Suitable for installation in Cable Trays, Underground Duct Banks - As per CE Code limitations (see Rule 12-2202) for grounding and bonding applications. Standard colour is black. Some sizes may be availabe in white, red, blue, yellow, brown, orange or grey. Green DuragroundTM also available.
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Drain Wire | Diameter Over Shield (in) (cm) | Inner Jacket Thickness (mils) (mm) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | |
649139 |
1/0
1/0
|
1.0
1.0
|
19
19
|
0.361
0.92
|
80
2.03
|
|
|
|
|
|
|
|
0.528
1.34
|
326
485
|
|
395
588
|
649088 |
2/0
2/0
|
1.0
1.0
|
19
19
|
0.405
1.03
|
80
2.03
|
|
|
|
|
|
|
|
0.572
1.45
|
410
610
|
|
487
725
|
649148 |
3/0
3/0
|
1.0
1.0
|
19
19
|
0.456
1.16
|
80
2.03
|
|
|
|
|
|
|
|
0.622
1.58
|
518
771
|
|
602
896
|
649097 |
4/0
4/0
|
1.0
1.0
|
19
19
|
0.512
1.30
|
80
2.03
|
|
|
|
|
|
|
|
0.666
1.69
|
653
972
|
|
745
1109
|
649045 |
500
500
|
1.0
1.0
|
37
37
|
0.789
2.00
|
95
2.41
|
|
|
|
|
|
|
|
0.966
2.45
|
1543
2296
|
|
1705
2537
|
649048 |
750
750
|
1.0
1.0
|
61
61
|
0.968
2.46
|
110
2.79
|
|
|
|
|
|
|
|
1.200
3.05
|
2315
3445
|
|
2549
3793
|
649130 |
1000
1000
|
1.0
1.0
|
61
61
|
1.117
2.84
|
110
2.79
|
|
|
|
|
|
|
|
1.349
3.43
|
3087
4594
|
|
3354
4991
|
Cond. Size (AWG/Kcmil) | Conductor Number | Min. Bend Radius (in) (cm) | Max Pull Tension (lbs) (kg) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Capacitive Reactance (Mohms x 1000ft) (Mohms x km) | Inductive Reactance (ohms/1000') (ohms/km) | Shield Short Circuit Current 6 Cycles (amps) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
649139 |
1/0
1/0
|
1.0
1.0
|
2.1
5.33
|
844
382.83
|
0.102
0.15
|
0.122
0.18
|
|
0.044
0.07
|
|
150
150
|
170
170
|
649088 |
2/0
2/0
|
1.0
1.0
|
2.2
5.59
|
1064
482.62
|
0.081
0.12
|
0.097
0.14
|
|
0.043
0.06
|
|
175
175
|
195
195
|
649148 |
3/0
3/0
|
1.0
1.0
|
2.4
6.10
|
1342
608.72
|
0.064
0.10
|
0.078
0.12
|
|
0.042
0.06
|
|
200
200
|
225
225
|
649097 |
4/0
4/0
|
1.0
1.0
|
2.6
6.60
|
1692
767.48
|
0.051
0.08
|
0.062
0.09
|
|
0.041
0.06
|
|
230
230
|
260
260
|
649045 |
500
500
|
1.0
1.0
|
3.8
9.65
|
4000
1814.37
|
0.022
0.03
|
0.029
0.04
|
|
0.039
0.06
|
|
380
380
|
430
430
|
649048 |
750
750
|
1.0
1.0
|
6.0
15.24
|
6000
2721.55
|
0.014
0.02
|
0.022
0.03
|
|
0.038
0.06
|
|
475
475
|
535
535
|
649130 |
1000
1000
|
1.0
1.0
|
6.7
17.02
|
8000
3628.74
|
0.011
0.02
|
0.018
0.03
|
|
0.037
0.06
|
|
545
545
|
615
615
|