
4.08
|
1990
2961
|
570097 |
1/0
1/0
|
5.0
5.0
|
259
259
|
0.379
0.96
|
80
2.03
|
|
|
|
|
|
|
|
260
6.60
|
2.041
5.18
|
3075
4576
|
571470 |
2/0
2/0
|
5.0
5.0
|
324
324
|
0.400
1.02
|
80
2.03
|
|
|
|
|
|
|
|
205
5.21
|
2.072
5.26
|
3336
4965
|
571472 |
3/0
3/0
|
5.0
5.0
|
418
418
|
0.480
1.22
|
80
2.03
|
|
|
|
|
|
|
|
205
5.21
|
2.153
5.47
|
3893
5793
|
570253 |
4/0
4/0
|
5.0
5.0
|
532
532
|
0.530
1.35
|
80
2.03
|
|
|
|
|
|
|
|
220
5.59
|
2.394
6.08
|
5313
7907
|
Cond. Size (AWG/Kcmil) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Capacitive Reactance (Mohms x 1000ft) (Mohms x km) | Inductive Reactance (ohms/1000') (ohms/km) | Rated Strength (lbs) (kg) | Max Pull Tension (lbs) (kg) | Min. Bend Radius (in) (cm) | In Air Ampacity @ 60C (amps) | In Air Ampacity @ 75C (amps) | In Air Ampacity @ 90C (amps) | In Air Ampacity @ 105C (amps) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
571259 |
8
8
|
0.679
1.01
|
0.818
1.22
|
|
0.052
0.08
|
|
|
5.2
13.21
|
38
38
|
46
46
|
52
52
|
|
|
|
570257 |
6
6
|
0.435
0.65
|
0.524
0.78
|
|
0.051
0.08
|
|
|
6.0
15.24
|
50
50
|
62
62
|
70
70
|
|
|
|
570255 |
4
4
|
0.274
0.41
|
0.33
0.49
|
|
0.048
0.07
|
|
|
6.9
17.53
|
67
67
|
81
81
|
91
91
|
|
|
|
571483 |
2
2
|
0.172
0.26
|
0.207
0.31
|
|
0.045
0.07
|
|
|
8.0
20.32
|
90
90
|
106
106
|
122
122
|
|
|
|
570097 |
1/0
1/0
|
0.109
0.16
|
0.131
0.19
|
|
0.044
0.07
|
|
|
12.2
30.99
|
121
121
|
145
145
|
164
164
|
|
|
|
571470 |
2/0
2/0
|
0.087
0.13
|
0.104
0.15
|
|
0.043
0.06
|
|
|
12.4
31.50
|
139
139
|
166
166
|
190
190
|
|
|
|
571472 |
3/0
3/0
|
0.069
0.10
|
0.083
0.12
|
|
0.042
0.06
|
|
|
12.9
32.77
|
161
161
|
193
193
|
219
219
|
|
|
|
570253 |
4/0
4/0
|
0.055
0.08
|
0.067
0.10
|
|
0.041
0.06
|
|
|
14.3
36.32
|
186
186
|
222
222
|
253
253
|
|
|
|