Southwire’s 600 Volt power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. CT Rated 1/0 and Larger - Silicone Free
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Drain Wire | Diameter Over Shield (in) (cm) | Inner Jacket Thickness (mils) (mm) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | |
890660 |
8
8
|
0.0
0.0
|
7
7
|
0.141
0.36
|
45
1.14
|
|
|
|
|
|
|
15
0.38
|
0.268
0.68
|
50
74
|
|
74
110
|
890659 |
6
6
|
1.0
1.0
|
7
7
|
0.177
0.45
|
45
1.14
|
|
|
|
|
|
|
30
0.76
|
0.338
0.86
|
81
121
|
|
119
177
|
551088 |
2
2
|
1.0
1.0
|
7
7
|
0.282
0.72
|
45
1.14
|
|
|
|
|
|
|
30
0.76
|
0.438
1.11
|
204
304
|
|
258
384
|
561561 |
1/0
1/0
|
1.0
1.0
|
19
19
|
0.361
0.92
|
55
1.40
|
|
|
|
|
|
|
45
1.14
|
0.575
1.46
|
326
485
|
|
418
622
|
561560 |
2/0
2/0
|
1.0
1.0
|
19
19
|
0.405
1.03
|
55
1.40
|
|
|
|
|
|
|
45
1.14
|
0.617
1.57
|
410
610
|
|
511
760
|
581799 |
3/0
3/0
|
1.0
1.0
|
19
19
|
0.456
1.16
|
55
1.40
|
|
|
|
|
|
|
45
1.14
|
0.669
1.70
|
518
771
|
|
628
935
|
561556 |
4/0
4/0
|
1.0
1.0
|
19
19
|
0.512
1.30
|
55
1.40
|
|
|
|
|
|
|
45
1.14
|
0.711
1.81
|
653
972
|
|
770
1146
|
561553 |
350
350
|
1.0
1.0
|
37
37
|
0.661
1.68
|
65
1.65
|
|
|
|
|
|
|
65
1.65
|
0.916
2.33
|
1080
1607
|
|
1280
1905
|
890658 |
500
500
|
1.0
1.0
|
37
37
|
0.789
2.00
|
65
1.65
|
|
|
|
|
|
|
65
1.65
|
1.041
2.64
|
1543
2296
|
|
1775
2641
|
551091 |
750
750
|
1.0
1.0
|
61
61
|
0.968
2.46
|
80
2.03
|
|
|
|
|
|
|
65
1.65
|
1.246
3.16
|
2315
3445
|
|
2625
3906
|
Cond. Size (AWG/Kcmil) | Conductor Number | Min. Bend Radius (in) (cm) | Max Pull Tension (lbs) (kg) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Capacitive Reactance (Mohms x 1000ft) (Mohms x km) | Inductive Reactance (ohms/1000') (ohms/km) | Shield Short Circuit Current 6 Cycles (amps) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
890660 |
8
8
|
0.0
0.0
|
1.0
2.54
|
132
59.87
|
0.653
0.97
|
0.786
1.17
|
|
0.052
0.08
|
|
50
50
|
55
55
|
890659 |
6
6
|
1.0
1.0
|
1.3
3.30
|
209
94.80
|
0.411
0.61
|
0.495
0.74
|
|
0.051
0.08
|
|
65
65
|
75
75
|
551088 |
2
2
|
1.0
1.0
|
1.7
4.32
|
530
240.40
|
0.162
0.24
|
0.195
0.29
|
|
0.045
0.07
|
|
115
115
|
130
130
|
561561 |
1/0
1/0
|
1.0
1.0
|
2.3
5.84
|
844
382.83
|
0.102
0.15
|
0.122
0.18
|
|
0.044
0.07
|
|
150
150
|
170
170
|
561560 |
2/0
2/0
|
1.0
1.0
|
2.4
6.10
|
1064
482.62
|
0.081
0.12
|
0.097
0.14
|
|
0.043
0.06
|
|
175
175
|
195
195
|
581799 |
3/0
3/0
|
1.0
1.0
|
2.6
6.60
|
1342
608.72
|
0.064
0.10
|
0.078
0.12
|
|
0.042
0.06
|
|
200
200
|
225
225
|
561556 |
4/0
4/0
|
1.0
1.0
|
2.8
7.11
|
1692
767.48
|
0.051
0.08
|
0.062
0.09
|
|
0.041
0.06
|
|
230
230
|
260
260
|
561553 |
350
350
|
1.0
1.0
|
3.6
9.14
|
2800
1270.06
|
0.031
0.05
|
0.039
0.06
|
|
0.04
0.06
|
|
310
310
|
350
350
|
890658 |
500
500
|
1.0
1.0
|
5.2
13.21
|
4000
1814.37
|
0.022
0.03
|
0.029
0.04
|
|
0.039
0.06
|
|
380
380
|
430
430
|
551091 |
750
750
|
1.0
1.0
|
6.2
15.75
|
6000
2721.55
|
0.014
0.02
|
0.022
0.03
|
|
0.038
0.06
|
|
475
475
|
535
535
|