14-2 SOL CU THHN BLACK/WHITE/GREEN AIA SIMpull MC (TM) MC 600V 250 FT

Southwire #: 13791401

Download Category Specifications
PDF Excel Table
Select Product Specifications
Construction
Conductor Color
Packaging

Application & Features

  • Suitable for use in branch and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
  • Type THHN/THWN rated 90ºC Dry
  • Suitable for use in concealed or exposed installations.
  • Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems
  • Saves time and labor with potential for less scrap on the jobsite
  • More compact than the standard MC design which reduces usage of packaging material and can save cost on shipping, transportation, and installation time
  • Re-engineered aluminum-interlocked-armor sheath prevents the armor from getting jammed during pulling, which reduces labor and boosts efficiency
  • Designed by ISO-Certified Cofer Technology Center

Specifications

Size (AWG or kcmil) (mm2) 14 AWG 14 AWG
No. of Conductors 2 2
No. of Strands 1 1
Nom. OD (mils) (mm) 425 10.80 mils mm
Insulation Thickness (mils) (mm) 15 0.38 mils mm
Nominal Total Weight (lbs/1000') (kgs/km) 86 128 lbs/1000' kgs/km
UPC # 032886308635 032886308635

Standards & References

Southwire SIMpull MC™ Cable meets or exceeds the following requirements:

  • UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
  • Federal Specification A-A59544 (formerly J-C-30B)
  • NFPA 70 (National Electrical Code), Article 330
  • Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems
  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 83 Thermoplastic Insulated Wires and Cables
  • UL 1569 Metal-Clad Cables
  • UL 1479 Standard for Safety Fire Tests of Penetration Firestops
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • REACH/RoHS-2 (Chemical Limit) Compliant
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
  • VW-1 (Vertical-Wire) Flame Test

Construction

Southwire SIMpull MC™ THHN/THWN cable is constructed with solid or 19 strand class C compressed copper conductors rated 90ºC dry and a green insulated ground. All phases are covered with a low profile aluminum interlocked armor.