SPEC47812 3/C CU 8KV 100% XLP/PVC RHINOPOWER<sup style="font-size:0.6em;">TM</sup> Type MP-GC. MSHA Approved

Class B Copper conductors, Cross-Linked Polyethylene (XLP) 100% Insulation Level, Copper Tape Shield, Polyvinyl Chloride (PVC) Jacket, 90°C

Download Category Specifications
PDF Excel Table

Application

RHINOPOWER<sup>TM</sup> Type MP-GC mine power feeder cable is a heavy-duty power cable for use in stationary horizontal HV mine power distribution circuits, for permanent or semi-portable applications with power transmission in deep mines, surface mines, open pits, tunnels, in conduit or duct (not to exceed max rated voltage), and suitable for direct burial in wet or dry locations. For vertical drop requirements consult with factory application specialist.

Specifications

Select a set of products below for more information:
Cond. Size (AWG/Kcmil) Conductor Number Cond. Strands Diameter Over Conductor (in) (cm) Insulation Thickness (mils) (mm) Diameter Over Insulation (in) (cm) Ground (No. x AWG) Ground Check Size Ground Check Strands Ground Insulation Thickness (mils) (mm) Inner Jacket Thickness (mils) (mm) Diameter Over Armor (in) (cm) Jacket Thickness (mils) (mm) Approx. OD (in) (cm) Approx. Weight (lbs/1000') (kgs/km)
571724
2 2
3.0 3.0
7 7
0.268 0.68
115 2.92
0.528 1.34
8 8
115 2.92
1.565 3.98
1637 2436
569948
4/0 4/0
3.0 3.0
19 19
0.474 1.20
115 2.92
0.735 1.87
8 8
145 3.68
2.120 5.38
3188 4744
587657
500 500
3.0 3.0
37 37
0.735 1.87
115 2.92
0.996 2.53
8 8
140 3.56
2.750 6.99
7880 11727
Cond. Size (AWG/Kcmil) DC Resistance @ 25C (ohms/1000') (ohms/km) AC Resistance @ 75C (ohms/1000') (ohms/km) Capacitive Reactance (Mohms x 1000ft) (Mohms x km) Inductive Reactance (ohms/1000') (ohms/km) Rated Strength (lbs) (kg) Max Pull Tension (lbs) (kg) Min. Bend Radius (in) (cm) In Air Ampacity @ 60C (amps) In Air Ampacity @ 75C (amps) In Air Ampacity @ 90C (amps) In Air Ampacity @ 105C (amps) Raceway Ampacity @ 75C (amps) Raceway Ampacity @ 90C (amps)
571724
2 2
0.162 0.24
0.204 0.30
0.046 0.07
0.037 0.06
453 205.48
18.7 47.50
159 159
569948
4/0 4/0
0.051 0.08
0.065 0.10
0.029 0.04
0.032 0.05
1447 656.35
25.4 64.52
321 321
587657
500 500
0.022 0.03
0.03 0.04
0.02 0.03
0.029 0.04
3420 1551.28
33.0 83.82
536 536

Standards & References

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B496 Compact Round Concentric-lay-standard copper
  • ICEA S-75-381 Portable and Power Feeder Cables for Use in Mines
  • MSHA Approved

Construction

  1. Conductor: Class B compact stranded bare copper per ASTM B3 and ASTM B496
  2. Conductor Shield: Semi-conducting cross-linked copolymer
  3. Insulation: Ethylene Propylene Rubber (EPR) 100% and 133% Insulation Level
  4. Insulation Shield: Strippable semi-conducting cross-linked copolymer
  5. Copper Tape Shield: Helically wrapped 5 mil copper tape with 25% overlap
  6. Grounding Conductors: Two Class B compressed stranded bare copper per ASTM B3 and ASTM B8
  7. Ground Check: Class B compressed stranded bare copper per ASTM B3 and ASTM B8 with yellow high strength, polypropylene insulation
  8. Filler: Rubber Fillers as needed
  9. Reinforcement: Tape and Reinforcing twine applied over the core for improved mechanical integrity and ease of stripping
  10. Jacket: Black, mold cured, single layer, flame resistant, thermosetting Chlorinated Polyethylene (CPE). Alternate jacket colors available
  11. Reflective Stripe: Highly visible reflective stripe embedded into the outer jacket to increase safety and help prevent cable runover (optional, contact your sales representative for part number)