Southwire’s 600 Volt Type MC power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Silicone Free.
Cond. Size | Cond. Strands | Diameter Over Conductor (in) (cm) | Inner Layer Thickness (mils) (mm) | Diameter Over Armor (in) (cm) | Outer Layer Thickness (mils) (mm) | Approx. OD (in) (cm) | Approx. Weight (lbs/1000') (kgs/km) | Max Pull Tension (lbs) (kg) | Min. Bend Radius (in) (cm) | |
More Options |
8 AWG
8 AWG
|
7
7
|
0.141
0.36
|
45
1.14
|
0.721
1.83
|
50
1.27
|
0.821
2.09
|
404
601
|
396
179.62
|
5.7
14.48
|
More Options |
6 AWG
6 AWG
|
7
7
|
0.177
0.45
|
45
1.14
|
0.788
2.00
|
50
1.27
|
0.888
2.26
|
545
811
|
629
285.31
|
6.2
15.75
|
More Options |
4 AWG
4 AWG
|
7
7
|
0.225
0.57
|
45
1.14
|
0.898
2.28
|
50
1.27
|
0.998
2.53
|
713
1061
|
1001
454.05
|
7.0
17.78
|
More Options |
2 AWG
2 AWG
|
7
7
|
0.282
0.72
|
45
1.14
|
1.019
2.59
|
50
1.27
|
1.119
2.84
|
1046
1557
|
1592
722.12
|
7.8
19.81
|
More Options |
1 AWG
1 AWG
|
19
19
|
0.322
0.82
|
55
1.40
|
1.151
2.92
|
50
1.27
|
1.251
3.18
|
1264
1881
|
2008
910.81
|
8.8
22.35
|
More Options |
1/0 AWG
1/0 AWG
|
19
19
|
0.361
0.92
|
55
1.40
|
1.233
3.13
|
50
1.27
|
1.333
3.39
|
1499
2231
|
2534
1149.40
|
9.3
23.62
|
More Options |
2/0 AWG
2/0 AWG
|
19
19
|
0.405
1.03
|
55
1.40
|
1.328
3.37
|
50
1.27
|
1.428
3.63
|
1816
2703
|
3194
1448.77
|
10.0
25.40
|
More Options |
3/0 AWG
3/0 AWG
|
19
19
|
0.456
1.16
|
55
1.40
|
1.436
3.65
|
50
1.27
|
1.536
3.90
|
2256
3357
|
4027
1826.61
|
10.8
27.43
|
More Options |
4/0 AWG
4/0 AWG
|
19
19
|
0.512
1.30
|
55
1.40
|
1.631
4.14
|
60
1.52
|
1.751
4.45
|
2786
4146
|
5078
2303.34
|
12.3
31.24
|
More Options |
250 KCMIL
250 KCMIL
|
37
37
|
0.558
1.42
|
65
1.65
|
1.769
4.49
|
60
1.52
|
1.889
4.80
|
3379
5029
|
6000
2721.55
|
13.2
33.53
|
More Options |
350 KCMIL
350 KCMIL
|
37
37
|
0.661
1.68
|
65
1.65
|
1.983
5.04
|
60
1.52
|
2.103
5.34
|
4551
6773
|
8400
3810.17
|
14.7
37.34
|
More Options |
500 KCMIL
500 KCMIL
|
37
37
|
0.789
2.00
|
65
1.65
|
2.253
5.72
|
75
1.91
|
2.403
6.10
|
6180
9197
|
12000
5443.10
|
16.8
42.67
|
More Options |
600 KCMIL
600 KCMIL
|
61
61
|
0.865
2.20
|
80
2.03
|
2.507
6.37
|
75
1.91
|
2.657
6.75
|
7604
11316
|
14400
6531.72
|
18.6
47.24
|
More Options |
750 KCMIL
750 KCMIL
|
61
61
|
0.968
2.46
|
80
2.03
|
2.758
7.01
|
75
1.91
|
2.908
7.39
|
9227
13731
|
18000
8164.66
|
20.4
51.82
|
Cond. Size | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Capacitive Reactance (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | |
More Options |
8 AWG
8 AWG
|
0.653
0.97
|
0.786
1.17
|
0.033
0.05
|
0.052
0.08
|
More Options |
6 AWG
6 AWG
|
0.411
0.61
|
0.495
0.74
|
0.027
0.04
|
0.051
0.08
|
More Options |
4 AWG
4 AWG
|
0.258
0.38
|
0.310
0.46
|
0.022
0.03
|
0.048
0.07
|
More Options |
2 AWG
2 AWG
|
0.162
0.24
|
0.195
0.29
|
0.018
0.03
|
0.045
0.07
|
More Options |
1 AWG
1 AWG
|
0.128
0.19
|
0.154
0.23
|
0.019
0.03
|
0.046
0.07
|
More Options |
1/0 AWG
1/0 AWG
|
0.102
0.15
|
0.122
0.18
|
0.017
0.03
|
0.044
0.07
|
More Options |
2/0 AWG
2/0 AWG
|
0.081
0.12
|
0.097
0.14
|
0.016
0.02
|
0.043
0.06
|
More Options |
3/0 AWG
3/0 AWG
|
0.064
0.10
|
0.078
0.12
|
0.014
0.02
|
0.042
0.06
|
More Options |
4/0 AWG
4/0 AWG
|
0.051
0.08
|
0.062
0.09
|
0.013
0.02
|
0.041
0.06
|
More Options |
250 KCMIL
250 KCMIL
|
0.043
0.06
|
0.053
0.08
|
0.014
0.02
|
0.041
0.06
|
More Options |
350 KCMIL
350 KCMIL
|
0.031
0.05
|
0.039
0.06
|
0.012
0.02
|
0.040
0.06
|
More Options |
500 KCMIL
500 KCMIL
|
0.022
0.03
|
0.029
0.04
|
0.010
0.01
|
0.039
0.06
|
More Options |
600 KCMIL
600 KCMIL
|
0.018
0.03
|
0.025
0.04
|
0.011
0.02
|
0.039
0.06
|
More Options |
750 KCMIL
750 KCMIL
|
0.014
0.02
|
0.022
0.03
|
0.010
0.01
|
0.038
0.06
|
* Ampacities based upon 2023 NEC Table 310.16. See NEC sections 310.15 and 110.14(C) for additional requirements.