600V ROYAL® SOOW Cord with Black Jacket 90°C

600V ROYAL® SOOW Cord with Black Jacket 90°C

600 Volt 90°C Flexible Cord. Heat, Moisture and Oil Resistant EPDM Rubber Insulation, Heat, Moisture and Oil Resistant Flexible CPE Jacket.
Download Category Specifications:
PDF Excel Table

Application

Southwire Type SOOW Flexible Cords UL/ CSA listed are permitted for use as specified by Article 400 and related articles of the 2014 National Electrical Code. The cable is rated -40°C to 90°C, water, oil, and weather resistant. Southwire Type SOOW Flexible Cords are designed for extra hard usage on industrial equipment, heavy tools, battery chargers, portable lights, welding leads, marine dockside power, power extensions and mining applications.

Specifications

measurement
imperial metric
Select a set of products below for more information:
Conductor
Size (AWG or kcmil) No. of Conductors No. of Strands Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km) Allowable Ampacity Nom. DC Resistance (Conductor) Conductor Colors
558235 18 AWG 18 AWG 5 5 16 16 465 11.81 134 200 5.5 5.5 6.59 6.59 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
558100 16 AWG 16 AWG 3 3 26 26 395 10.03 95 141 13 13 4.05 4.05 BLACK/WHITE/GREEN BLACK/WHITE/GREEN
558101 16 AWG 16 AWG 4 4 26 26 420 10.67 107 159 10 10 4.05 4.05 BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
558231 16 AWG 16 AWG 5 5 26 26 515 13.08 157 234 8 8 4.05 4.05 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
558099 14 AWG 14 AWG 3 3 41 41 530 13.46 159 237 18 18 2.55 2.55 BLACK/WHITE/GREEN BLACK/WHITE/GREEN
558102 14 AWG 14 AWG 4 4 41 41 570 14.48 193 288 15 15 2.55 2.55 BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
558147 14 AWG 14 AWG 5 5 41 41 655 16.64 244 363 12 12 2.55 2.55 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
558094 12 AWG 12 AWG 3 3 65 65 606 15.39 224 334 25 25 1.61 1.61 BLACK/WHITE/GREEN BLACK/WHITE/GREEN
558095 12 AWG 12 AWG 4 4 65 65 644 16.36 267 397 20 20 1.61 1.61 BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
558104 12 AWG 12 AWG 5 5 65 65 709 18.01 296 440 16 16 1.61 1.61 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
558097 10 AWG 10 AWG 3 3 104 104 665 16.89 295 439 30 30 0.98 0.98 BLACK/WHITE/GREEN BLACK/WHITE/GREEN
558096 10 AWG 10 AWG 4 4 104 104 715 18.16 348 518 25 25 0.98 0.98 BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
558103 10 AWG 10 AWG 5 5 104 104 772 19.61 446 664 20 20 0.98 0.98 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
560039 8 AWG 8 AWG 3 3 133 133 848 21.54 427 635 40 40 0.63 0.63 BLACK/WHITE/GREEN BLACK/WHITE/GREEN
630726 8 AWG 8 AWG 4 4 133 133 954 24.23 596 887 35 35 0.63 0.63 BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
596961 8 AWG 8 AWG 5 5 133 133 1036 26.31 717 1067 28 28 0.63 0.63 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
560041 6 AWG 6 AWG 3 3 133 133 990 25.15 675 1005 55 55 0.4 0.4 BLACK/WHITE/GREEN BLACK/WHITE/GREEN
560042 6 AWG 6 AWG 4 4 133 133 1075 27.31 830 1235 45 45 0.4 0.4 BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
562068 6 AWG 6 AWG 5 5 133 133 1192 30.28 1037 1543 36 36 0.4 0.4 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
570054 4 AWG 4 AWG 3 3 427 427 1137 28.88 889 1324 70 70 0.25 0.25 BLACK/WHITE/GREEN BLACK/WHITE/GREEN
560925 4 AWG 4 AWG 4 4 427 427 1257 31.93 1116 1661 60 60 0.25 0.25 BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
562067 4 AWG 4 AWG 5 5 427 427 1395 35.45 1400 2084 48 48 0.25 0.25 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
560928 2 AWG 2 AWG 4 4 168 168 1480 37.59 1657 2467 80 80 0.016 0.016 BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
562065 2 AWG 2 AWG 5 5 168 168 1716 43.59 2006 2985 64 64 0.16 0.16 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE

Standards & References

  • UL 62
  • CSA Standard 22.2 No. 49
  • NEC 400
  • NEC 501.140 Class I Division 2
  • Passes CSA FT2 Flame Test
  • MSHA
  • Federal and Military Specification JC-580B
  • RoHS-2 (European Directive 2011/65/EU )

Construction

  • Conductors: Class K stranded bare copper per ASTM B-174
  • Insulation: EPDM
  • Jacket: Black CPE (Other colors available upon request)