Southwire’s 600 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. VW-1 rated - Sunlight Resistant - Oil Resistant - For Direct Burial - Silicone Free
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Color | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Min. Bend Radius (in) (cm) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
599457 |
14
14
|
3.0
3.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.388
0.99
|
37
55
|
|
86
128
|
2.631
3.92
|
3.17
4.72
|
1.6
4.06
|
20
20
|
25
25
|
599458 |
14
14
|
4.0
4.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.423
1.07
|
50
74
|
|
107
159
|
2.631
3.92
|
3.17
4.72
|
1.7
4.32
|
16
16
|
20
20
|
599459 |
14
14
|
5.0
5.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.461
1.17
|
62
92
|
|
129
192
|
2.631
3.92
|
3.17
4.72
|
1.8
4.57
|
16
16
|
20
20
|
595479 |
14
14
|
7.0
7.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.502
1.28
|
87
129
|
|
170
253
|
2.631
3.92
|
3.17
4.72
|
2.0
5.08
|
14
14
|
17
17
|
599460 |
14
14
|
9.0
9.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.616
1.56
|
112
167
|
|
232
345
|
2.631
3.92
|
3.17
4.72
|
2.5
6.35
|
14
14
|
17
17
|
599461 |
14
14
|
12.0
12.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.692
1.76
|
150
223
|
|
299
445
|
2.631
3.92
|
3.17
4.72
|
2.8
7.11
|
10
10
|
12
12
|
595475 |
14
14
|
19.0
19.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.804
2.04
|
237
353
|
|
434
646
|
2.631
3.92
|
3.17
4.72
|
3.2
8.13
|
10
10
|
12
12
|
595635 |
12
12
|
2.0
2.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.466
1.18
|
40
60
|
|
86
128
|
1.662
2.47
|
2.002
2.98
|
1.9
4.83
|
25
25
|
30
30
|
595472 |
12
12
|
3.0
3.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.466
1.18
|
61
91
|
|
115
171
|
1.662
2.47
|
2.002
2.98
|
1.9
4.83
|
25
25
|
30
30
|
595636 |
12
12
|
4.0
4.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.466
1.18
|
81
121
|
|
148
220
|
1.662
2.47
|
2.002
2.98
|
1.9
4.83
|
20
20
|
24
24
|
592111 |
12
12
|
5.0
5.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.543
1.38
|
101
150
|
|
198
295
|
1.662
2.47
|
2.002
2.98
|
2.2
5.59
|
20
20
|
24
24
|
596919 |
12
12
|
9.0
9.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.589
1.50
|
183
272
|
|
319
475
|
1.662
2.47
|
2.002
2.98
|
2.4
6.10
|
17
17
|
21
21
|
595477 |
12
12
|
12.0
12.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.466
1.18
|
244
363
|
|
410
610
|
1.662
2.47
|
2.002
2.98
|
1.9
4.83
|
12
12
|
15
15
|
595632 |
10
10
|
2.0
2.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.466
1.18
|
64
95
|
|
116
173
|
1.04
1.55
|
1.253
1.86
|
1.9
4.83
|
35
35
|
40
40
|
595556 |
10
10
|
3.0
3.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.478
1.21
|
97
144
|
|
161
240
|
1.04
1.55
|
1.253
1.86
|
1.9
4.83
|
35
35
|
40
40
|
595633 |
10
10
|
4.0
4.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.556
1.41
|
129
192
|
|
223
332
|
1.04
1.55
|
1.253
1.86
|
2.2
5.59
|
28
28
|
32
32
|
645726 |
10
10
|
12.0
12.0
|
7
7
|
|
|
30
0.76
|
|
|
|
80
2.03
|
0.466
1.18
|
388
577
|
|
615
915
|
1.04
1.55
|
1.253
1.86
|
1.9
4.83
|
17
17
|
20
20
|