Southwire Type G cable is a heavy-duty industrial cable for use in flexible, portable, and extra-hard usage applications where equipment grounding is required per NEC Article 400. Suitable for continuous submersion in water – ideal for submersible pumps, marine application. Also suitable for use in light to medium-duty mining applications. Sunlight and oil resistant. Highly flexible and easy to work with in cold conditions. Not for use as permanent building wiring. Meets FT-5 Flame Test. cUL Listed.
Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Inner Layer Thickness (mils) (mm) | Outer Layer Thickness (mils) (mm) | Approx. OD (in) (cm) | Approx. Weight (lbs/1000') (kgs/km) | |
More Options |
8 AWG
8 AWG
|
4.0
4.0
|
71
71
|
0.145
0.37
|
60
1.52
|
145
3.68
|
0.985
2.50
|
629
936
|
More Options |
6 AWG
6 AWG
|
4.0
4.0
|
65
65
|
0.186
0.47
|
60
1.52
|
145
3.68
|
1.130
2.87
|
865
1287
|
More Options |
2 AWG
2 AWG
|
4.0
4.0
|
168
168
|
0.290
0.74
|
60
1.52
|
205
5.21
|
1.479
3.76
|
1882
2801
|
More Options |
1 AWG
1 AWG
|
4.0
4.0
|
224
224
|
0.300
0.76
|
80
2.03
|
145
3.68
|
1.591
4.04
|
2063
3070
|
More Options |
1/0 AWG
1/0 AWG
|
4.0
4.0
|
259
259
|
0.379
0.96
|
80
2.03
|
155
3.94
|
1.755
4.46
|
2452
3649
|
More Options |
2/0 AWG
2/0 AWG
|
4.0
4.0
|
324
324
|
0.400
1.02
|
80
2.03
|
155
3.94
|
1.930
4.90
|
3057
4549
|
More Options |
3/0 AWG
3/0 AWG
|
4.0
4.0
|
418
418
|
0.480
1.22
|
80
2.03
|
155
3.94
|
2.048
5.20
|
3679
5475
|
More Options |
4/0 AWG
4/0 AWG
|
4.0
4.0
|
532
532
|
0.530
1.35
|
80
2.03
|
155
3.94
|
2.175
5.52
|
4392
6536
|
More Options |
250 KCMIL
250 KCMIL
|
4.0
4.0
|
608
608
|
0.605
1.54
|
95
2.41
|
270
6.86
|
2.527
6.42
|
5609
8347
|
More Options |
350 KCMIL
350 KCMIL
|
4.0
4.0
|
893
893
|
0.670
1.70
|
95
2.41
|
270
6.86
|
2.972
7.55
|
8110
12069
|
More Options |
500 KCMIL
500 KCMIL
|
4.0
4.0
|
1221
1221
|
0.858
2.18
|
95
2.41
|
325
8.26
|
3.230
8.20
|
10201
15181
|
Cond. Size | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | Min. Bend Radius (in) (cm) | Allowable Ampacity In Air 60C | Allowable Ampacity In Air 75C | Allowable Ampacity In Air 90C | |
More Options |
8 AWG
8 AWG
|
0.679
1.01
|
0.818
1.22
|
0.052
0.08
|
3.9
9.91
|
38
38
|
46
46
|
52
52
|
More Options |
6 AWG
6 AWG
|
0.435
0.65
|
0.524
0.78
|
0.051
0.08
|
5.6
14.22
|
50
50
|
62
62
|
70
70
|
More Options |
2 AWG
2 AWG
|
0.172
0.26
|
0.207
0.31
|
0.045
0.07
|
7.3
18.54
|
90
90
|
106
106
|
122
122
|
More Options |
1 AWG
1 AWG
|
0.137
0.20
|
0.164
0.24
|
0.046
0.07
|
7.9
20.07
|
105
105
|
125
125
|
142
142
|
More Options |
1/0 AWG
1/0 AWG
|
0.109
0.16
|
0.131
0.19
|
0.044
0.07
|
8.7
22.10
|
121
121
|
145
145
|
164
164
|
More Options |
2/0 AWG
2/0 AWG
|
0.087
0.13
|
0.104
0.15
|
0.043
0.06
|
9.6
24.38
|
139
139
|
166
166
|
190
190
|
More Options |
3/0 AWG
3/0 AWG
|
0.069
0.10
|
0.083
0.12
|
0.042
0.06
|
12.2
30.99
|
161
161
|
193
193
|
219
219
|
More Options |
4/0 AWG
4/0 AWG
|
0.055
0.08
|
0.067
0.10
|
0.041
0.06
|
13.0
33.02
|
186
186
|
222
222
|
253
253
|
More Options |
250 KCMIL
250 KCMIL
|
0.047
0.07
|
0.057
0.08
|
0.041
0.06
|
15.1
38.35
|
207
207
|
248
248
|
282
282
|
More Options |
350 KCMIL
350 KCMIL
|
0.033
0.05
|
0.042
0.06
|
0.040
0.06
|
17.8
45.21
|
254
254
|
305
305
|
346
346
|
More Options |
500 KCMIL
500 KCMIL
|
0.023
0.03
|
0.031
0.05
|
0.039
0.06
|
19.3
49.02
|
314
314
|
376
376
|
429
429
|
* Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center.