Southwire Type W cable is a heavy-duty industrial cable for use in flexible, portable, and extra-hard usage applications per Article NEC 400. Suitable for continuous submersion in water – ideal for submersible pumps. Also suitable for use in light to medium-duty mining applications. Sunlight and oil resistant. Highly flexible and easy to work with in cold conditions. Not for use as perminant building wiring. Meets FT-5 Flame Test.
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Ground Check Size | Ground Check Strands | Ground Insulation Thickness (mils) (mm) | Inner Jacket Thickness (mils) (mm) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Approx. Weight (lbs/1000') (kgs/km) | |
558152 |
8
8
|
4.0
4.0
|
71
71
|
0.145
0.37
|
60
1.52
|
|
|
|
|
|
|
|
155
3.94
|
0.988
2.51
|
577
859
|
558154 |
6
6
|
4.0
4.0
|
65
65
|
0.186
0.47
|
60
1.52
|
|
|
|
|
|
|
|
145
3.68
|
1.120
2.84
|
748
1113
|
558156 |
4
4
|
4.0
4.0
|
112
112
|
0.235
0.60
|
60
1.52
|
|
|
|
|
|
|
|
125
3.18
|
1.223
3.11
|
1054
1569
|
558157 |
2
2
|
4.0
4.0
|
168
168
|
0.290
0.74
|
60
1.52
|
|
|
|
|
|
|
|
145
3.68
|
1.465
3.72
|
1766
2628
|
570102 |
1
1
|
4.0
4.0
|
224
224
|
0.300
0.76
|
80
2.03
|
|
|
|
|
|
|
|
145
3.68
|
1.654
4.20
|
1985
2954
|
558158 |
1/0
1/0
|
4.0
4.0
|
259
259
|
0.379
0.96
|
80
2.03
|
|
|
|
|
|
|
|
165
4.19
|
1.729
4.39
|
2249
3347
|
558159 |
2/0
2/0
|
4.0
4.0
|
324
324
|
0.400
1.02
|
80
2.03
|
|
|
|
|
|
|
|
225
5.72
|
1.874
4.76
|
2764
4113
|
560068 |
3/0
3/0
|
4.0
4.0
|
418
418
|
0.480
1.22
|
80
2.03
|
|
|
|
|
|
|
|
155
3.94
|
1.890
4.80
|
3226
4801
|
560069 |
4/0
4/0
|
4.0
4.0
|
532
532
|
0.530
1.35
|
80
2.03
|
|
|
|
|
|
|
|
235
5.97
|
2.199
5.59
|
3979
5921
|
570250 |
350
350
|
4.0
4.0
|
893
893
|
0.670
1.70
|
95
2.41
|
|
|
|
|
|
|
|
284
7.21
|
2.968
7.54
|
7114
10587
|
Cond. Size (AWG/Kcmil) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Capacitive Reactance (Mohms x 1000ft) (Mohms x km) | Inductive Reactance (ohms/1000') (ohms/km) | Rated Strength (lbs) (kg) | Max Pull Tension (lbs) (kg) | Min. Bend Radius (in) (cm) | In Air Ampacity @ 60C (amps) | In Air Ampacity @ 75C (amps) | In Air Ampacity @ 90C (amps) | In Air Ampacity @ 105C (amps) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
558152 |
8
8
|
0.679
1.01
|
0.818
1.22
|
|
0.052
0.08
|
|
|
3.9
9.91
|
38
38
|
46
46
|
52
52
|
|
|
|
558154 |
6
6
|
0.435
0.65
|
0.524
0.78
|
|
0.051
0.08
|
|
|
5.6
14.22
|
50
50
|
62
62
|
70
70
|
|
|
|
558156 |
4
4
|
0.274
0.41
|
0.33
0.49
|
|
0.048
0.07
|
|
|
6.1
15.49
|
67
67
|
81
81
|
91
91
|
|
|
|
558157 |
2
2
|
0.172
0.26
|
0.207
0.31
|
|
0.045
0.07
|
|
|
7.3
18.54
|
90
90
|
106
106
|
122
122
|
|
|
|
570102 |
1
1
|
0.137
0.20
|
0.164
0.24
|
|
0.046
0.07
|
|
|
8.2
20.83
|
105
105
|
125
125
|
142
142
|
|
|
|
558158 |
1/0
1/0
|
0.109
0.16
|
0.131
0.19
|
|
0.044
0.07
|
|
|
8.6
21.84
|
121
121
|
145
145
|
164
164
|
|
|
|
558159 |
2/0
2/0
|
0.087
0.13
|
0.104
0.15
|
|
0.043
0.06
|
|
|
9.3
23.62
|
139
139
|
166
166
|
190
190
|
|
|
|
560068 |
3/0
3/0
|
0.069
0.10
|
0.083
0.12
|
|
0.042
0.06
|
|
|
9.4
23.88
|
201
201
|
241
241
|
274
274
|
|
|
|
560069 |
4/0
4/0
|
0.055
0.08
|
0.067
0.10
|
|
0.041
0.06
|
|
|
13.1
33.27
|
186
186
|
222
222
|
253
253
|
|
|
|
570250 |
350
350
|
0.033
0.05
|
0.042
0.06
|
|
0.04
0.06
|
|
|
17.8
45.21
|
254
254
|
305
305
|
346
346
|
|
|
|