Southwire’s shielded Machine Flex<sup>®</sup> tray control cables 600/1000 Volt conform to NFPA 79 and are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 75°C in wet locations and 90°C in dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. For uses in Class I, II, Division 2 hazardous locations per NEC® Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC® 336.10. Southwire’s shielded flexible machine tray cable is ideal for use in for use in CNC machines, grinding, cutting, metal forming, buffing, bottling equipment, conveyors, processing & packaging equipment, assembly lines, control panels, food and bever- age, oil sands, plant expansion, wind energy and data centers. Multiple approvals for multiple applications. Cable is rated for -40°C cold impact. Two conductor cables contain no green/yellow ground.
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Color | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Min. Bend Radius (in) (cm) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
677081 |
18
18
|
2.0
2.0
|
16
16
|
0.044
0.11
|
|
15
0.38
|
|
|
|
45
1.14
|
0.293
0.74
|
24
36
|
|
52
77
|
7.148
10.64
|
8.613
12.82
|
3.5
8.89
|
-
-
|
14
14
|
588460 |
18
18
|
3.0
3.0
|
16
16
|
0.044
0.11
|
|
15
0.38
|
|
|
|
45
1.14
|
0.320
0.81
|
30
45
|
|
63
94
|
7.148
10.64
|
8.613
12.82
|
3.8
9.65
|
-
-
|
14
14
|
588461 |
18
18
|
4.0
4.0
|
16
16
|
0.044
0.11
|
|
15
0.38
|
|
|
|
45
1.14
|
0.326
0.83
|
36
54
|
|
70
104
|
7.148
10.64
|
8.613
12.82
|
3.9
9.91
|
-
-
|
11
11
|
588462 |
18
18
|
5.0
5.0
|
16
16
|
0.044
0.11
|
|
15
0.38
|
|
|
|
45
1.14
|
0.353
0.90
|
43
64
|
|
82
122
|
7.148
10.64
|
8.613
12.82
|
4.2
10.67
|
-
-
|
11
11
|
588463 |
18
18
|
7.0
7.0
|
16
16
|
0.044
0.11
|
|
15
0.38
|
|
|
|
45
1.14
|
0.378
0.96
|
55
82
|
|
100
149
|
7.148
10.64
|
8.613
12.82
|
4.5
11.43
|
-
-
|
9
9
|
630837 |
18
18
|
9.0
9.0
|
16
16
|
0.044
0.11
|
|
15
0.38
|
|
|
|
45
1.14
|
0.442
1.12
|
68
101
|
|
129
192
|
7.148
10.64
|
8.613
12.82
|
5.3
13.46
|
-
-
|
9
9
|
588464 |
18
18
|
12.0
12.0
|
16
16
|
0.044
0.11
|
|
15
0.38
|
|
|
|
45
1.14
|
0.478
1.21
|
86
128
|
|
155
231
|
7.148
10.64
|
8.613
12.82
|
5.7
14.48
|
-
-
|
7
7
|
598625 |
18
18
|
18.0
18.0
|
16
16
|
0.044
0.11
|
|
15
0.38
|
|
|
|
60
1.52
|
0.576
1.46
|
119
177
|
|
222
330
|
7.148
10.64
|
8.613
12.82
|
6.9
17.53
|
-
-
|
7
7
|
598626 |
18
18
|
25.0
25.0
|
16
16
|
0.044
0.11
|
|
15
0.38
|
|
|
|
60
1.52
|
0.658
1.67
|
161
240
|
|
289
430
|
7.148
10.64
|
8.613
12.82
|
7.8
19.81
|
-
-
|
6
6
|
677082 |
16
16
|
2.0
2.0
|
26
26
|
0.059
0.15
|
|
15
0.38
|
|
|
|
45
1.14
|
0.321
0.82
|
34
51
|
|
66
98
|
4.487
6.68
|
5.406
8.05
|
3.8
9.65
|
-
-
|
18
18
|
588465 |
16
16
|
3.0
3.0
|
26
26
|
0.059
0.15
|
|
15
0.38
|
|
|
|
45
1.14
|
0.331
0.84
|
43
64
|
|
78
116
|
4.487
6.68
|
5.406
8.05
|
3.9
9.91
|
-
-
|
18
18
|
588466 |
16
16
|
4.0
4.0
|
26
26
|
0.059
0.15
|
|
15
0.38
|
|
|
|
45
1.14
|
0.360
0.91
|
53
79
|
|
93
138
|
4.487
6.68
|
5.406
8.05
|
4.3
10.92
|
-
-
|
14
14
|
588467 |
16
16
|
5.0
5.0
|
26
26
|
0.059
0.15
|
|
15
0.38
|
|
|
|
45
1.14
|
0.391
0.99
|
63
94
|
|
110
164
|
4.487
6.68
|
5.406
8.05
|
4.6
11.68
|
-
-
|
14
14
|
588468 |
16
16
|
7.0
7.0
|
26
26
|
0.059
0.15
|
|
15
0.38
|
|
|
|
45
1.14
|
0.427
1.08
|
80
119
|
|
135
201
|
4.487
6.68
|
5.406
8.05
|
5.1
12.95
|
-
-
|
12
12
|
630836 |
16
16
|
9.0
9.0
|
26
26
|
0.059
0.15
|
|
15
0.38
|
|
|
|
45
1.14
|
0.491
1.25
|
100
149
|
|
171
254
|
4.487
6.68
|
5.406
8.05
|
5.8
14.73
|
-
-
|
12
12
|
588469 |
16
16
|
12.0
12.0
|
26
26
|
0.059
0.15
|
|
15
0.38
|
|
|
|
60
1.52
|
0.562
1.43
|
128
190
|
|
220
327
|
4.487
6.68
|
5.406
8.05
|
6.7
17.02
|
-
-
|
9
9
|
598627 |
16
16
|
18.0
18.0
|
26
26
|
0.059
0.15
|
|
15
0.38
|
|
|
|
60
1.52
|
0.646
1.64
|
185
275
|
|
303
451
|
4.487
6.68
|
5.406
8.05
|
7.7
19.56
|
-
-
|
9
9
|
598628 |
16
16
|
25.0
25.0
|
26
26
|
0.059
0.15
|
|
15
0.38
|
|
|
|
60
1.52
|
0.746
1.89
|
248
369
|
|
398
592
|
4.487
6.68
|
5.406
8.05
|
8.9
22.61
|
-
-
|
8
8
|
677083 |
14
14
|
2.0
2.0
|
41
41
|
0.073
0.19
|
|
15
0.38
|
|
|
|
45
1.14
|
0.349
0.89
|
48
71
|
|
84
125
|
2.814
4.19
|
3.391
5.05
|
4.1
10.41
|
20
20
|
25
25
|
588470 |
14
14
|
3.0
3.0
|
41
41
|
0.073
0.19
|
|
15
0.38
|
|
|
|
45
1.14
|
0.363
0.92
|
62
92
|
|
102
152
|
2.814
4.19
|
3.391
5.05
|
4.3
10.92
|
20
20
|
25
25
|
588471 |
14
14
|
4.0
4.0
|
41
41
|
0.073
0.19
|
|
15
0.38
|
|
|
|
45
1.14
|
0.402
1.02
|
76
113
|
|
125
186
|
2.814
4.19
|
3.391
5.05
|
4.8
12.19
|
16
16
|
20
20
|
588472 |
14
14
|
5.0
5.0
|
41
41
|
0.073
0.19
|
|
15
0.38
|
|
|
|
45
1.14
|
0.431
1.09
|
91
135
|
|
144
214
|
2.814
4.19
|
3.391
5.05
|
5.1
12.95
|
16
16
|
20
20
|
588473 |
14
14
|
7.0
7.0
|
41
41
|
0.073
0.19
|
|
15
0.38
|
|
|
|
45
1.14
|
0.466
1.18
|
119
177
|
|
178
265
|
2.814
4.19
|
3.391
5.05
|
5.5
13.97
|
14
14
|
17
17
|
598629 |
14
14
|
12.0
12.0
|
41
41
|
0.073
0.19
|
|
15
0.38
|
|
|
|
60
1.52
|
0.623
1.58
|
192
286
|
|
297
442
|
2.814
4.19
|
3.391
5.05
|
7.4
18.80
|
10
10
|
12
12
|
598630 |
14
14
|
18.0
18.0
|
41
41
|
0.073
0.19
|
|
15
0.38
|
|
|
|
60
1.52
|
0.720
1.83
|
277
412
|
|
412
613
|
2.814
4.19
|
3.391
5.05
|
8.6
21.84
|
10
10
|
12
12
|
598631 |
14
14
|
25.0
25.0
|
41
41
|
0.073
0.19
|
|
15
0.38
|
|
|
|
80
2.03
|
0.875
2.22
|
384
571
|
|
582
866
|
2.814
4.19
|
3.391
5.05
|
10.5
26.67
|
9
9
|
11
11
|
677084 |
12
12
|
2.0
2.0
|
65
65
|
0.094
0.24
|
|
15
0.38
|
|
|
|
45
1.14
|
0.387
0.98
|
70
104
|
|
112
167
|
1.774
2.64
|
2.137
3.18
|
4.6
11.68
|
25
25
|
30
30
|
677194 |
12
12
|
3.0
3.0
|
65
65
|
0.094
0.24
|
|
15
0.38
|
|
|
|
45
1.14
|
0.416
1.06
|
91
135
|
|
142
211
|
1.774
2.64
|
2.137
3.18
|
4.9
12.45
|
25
25
|
30
30
|
588474 |
12
12
|
4.0
4.0
|
65
65
|
0.094
0.24
|
|
15
0.38
|
|
|
|
45
1.14
|
0.450
1.14
|
114
170
|
|
172
256
|
1.774
2.64
|
2.137
3.18
|
5.4
13.72
|
20
20
|
24
24
|
588476 |
12
12
|
5.0
5.0
|
65
65
|
0.094
0.24
|
|
15
0.38
|
|
|
|
45
1.14
|
0.489
1.24
|
138
205
|
|
207
308
|
1.774
2.64
|
2.137
3.18
|
5.8
14.73
|
20
20
|
24
24
|
588477 |
12
12
|
7.0
7.0
|
65
65
|
0.094
0.24
|
|
15
0.38
|
|
|
|
60
1.52
|
0.555
1.41
|
181
269
|
|
268
399
|
1.774
2.64
|
2.137
3.18
|
6.6
16.76
|
17
17
|
21
21
|
677085 |
10
10
|
2.0
2.0
|
105
105
|
0.117
0.30
|
|
20
0.51
|
|
|
|
60
1.52
|
0.455
1.16
|
102
152
|
|
159
237
|
1.111
1.65
|
1.339
1.99
|
5.4
13.72
|
35
35
|
40
40
|
677196 |
10
10
|
3.0
3.0
|
105
105
|
0.117
0.30
|
|
20
0.51
|
|
|
|
60
1.52
|
0.544
1.38
|
136
202
|
|
218
324
|
1.111
1.65
|
1.339
1.99
|
6.5
16.51
|
35
35
|
40
40
|
588478 |
10
10
|
4.0
4.0
|
105
105
|
0.117
0.30
|
|
20
0.51
|
|
|
|
60
1.52
|
0.574
1.46
|
177
263
|
|
268
399
|
1.111
1.65
|
1.339
1.99
|
6.8
17.27
|
28
28
|
32
32
|
588479 |
10
10
|
5.0
5.0
|
105
105
|
0.117
0.30
|
|
20
0.51
|
|
|
|
60
1.52
|
0.608
1.54
|
212
315
|
|
316
470
|
1.111
1.65
|
1.339
1.99
|
7.2
18.29
|
28
28
|
32
32
|
588480 |
10
10
|
7.0
7.0
|
105
105
|
0.117
0.30
|
|
20
0.51
|
|
|
|
60
1.52
|
0.658
1.67
|
280
417
|
|
394
586
|
1.111
1.65
|
1.339
1.99
|
7.8
19.81
|
24
24
|
28
28
|
643354 |
8
8
|
4.0
4.0
|
168
168
|
0.153
0.39
|
|
30
0.76
|
|
|
|
60
1.52
|
0.742
1.88
|
292
435
|
|
438
652
|
0.715
1.06
|
0.861
1.28
|
8.9
22.61
|
40
40
|
44
44
|
643356 |
6
6
|
4.0
4.0
|
259
259
|
0.198
0.50
|
|
30
0.76
|
|
|
|
60
1.52
|
0.885
2.25
|
463
689
|
|
668
994
|
0.45
0.67
|
0.541
0.81
|
10.6
26.92
|
52
52
|
60
60
|
643358 |
4
4
|
4.0
4.0
|
420
420
|
0.235
0.60
|
|
40
1.02
|
|
|
|
80
2.03
|
1.057
2.68
|
674
1003
|
|
997
1484
|
0.282
0.42
|
0.34
0.51
|
12.6
32.00
|
68
68
|
76
76
|
643360 |
2
2
|
4.0
4.0
|
651
651
|
0.302
0.77
|
|
40
1.02
|
|
|
|
80
2.03
|
1.237
3.14
|
1060
1577
|
|
1433
2133
|
0.179
0.27
|
0.216
0.32
|
14.8
37.59
|
92
92
|
104
104
|