600V SEOPRENE® SEOOW Cord Control with Black Jacket 105°C

600V SEOPRENE® SEOOW Cord Control with Black Jacket 105°C

600 Volt Cord. 105°C Premium Oil Resistance, Sunlight, Water Resistance and Flame Retardant
Download Category Specifications:
Excel Table

Application

Southwire Type SEOOW Flexible Cords are permitted for Indoor and outdoor temporary power uses, portable industrial machinery and compressors, food processing and washdown facilities. Type SEOOW Cords are suitable for use in temperatures between -50°C to maximum 105°C.

Specifications

measurement
imperial metric
Select a set of products below for more information:
Conductor
Size (AWG or kcmil) No. of Conductors No. of Strands Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km) Allowable Ampacity Nom. DC Resistance (Conductor) Conductor Colors
598758 18 AWG 18 AWG 6 6 16 16 484 12.29 116 173 5.5 5.5 6.4 6.4 BLACK/WHITE/RED/GREEN/ORANGE/BLUE BLACK/WHITE/RED/GREEN/ORANGE/BLUE
598728 18 AWG 18 AWG 7 7 16 16 488 12.40 124 185 4.5 4.5 6.4 6.4 BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
598729 18 AWG 18 AWG 8 8 16 16 517 13.13 138 205 4.5 4.5 6.4 6.4 BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
598730 18 AWG 18 AWG 10 10 16 16 592 15.04 166 247 3.5 3.5 6.4 6.4
598731 18 AWG 18 AWG 12 12 16 16 613 15.58 189 282 3.5 3.5 6.4 6.4
598732 18 AWG 18 AWG 14 14 16 16 640 16.26 213 317 3.5 3.5 6.4 6.4
595487 18 AWG 18 AWG 16 16 16 16 697 17.70 255 379 3.5 3.5 6.4 6.4
550464 16 AWG 16 AWG 4 4 26 26 416 10.57 93 138 10 10 4.12 4.12 BLACK/WHITE/GREEN/RED BLACK/WHITE/GREEN/RED
550555 16 AWG 16 AWG 5 5 26 26 492 12.50 129 191 8 8 4.12 4.12 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
562791 16 AWG 16 AWG 6 6 26 26 533 13.54 149 221 8 8 4.12 4.12 BLACK/WHITE/RED/GREEN/ORANGE/BLUE BLACK/WHITE/RED/GREEN/ORANGE/BLUE
595375 16 AWG 16 AWG 7 7 26 26 525 13.34 154 229 7 7 4.12 4.12 BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
589888 16 AWG 16 AWG 8 8 26 26 560 14.22 173 258 7 7 4.12 4.12 BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
598736 16 AWG 16 AWG 14 14 26 26 725 18.42 286 425 5 5 4.12 4.12
598737 16 AWG 16 AWG 16 16 26 26 757 19.23 316 470 5 5 4.12 4.12
550562 14 AWG 14 AWG 2 2 41 41 497 12.62 113 168 18 18 2.64 2.64 BLACK/WHITE BLACK/WHITE
550398 14 AWG 14 AWG 3 3 41 41 522 13.26 136 203 18 18 2.64 2.64 BLACK/WHITE/GREEN BLACK/WHITE/GREEN
550399 14 AWG 14 AWG 4 4 41 41 592 15.04 179 267 15 15 2.64 2.64 BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
598739 14 AWG 14 AWG 6 6 41 41 690 17.53 248 369 12 12 2.64 2.64 BLACK/WHITE/RED/GREEN/ORANGE/BLUE BLACK/WHITE/RED/GREEN/ORANGE/BLUE
598740 14 AWG 14 AWG 7 7 41 41 690 17.53 261 388 10 10 2.64 2.64 BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK
598741 14 AWG 14 AWG 8 8 41 41 743 18.87 297 442 10 10 2.64 2.64 BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK BLACK/WHITE/RED/GREEN/ORANGE/BLUE/WHITE-BLACK/RED-BLACK
589921 14 AWG 14 AWG 10 10 41 41 835 21.21 351 522 7 7 2.64 2.64
550432 12 AWG 12 AWG 2 2 65 65 570 14.48 157 234 25 25 1.66 1.66 BLACK/WHITE BLACK/WHITE
550395 12 AWG 12 AWG 3 3 65 65 603 15.32 193 287 25 25 1.66 1.66 BLACK/WHITE/GREEN BLACK/WHITE/GREEN
598745 12 AWG 12 AWG 6 6 65 65 745 18.92 312 465 16 16 1.66 1.66 BLACK/WHITE/RED/GREEN/ORANGE/BLUE BLACK/WHITE/RED/GREEN/ORANGE/BLUE

Standards & References

  • UL 62 Flexible Cords and Cables
  • CSA C22.2 No. 49 Flexible Cords and Cables
  • Passes CSA FT2 Flame Test
  • RoHS-2 (European Directive 2011/65/EU)
  • NEC Article 400 Flexible Cords, Cables and Fixture Wire
  • NEC Article 501.140 Class I Division 2

Construction

  • Conductor: Class K stranded bare copper per ASTM B-174
  • Insulation: Heat, moisture and oil resistant TPE
  • Filler: Non-wicking polypropylene fillers, with a tissue-paper separator wrapped around the assembly
  • Jacket: Black TPE (other colors available upon request)