Southwire’s 5KV ARMOR-X<SUP>®</SUP> MC HL are armored cables for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, 250°C for short circuit conditions, and -50°C for cold bend. For uses in Class I, II, and III, Division 1 and 2 hazardous locations per NEC Article 501, 502, and 503. Suitable for VFD application.
Cond. Size (AWG/Kcmil) | Cond. Strands | Diameter Over Conductor (in) (cm) | Diameter Over Insulation (in) (cm) | Insulation Thickness (mils) (mm) | Diameter Over Shield (in) (cm) | Ground (No. x AWG) | Inner Jacket Thickness (mils) (mm) | Diameter Over Armor (in) (cm) | Drain Wire | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Approx. Weight (lbs/1000') (kgs/km) | Max Pull Tension (lbs) (kg) | Min. Bend Radius (in) (cm) | Conduit Size (in) (cm) | |
890636 |
2
2
|
7
7
|
0.282
0.72
|
0.545
1.38
|
115
2.92
|
0.605
1.54
|
3x10
3x10
|
|
1.670
4.24
|
|
70
1.78
|
1.810
4.60
|
1903
2832
|
1592
722.12
|
12.6
32.00
|
|
890637 |
1
1
|
19
19
|
0.322
0.82
|
0.590
1.50
|
115
2.92
|
0.650
1.65
|
3x8
3x8
|
|
1.845
4.69
|
|
70
1.78
|
1.985
5.04
|
2208
3286
|
2008
910.81
|
13.8
35.05
|
|
890639 |
2/0
2/0
|
19
19
|
0.405
1.03
|
0.674
1.71
|
115
2.92
|
0.734
1.86
|
3x8
3x8
|
|
2.040
5.18
|
|
60
1.52
|
2.160
5.49
|
2799
4165
|
3194
1448.77
|
15.1
38.35
|
|
890640 |
4/0
4/0
|
19
19
|
0.512
1.30
|
0.766
1.95
|
115
2.92
|
0.826
2.10
|
3x6
3x6
|
|
2.290
5.82
|
|
75
1.91
|
2.440
6.20
|
3986
5932
|
5078
2303.34
|
17.0
43.18
|
|
890641 |
250
250
|
37
37
|
0.558
1.42
|
0.818
2.08
|
115
2.92
|
0.878
2.23
|
3x6
3x6
|
|
2.290
5.82
|
|
75
1.91
|
2.440
6.20
|
4692
6982
|
6000
2721.55
|
17.0
43.18
|
|
890642 |
350
350
|
37
37
|
0.661
1.68
|
0.917
2.33
|
115
2.92
|
0.977
2.48
|
3x6
3x6
|
|
2.550
6.48
|
|
75
1.91
|
2.700
6.86
|
5901
8782
|
8400
3810.17
|
18.9
48.01
|
|
890643 |
500
500
|
37
37
|
0.789
2.00
|
1.042
2.65
|
115
2.92
|
1.102
2.80
|
3x4
3x4
|
|
2.880
7.32
|
|
75
1.91
|
3.030
7.70
|
7533
11210
|
12000
5443.10
|
21.2
53.85
|
|
890644 |
750
750
|
61
61
|
0.968
2.46
|
1.254
3.19
|
115
2.92
|
1.314
3.34
|
3x4
3x4
|
|
3.540
8.99
|
|
85
2.16
|
3.710
9.42
|
10969
16324
|
18000
8164.66
|
25.9
65.79
|
|
Cond. Size (AWG/Kcmil) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Capacitive Reactance (Mohms x 1000ft) (Mohms x km) | Inductive Reactance (ohms/1000') (ohms/km) | Zero Sequence Impedance (ohms/1000') (ohms/1000') | Positive Sequence Impedance (ohms/1000') (ohms/1000') | Shield Short Circuit Current 6 Cycles (amps) | Direct Buried Ampacity @ 90C (amps) | Direct Buried Ampacity @ 105C (amps) | In Duct Ampacity @ 90C (amps) | In Duct Ampacity @ 105C (amps) | In Air Ampacity @ 90C (amps) | In Air Ampacity @ 105C (amps) | |
890636 |
2
2
|
0.162
0.24
|
0.204
0.30
|
0.034
0.05
|
0.04
0.06
|
0.574 + j0.516
0.574 + j0.516
|
0.204 + j0.041
0.204 + j0.041
|
1920
1920
|
|
|
135
135
|
145
145
|
140
140
|
154
154
|
890637 |
1
1
|
0.128
0.19
|
0.162
0.24
|
0.031
0.05
|
0.039
0.06
|
0.535 + j0.492
0.535 + j0.492
|
0.162 + j0.039
0.162 + j0.039
|
2044
2044
|
|
|
155
155
|
165
165
|
160
160
|
180
180
|
890639 |
2/0
2/0
|
0.081
0.12
|
0.102
0.15
|
0.026
0.04
|
0.036
0.05
|
0.477 + j0.449
0.477 + j0.449
|
0.102 + j0.036
0.102 + j0.036
|
2302
2302
|
|
|
200
200
|
220
220
|
215
215
|
240
240
|
890640 |
4/0
4/0
|
0.051
0.08
|
0.065
0.10
|
0.021
0.03
|
0.034
0.05
|
0.439 + j0.399
0.439 + j0.399
|
0.065 + j0.034
0.065 + j0.034
|
2633
2633
|
|
|
265
265
|
280
280
|
285
285
|
320
320
|
890641 |
250
250
|
0.043
0.06
|
0.056
0.08
|
0.02
0.03
|
0.033
0.05
|
0.428 + j0.376
0.428 + j0.376
|
0.056 + j0.033
0.056 + j0.033
|
2800
2800
|
|
|
290
290
|
315
315
|
320
320
|
355
355
|
890642 |
350
350
|
0.031
0.05
|
0.041
0.06
|
0.018
0.03
|
0.032
0.05
|
0.406 + j0.338
0.406 + j0.338
|
0.041 + j0.032
0.041 + j0.032
|
3120
3120
|
|
|
355
355
|
380
380
|
395
395
|
440
440
|
890643 |
500
500
|
0.022
0.03
|
0.03
0.04
|
0.015
0.02
|
0.03
0.04
|
0.385 + j0.297
0.385 + j0.297
|
0.03 + j0.03
0.03 + j0.03
|
3516
3516
|
|
|
430
430
|
460
460
|
485
485
|
545
545
|
890644 |
750
750
|
0.014
0.02
|
0.023
0.03
|
0.013
0.02
|
0.029
0.04
|
0.36 + j0.248
0.36 + j0.248
|
0.023 + j0.029
0.023 + j0.029
|
4102
4102
|
|
|
530
530
|
570
570
|
615
615
|
685
685
|