Southwire’s Remote Power and Drill cord cable is a heavy-duty cable for use where limited flexing and rugged use are re- quired. For use in stationary heavy duty pumps or long-wall lighting application. Designed for long service life in wet or dry locations in underground mines. The cable is sunlight resistant, crush resistant, and abrasion resistant. Also suitable for continuous submersion in water. Embossed print legend for easy cable identification.
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Ground Check Size | Ground Check Strands | Ground Insulation Thickness (mils) (mm) | Inner Jacket Thickness (mils) (mm) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Approx. Weight (lbs/1000') (kgs/km) | |
571415 |
14
14
|
4.0
4.0
|
41
41
|
0.073
0.19
|
45
1.14
|
0.167
0.42
|
|
|
|
|
65
1.65
|
|
85
2.16
|
0.710
1.80
|
278
414
|
571402 |
12
12
|
5.0
5.0
|
65
65
|
0.094
0.24
|
45
1.14
|
0.184
0.47
|
|
|
|
|
65
1.65
|
|
100
2.54
|
0.830
2.11
|
398
592
|
571731 |
12
12
|
6.0
6.0
|
65
65
|
0.094
0.24
|
45
1.14
|
0.184
0.47
|
|
|
|
|
65
1.65
|
|
100
2.54
|
0.890
2.26
|
458
682
|
571710 |
10
10
|
5.0
5.0
|
104
104
|
0.117
0.30
|
45
1.14
|
0.205
0.52
|
|
|
|
|
65
1.65
|
|
95
2.41
|
0.900
2.29
|
492
732
|
583920 |
8
8
|
5.0
5.0
|
71
71
|
0.153
0.39
|
60
1.52
|
0.275
0.70
|
|
|
|
|
65
1.65
|
|
95
2.41
|
1.090
2.77
|
716
1066
|
Cond. Size (AWG/Kcmil) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Capacitive Reactance (Mohms x 1000ft) (Mohms x km) | Inductive Reactance (ohms/1000') (ohms/km) | Rated Strength (lbs) (kg) | Max Pull Tension (lbs) (kg) | Min. Bend Radius (in) (cm) | In Air Ampacity @ 60C (amps) | In Air Ampacity @ 75C (amps) | In Air Ampacity @ 90C (amps) | In Air Ampacity @ 105C (amps) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
571415 |
14
14
|
2.814
4.19
|
3.555
5.29
|
|
0.041
0.06
|
28
12.70
|
|
5.6
14.22
|
|
|
15
15
|
|
|
|
571402 |
12
12
|
1.774
2.64
|
2.241
3.33
|
|
0.037
0.06
|
44
19.96
|
|
6.6
16.76
|
|
|
20
20
|
|
|
|
571731 |
12
12
|
1.774
2.64
|
2.241
3.33
|
|
0.037
0.06
|
44
19.96
|
|
7.1
18.03
|
|
|
20
20
|
|
|
|
571710 |
10
10
|
1.111
1.65
|
1.404
2.09
|
|
0.035
0.05
|
70
31.75
|
|
7.2
18.29
|
|
|
25
25
|
|
|
|
583920 |
8
8
|
0.715
1.06
|
0.903
1.34
|
|
0.035
0.05
|
112
50.80
|
|
8.7
22.10
|
|
|
35
35
|
|
|
|