SPEC25040 CSA TECK 90 600V PVC CONTROL CABLE

600V Multi Conductor, 14-10 AWG Copper, FT4 - Flame Retardancy Rating, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40°C - 90°C, Rated HL, AG14

Download Category Specifications
PDF Excel Table

Application

For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Sunlight Resistant. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. <br> <ul> <li>-40°C - CSA Cold Bend and Impact Temperature</li> <li> -40°C - Min. Installation Temperature</li> <li> 90°C - Max. Continuous Operating Temperature</li> </ul>

Specifications

Select a set of products below for more information:
Cond. Size (AWG/Kcmil) Cond. Strands Diameter Over Conductor (in) (cm) Diameter Over Insulation (in) (cm) Insulation Thickness (mils) (mm) Diameter Over Shield (in) (cm) Ground (No. x AWG) Inner Jacket Thickness (mils) (mm) Diameter Over Armor (in) (cm) Drain Wire Jacket Thickness (mils) (mm) Approx. OD (in) (cm) Approx. Weight (lbs/1000') (kgs/km) Max Pull Tension (lbs) (kg) Min. Bend Radius (in) (cm) Conduit Size (in) (cm)
562239
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
50 1.27
0.570 1.45
45 1.14
0.660 1.68
196 292
65 29.48
4.6 11.68
561778
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
85 2.16
1.283 3.26
45 1.14
1.373 3.49
903 1344
822 372.85
9.6 24.38
561781
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
50 1.27
0.625 1.59
45 1.14
0.715 1.82
247 368
131 59.42
5.0 12.70
561788
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
50 1.27
0.663 1.68
45 1.14
0.753 1.91
276 411
164 74.39
5.2 13.21
562248
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
50 1.27
0.702 1.78
45 1.14
0.792 2.01
305 454
197 89.36
5.5 13.97
561789
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
65 1.65
0.702 1.78
45 1.14
0.792 2.01
324 482
230 104.33
5.5 13.97
562254
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
65 1.65
0.774 1.97
45 1.14
0.864 2.19
377 561
263 119.29
6.0 15.24
562258
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
65 1.65
0.866 2.20
45 1.14
0.956 2.43
442 658
328 148.78
6.6 16.76
561790
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
65 1.65
0.887 2.25
45 1.14
0.977 2.48
483 719
394 178.72
6.8 17.27
562263
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
65 1.65
0.954 2.42
45 1.14
1.044 2.65
556 827
493 223.62
7.3 18.54
561791
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
85 2.16
1.109 2.82
45 1.14
1.199 3.05
697 1037
624 283.04
8.3 21.08
562269
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
85 2.16
1.136 2.89
45 1.14
1.226 3.11
724 1077
657 298.01
8.5 21.59
561778
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
85 2.16
1.283 3.26
45 1.14
1.373 3.49
903 1344
822 372.85
9.6 24.38
562275
14 14
7 7
0.070 0.18
30 0.76
1x14 1x14
85 2.16
1.338 3.40
45 1.14
1.428 3.63
1012 1506
986 447.24
9.9 25.15
561792
12 12
7 7
0.088 0.22
30 0.76
1x14 1x14
50 1.27
0.605 1.54
45 1.14
0.695 1.77
222 330
104 47.17
4.8 12.19
561792
12 12
7 7
0.088 0.22
30 0.76
1x14 1x14
50 1.27
0.605 1.54
45 1.14
0.695 1.77
222 330
104 47.17
4.8 12.19
561793
12 12
7 7
0.088 0.22
30 0.76
1x14 1x14
50 1.27
0.629 1.60
45 1.14
0.719 1.83
256 381
156 70.76
5.0 12.70
561794
12 12
7 7
0.088 0.22
30 0.76
1x14 1x14
50 1.27
0.667 1.69
45 1.14
0.757 1.92
293 436
208 94.35
5.2 13.21
589296
12 12
7 7
0.088 0.22
30 0.76
1x14 1x14
65 1.65
0.710 1.80
45 1.14
0.800 2.03
332 494
261 118.39
5.6 14.22
567116
12 12
7 7
0.088 0.22
30 0.76
1x14 1x14
65 1.65
0.786 2.00
45 1.14
0.876 2.23
395 588
313 141.97
6.1 15.49
584397
12 12
7 7
0.088 0.22
30 0.76
1x14 1x14
65 1.65
0.786 2.00
45 1.14
0.876 2.23
422 628
365 165.56
6.1 15.49
568599
12 12
7 7
0.088 0.22
30 0.76
1x14 1x14
65 1.65
0.833 2.12
45 1.14
0.923 2.34
463 689
417 189.15
6.4 16.26
563506
12 12
7 7
0.088 0.22
30 0.76
1x14 1x14
65 1.65
0.936 2.38
45 1.14
1.026 2.61
549 817
522 236.78
7.1 18.03
563511
12 12
7 7
0.088 0.22
30 0.76
1x14 1x14
85 2.16
1.195 3.04
45 1.14
1.285 3.26
816 1214
783 355.16
8.9 22.61
563515
12 12
7 7
0.088 0.22
30 0.76
1x14 1x14
85 2.16
1.285 3.26
45 1.14
1.375 3.49
981 1460
1044 473.55
9.6 24.38
589299
12 12
7 7
0.088 0.22
30 0.76
1x14 1x14
85 2.16
1.389 3.53
45 1.14
1.479 3.76
1156 1720
1306 592.39
10.3 26.16
587679
12 12
7 7
0.088 0.22
30 0.76
1x14 1x14
85 2.16
1.425 3.62
45 1.14
1.515 3.85
1295 1927
1567 710.78
10.6 26.92
562290
10 10
7 7
0.113 0.29
30 0.76
1x12 1x12
50 1.27
0.653 1.66
45 1.14
0.743 1.89
270 402
166 75.30
5.2 13.21
561797
10 10
7 7
0.113 0.29
30 0.76
1x12 1x12
50 1.27
0.680 1.73
45 1.14
0.770 1.96
319 475
249 112.94
5.3 13.46
561798
10 10
7 7
0.113 0.29
30 0.76
1x12 1x12
65 1.65
0.725 1.84
45 1.14
0.815 2.07
371 552
332 150.59
5.7 14.48
567109
10 10
7 7
0.113 0.29
30 0.76
1x12 1x12
65 1.65
0.858 2.18
45 1.14
0.948 2.41
505 752
498 225.89
6.6 16.76
584443
10 10
7 7
0.113 0.29
30 0.76
1x12 1x12
65 1.65
0.918 2.33
45 1.14
1.008 2.56
604 899
664 301.19
7.0 17.78
567096
10 10
7 7
0.113 0.29
30 0.76
1x12 1x12
85 2.16
1.142 2.90
45 1.14
1.232 3.13
777 1156
830 376.48
8.6 21.84
589343
10 10
7 7
0.113 0.29
30 0.76
1x12 1x12
85 2.16
1.211 3.08
45 1.14
1.301 3.30
911 1356
996 451.78
9.1 23.11
567102
10 10
7 7
0.113 0.29
30 0.76
1x12 1x12
85 2.16
1.307 3.32
45 1.14
1.397 3.55
1067 1588
1245 564.72
9.7 24.64
Cond. Size (AWG/Kcmil) DC Resistance @ 25C (ohms/1000') (ohms/km) AC Resistance @ 75C (ohms/1000') (ohms/km) Capacitive Reactance (Mohms x 1000ft) (Mohms x km) Inductive Reactance (ohms/1000') (ohms/km) Zero Sequence Impedance (ohms/1000') (ohms/1000') Positive Sequence Impedance (ohms/1000') (ohms/1000') Shield Short Circuit Current 6 Cycles (amps) Direct Buried Ampacity @ 90C (amps) Direct Buried Ampacity @ 105C (amps) In Duct Ampacity @ 90C (amps) In Duct Ampacity @ 105C (amps) In Air Ampacity @ 90C (amps) In Air Ampacity @ 105C (amps)
562239
14 14
2.631 3.92
3.17 4.72
0.058 0.09
561778
14 14
2.631 3.92
3.17 4.72
0.058 0.09
561781
14 14
2.631 3.92
3.17 4.72
0.058 0.09
561788
14 14
2.631 3.92
3.17 4.72
0.058 0.09
562248
14 14
2.631 3.92
3.17 4.72
0.058 0.09
561789
14 14
2.631 3.92
3.17 4.72
0.058 0.09
562254
14 14
2.631 3.92
3.17 4.72
0.058 0.09
562258
14 14
2.631 3.92
3.17 4.72
0.058 0.09
561790
14 14
2.631 3.92
3.17 4.72
0.058 0.09
562263
14 14
2.631 3.92
3.17 4.72
0.058 0.09
561791
14 14
2.631 3.92
3.17 4.72
0.058 0.09
562269
14 14
2.631 3.92
3.17 4.72
0.058 0.09
561778
14 14
2.631 3.92
3.17 4.72
0.058 0.09
562275
14 14
2.631 3.92
3.17 4.72
0.058 0.09
561792
12 12
1.662 2.47
2.002 2.98
0.054 0.08
561792
12 12
1.662 2.47
2.002 2.98
0.054 0.08
561793
12 12
1.662 2.47
2.002 2.98
0.054 0.08
561794
12 12
1.662 2.47
2.002 2.98
0.054 0.08
589296
12 12
1.662 2.47
2.002 2.98
0.054 0.08
567116
12 12
1.662 2.47
2.002 2.98
0.054 0.08
584397
12 12
1.662 2.47
2.002 2.98
0.054 0.08
568599
12 12
1.662 2.47
2.002 2.98
0.054 0.08
563506
12 12
1.662 2.47
2.002 2.98
0.054 0.08
563511
12 12
1.662 2.47
2.002 2.98
0.054 0.08
563515
12 12
1.662 2.47
2.002 2.98
0.054 0.08
589299
12 12
1.662 2.47
2.002 2.98
0.054 0.08
587679
12 12
1.662 2.47
2.002 2.98
0.054 0.08
562290
10 10
1.04 1.55
1.253 1.86
0.05 0.07
561797
10 10
1.04 1.55
1.253 1.86
0.05 0.07
561798
10 10
1.04 1.55
1.253 1.86
0.05 0.07
567109
10 10
1.04 1.55
1.253 1.86
0.05 0.07
584443
10 10
1.04 1.55
1.253 1.86
0.05 0.07
567096
10 10
1.04 1.55
1.253 1.86
0.05 0.07
589343
10 10
1.04 1.55
1.253 1.86
0.05 0.07
567102
10 10
1.04 1.55
1.253 1.86
0.05 0.07

Standards & References

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • CSA C22.2 No. 174 Cables in Hazardous Locations
  • CSA C22.2 No. 131 Type TECK 90 Cable
  • CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
  • CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
  • CSA HL - for Hazardous Locations rating
  • CSA SUN RES - for Sunlight Resistant rating
  • CSA AG14 - Acid Gas Compliance
  • IEEE 383 Flame Test (70,000 btu)
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test

Construction

  1. Conductor: Class B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.
  2. Insulation: Cross-Linked Polyethylene (XLPE), Colour Code: 2/C black, white; 3/C red, black, blue; 4/C red, black, blue, white; For 5/C cables or more, the insulation is black and numbered
  3. Grounding Conductors: Uninsulated Class B stranded grounding conductor
  4. Inner Jacket: Black Polyvinyl Chloride (PVC)
  5. Armor: Aluminum Interlocked Armour (AIA)
  6. Overall Jacket: Black PVC (optional colours available)

Resources

There are no downloadable resources for this product.