SPEC44140 3/C CU 2000V EPDM/CPE Type G-GC Industrial Grade Cable 90°C. MSHA Approved

Flexible Copper conductors, Ethylene Propylene Diene Monomer (EPDM) insulation, Single Layer Chlorinated Polyethylene (CPE) Jacket

Download Category Specifications
PDF Excel Table

Application

Southwire Type G-GC cable is a heavy-duty industrial cable for use in flexible, portable, and extra-hard usage applications where equipment grounding is required per NEC Article 400. Suitable for continuous submersion in water – ideal for submersible pumps, marine application. Also suitable for use in light to medium-duty mining applications. Sunlight and oil resistant. Highly flexible and easy to work with in cold conditions. Not for use as permanent building wiring. Meets FT-5 Flame Test. cUL Listed.

Specifications

Select a set of products below for more information:
Cond. Size (AWG/Kcmil) Conductor Number Cond. Strands Diameter Over Conductor (in) (cm) Insulation Thickness (mils) (mm) Diameter Over Insulation (in) (cm) Ground (No. x AWG) Ground Check Size Ground Check Strands Ground Insulation Thickness (mils) (mm) Inner Jacket Thickness (mils) (mm) Diameter Over Armor (in) (cm) Jacket Thickness (mils) (mm) Approx. OD (in) (cm) Approx. Weight (lbs/1000') (kgs/km)
560537
8 8
3.0 3.0
71 71
0.145 0.37
60 1.52
1x10 1x10
145 3.68
0.980 2.49
655 975
558168
6 6
3.0 3.0
65 65
0.186 0.47
60 1.52
1x10 1x10
145 3.68
1.055 2.68
815 1213
558169
4 4
3.0 3.0
112 112
0.235 0.60
60 1.52
1x8 1x8
130 3.30
1.172 2.98
1116 1661
558170
2 2
3.0 3.0
168 168
0.290 0.74
60 1.52
1x8 1x8
165 4.19
1.289 3.27
1405 2091
570098
1 1
3.0 3.0
224 224
0.300 0.76
80 2.03
1x8 1x8
145 3.68
1.455 3.70
1733 2579
558165
1/0 1/0
3.0 3.0
259 259
0.379 0.96
80 2.03
1x8 1x8
185 4.70
1.660 4.22
2096 3119
558166
2/0 2/0
3.0 3.0
324 324
0.400 1.02
80 2.03
1x8 1x8
215 5.46
1.704 4.33
2519 3749
560065
3/0 3/0
3.0 3.0
418 418
0.480 1.22
80 2.03
1x8 1x8
205 5.21
1.830 4.65
3015 4487
558167
4/0 4/0
3.0 3.0
532 532
0.530 1.35
80 2.03
1x8 1x8
175 4.45
1.970 5.00
3710 5521
570239
250 250
3.0 3.0
608 608
0.605 1.54
95 2.41
1x8 1x8
260 6.60
2.284 5.80
4691 6981
559281
350 350
3.0 3.0
855 855
0.670 1.70
95 2.41
1x8 1x8
330 8.38
2.681 6.81
6135 9130
570243
500 500
3.0 3.0
1221 1221
0.858 2.18
95 2.41
1x8 1x8
290 7.37
2.891 7.34
8028 11947
Cond. Size (AWG/Kcmil) DC Resistance @ 25C (ohms/1000') (ohms/km) AC Resistance @ 75C (ohms/1000') (ohms/km) Capacitive Reactance (Mohms x 1000ft) (Mohms x km) Inductive Reactance (ohms/1000') (ohms/km) Rated Strength (lbs) (kg) Max Pull Tension (lbs) (kg) Min. Bend Radius (in) (cm) In Air Ampacity @ 60C (amps) In Air Ampacity @ 75C (amps) In Air Ampacity @ 90C (amps) In Air Ampacity @ 105C (amps) Raceway Ampacity @ 75C (amps) Raceway Ampacity @ 90C (amps)
560537
8 8
0.679 1.01
0.818 1.22
0.052 0.08
3.9 9.91
48 48
57 57
65 65
558168
6 6
0.435 0.65
0.524 0.78
0.051 0.08
5.2 13.21
63 63
77 77
87 87
558169
4 4
0.274 0.41
0.33 0.49
0.048 0.07
5.8 14.73
84 84
101 101
114 114
558170
2 2
0.172 0.26
0.207 0.31
0.045 0.07
6.4 16.26
112 112
133 133
152 152
570098
1 1
0.137 0.20
0.164 0.24
0.046 0.07
7.2 18.29
131 131
156 156
177 177
558165
1/0 1/0
0.109 0.16
0.131 0.19
0.044 0.07
8.3 21.08
151 151
181 181
205 205
558166
2/0 2/0
0.087 0.13
0.104 0.15
0.043 0.06
8.5 21.59
174 174
208 208
237 237
560065
3/0 3/0
0.069 0.10
0.083 0.12
0.042 0.06
9.1 23.11
201 201
241 241
274 274
558167
4/0 4/0
0.055 0.08
0.067 0.10
0.041 0.06
9.8 24.89
232 232
277 277
316 316
570239
250 250
0.047 0.07
0.057 0.08
0.041 0.06
13.7 34.80
259 259
310 310
352 352
559281
350 350
0.033 0.05
0.042 0.06
0.04 0.06
16.0 40.64
318 318
381 381
433 433
570243
500 500
0.023 0.03
0.031 0.05
0.039 0.06
17.3 43.94
392 392
470 470
536 536

Standards & References

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
  • UL 1650 Standard for Portable Power Cable
  • RoHS-2 (European Directive 2011/65/EU)

Construction

  1. Conductor: Bare, soft drawn, annealed, flexible, rope-lay stranded copper per ASTM B3/B172
  2. Separator Tape: Non-conducting tape applied between the conductor and insulation to facilitate stripping
  3. Insulation: Ethylene Propylene Diene Monomer (EPDM). Color coded black, white, red
  4. Ground Check: One insulated, bare, soft drawn, annealed, rope stranded, flexible lay copper per ASTM B3/B172
  5. Ground Conductors: Two insulated, bare, soft drawn, annealed, rope stranded, flexible lay copper per ASTM B3/B172
  6. Fillers: Paper fillers applied as needed to round the cable core
  7. Reinforcement Binder: Reinforcing binder with twine applied over the core
  8. Jacket: Black, flame resistant, thermosetting Chlorinated Polyethylene (CPE)