Southwire’s 2000 Volt power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.
Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | |
More Options |
12 AWG
12 AWG
|
0
0
|
19
19
|
0.088
0.22
|
75
1.91
|
|
0.243
0.62
|
20
30
|
39
58
|
More Options |
10 AWG
10 AWG
|
1
1
|
19
19
|
0.113
0.29
|
75
1.91
|
75
1.91
|
0.263
0.67
|
32
48
|
53
79
|
More Options |
8 AWG
8 AWG
|
1
1
|
19
19
|
0.141
0.36
|
85
2.16
|
|
0.313
0.80
|
50
74
|
79
118
|
More Options |
6 AWG
6 AWG
|
1
1
|
19
19
|
0.177
0.45
|
85
2.16
|
85
2.16
|
0.349
0.89
|
81
121
|
114
170
|
More Options |
4 AWG
4 AWG
|
1
1
|
19
19
|
0.225
0.57
|
85
2.16
|
|
0.396
1.01
|
128
190
|
168
250
|
More Options |
1/0 AWG
1/0 AWG
|
1
1
|
19
19
|
0.361
0.92
|
105
2.67
|
|
0.570
1.45
|
326
485
|
396
589
|
More Options |
2/0 AWG
2/0 AWG
|
1
1
|
19
19
|
0.405
1.03
|
105
2.67
|
|
0.614
1.56
|
410
610
|
488
726
|
More Options |
500 KCMIL
500 KCMIL
|
1
1
|
37
37
|
0.789
2.00
|
120
3.05
|
|
1.006
2.56
|
1543
2296
|
1685
2508
|
*VW-1 Rated
Cond. Size | Conductor Number | Min. Bend Radius (in) (cm) | Max Pull Tension (lbs) (kg) | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | Allowable Ampacity Raceway 75C | Allowable Ampacity Raceway 90C | |
More Options |
12 AWG
12 AWG
|
0
0
|
1.0
2.54
|
|
1.662
2.47
|
2.002
2.98
|
0.054
0.08
|
25
25
|
30
30
|
More Options |
10 AWG
10 AWG
|
1
1
|
1.1
2.79
|
|
1.040
1.55
|
1.253
1.86
|
0.050
0.07
|
35
35
|
40
40
|
More Options |
8 AWG
8 AWG
|
1
1
|
1.3
3.30
|
132
59.87
|
0.653
0.97
|
0.786
1.17
|
0.052
0.08
|
50
50
|
55
55
|
More Options |
6 AWG
6 AWG
|
1
1
|
1.4
3.56
|
209
94.80
|
0.411
0.61
|
0.495
0.74
|
0.051
0.08
|
65
65
|
75
75
|
More Options |
4 AWG
4 AWG
|
1
1
|
1.6
4.06
|
333
151.05
|
0.258
0.38
|
0.310
0.46
|
0.048
0.07
|
85
85
|
95
95
|
More Options |
1/0 AWG
1/0 AWG
|
1
1
|
2.3
5.84
|
844
382.83
|
0.102
0.15
|
0.122
0.18
|
0.044
0.07
|
150
150
|
170
170
|
More Options |
2/0 AWG
2/0 AWG
|
1
1
|
2.5
6.35
|
1064
482.62
|
0.081
0.12
|
0.097
0.14
|
0.043
0.06
|
175
175
|
195
195
|
More Options |
500 KCMIL
500 KCMIL
|
1
1
|
5.0
12.70
|
4000
1814.37
|
0.022
0.03
|
0.029
0.04
|
0.039
0.06
|
380
380
|
430
430
|
Ampacities based upon 2023 NEC Table 310.16. See NEC sections 310.15 and 110.14(C) for additional requirements.
Inductive Reactance is based on non-ferrous conduit with one diameter spacing center-to-center.
Size | Black | White | Red | Green | Green/Yellow |
AWG/Kcmil
AWG/Kcmil
|
![]() |
![]() |
![]() |
![]() |
![]() |
14
14
|
597961
597961
|
|
|
|
|
12
12
|
597958 |
596376
596376
|
596377
596377
|
|
|
10
10
|
579962 |
583665
583665
|
583687
583687
|
|
|
1/0
1/0
|
569043 |
|
|
|
677562
677562
|
2/0
2/0
|
569044 |
|
|
|
|
3/0
3/0
|
569045
569045
|
|
|
|
|
4/0
4/0
|
569047
569047
|
|
|
|
|
250
250
|
679559
679559
|
|
|
|
|
300
300
|
653096
653096
|
599400
599400
|
599401
599401
|
|
|
350
350
|
590138
590138
|
|
|
|
|
400
400
|
587813
587813
|
|
|
|
|
500
500
|
578324 |
|
|
|
|
600
600
|
672530
672530
|
|
|
|
|