Southwire’s 600 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 75°C in wet locations and 90°C in dry locations, 105°C for emergency overload, and 150°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Sunlight Resistant - For Direct Burial - Silicone Free - VW-1 Rated.
Cond. Size | Conductor Number | Cond. Strands | Inner Layer Thickness (mils) (mm) | Outer Layer Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Min. Bend Radius (in) (cm) | Allowable Ampacity Raceway 75C | Allowable Ampacity Raceway 90C | |
More Options |
16 AWG
16 AWG
|
2.0
2.0
|
26
26
|
20
0.51
|
45
1.14
|
0.292
0.74
|
16
24
|
44
65
|
4.181
6.22
|
5.037
7.50
|
1.2
3.05
|
-
-
|
18
18
|
More Options |
16 AWG
16 AWG
|
3.0
3.0
|
26
26
|
20
0.51
|
45
1.14
|
0.308
0.78
|
24
36
|
58
86
|
4.181
6.22
|
5.037
7.50
|
1.2
3.05
|
-
-
|
18
18
|
More Options |
16 AWG
16 AWG
|
4.0
4.0
|
26
26
|
20
0.51
|
45
1.14
|
0.333
0.85
|
32
48
|
70
104
|
4.181
6.22
|
5.037
7.50
|
1.3
3.30
|
-
-
|
14
14
|
More Options |
16 AWG
16 AWG
|
5.0
5.0
|
26
26
|
20
0.51
|
45
1.14
|
0.362
0.92
|
40
60
|
81
121
|
4.181
6.22
|
5.037
7.50
|
1.4
3.56
|
-
-
|
14
14
|
More Options |
16 AWG
16 AWG
|
7.0
7.0
|
26
26
|
20
0.51
|
45
1.14
|
0.393
1.00
|
55
82
|
107
159
|
4.181
6.22
|
5.037
7.50
|
1.6
4.06
|
-
-
|
12
12
|
More Options |
16 AWG
16 AWG
|
9.0
9.0
|
26
26
|
20
0.51
|
45
1.14
|
0.454
1.15
|
72
107
|
135
201
|
4.181
6.22
|
5.037
7.50
|
1.8
4.57
|
-
-
|
12
12
|
More Options |
16 AWG
16 AWG
|
12.0
12.0
|
26
26
|
20
0.51
|
45
1.14
|
0.510
1.30
|
95
141
|
174
259
|
4.181
6.22
|
5.037
7.50
|
2.0
5.08
|
-
-
|
9
9
|
More Options |
16 AWG
16 AWG
|
15.0
15.0
|
26
26
|
20
0.51
|
45
1.14
|
0.595
1.51
|
120
179
|
226
336
|
4.181
6.22
|
5.037
7.50
|
2.4
6.10
|
-
-
|
9
9
|
More Options |
16 AWG
16 AWG
|
19.0
19.0
|
26
26
|
20
0.51
|
60
1.52
|
0.625
1.59
|
152
226
|
274
408
|
4.181
6.22
|
5.037
7.50
|
2.5
6.35
|
-
-
|
9
9
|
More Options |
16 AWG
16 AWG
|
25.0
25.0
|
26
26
|
20
0.51
|
60
1.52
|
0.700
1.78
|
201
299
|
350
521
|
4.181
6.22
|
5.037
7.50
|
2.8
7.11
|
-
-
|
8
8
|
More Options |
16 AWG
16 AWG
|
30.0
30.0
|
26
26
|
20
0.51
|
60
1.52
|
0.767
1.95
|
242
360
|
412
613
|
4.181
6.22
|
5.037
7.50
|
3.1
7.87
|
-
-
|
8
8
|
More Options |
16 AWG
16 AWG
|
37.0
37.0
|
26
26
|
20
0.51
|
60
1.52
|
0.867
2.20
|
297
442
|
529
787
|
4.181
6.22
|
5.037
7.50
|
3.5
8.89
|
-
-
|
7
7
|
More Options |
14 AWG
14 AWG
|
2.0
2.0
|
7
7
|
20
0.51
|
45
1.14
|
0.305
0.77
|
25
37
|
56
83
|
2.631
3.92
|
3.170
4.72
|
1.2
3.05
|
20
20
|
25
25
|
More Options |
14 AWG
14 AWG
|
3.0
3.0
|
7
7
|
20
0.51
|
45
1.14
|
0.322
0.82
|
38
57
|
74
110
|
2.631
3.92
|
3.170
4.72
|
1.3
3.30
|
20
20
|
25
25
|
More Options |
14 AWG
14 AWG
|
4.0
4.0
|
7
7
|
20
0.51
|
45
1.14
|
0.351
0.89
|
51
76
|
94
140
|
2.631
3.92
|
3.170
4.72
|
1.4
3.56
|
16
16
|
20
20
|
More Options |
14 AWG
14 AWG
|
5.0
5.0
|
7
7
|
20
0.51
|
45
1.14
|
0.380
0.97
|
64
95
|
109
162
|
2.631
3.92
|
3.170
4.72
|
1.5
3.81
|
16
16
|
20
20
|
More Options |
14 AWG
14 AWG
|
6.0
6.0
|
7
7
|
20
0.51
|
45
1.14
|
0.416
1.06
|
76
113
|
130
193
|
2.631
3.92
|
3.170
4.72
|
1.7
4.32
|
16
16
|
20
20
|
More Options |
14 AWG
14 AWG
|
9.0
9.0
|
7
7
|
20
0.51
|
45
1.14
|
0.490
1.24
|
115
171
|
189
281
|
2.631
3.92
|
3.170
4.72
|
2.0
5.08
|
14
14
|
17
17
|
More Options |
14 AWG
14 AWG
|
10.0
10.0
|
7
7
|
20
0.51
|
45
1.14
|
0.556
1.41
|
128
190
|
222
330
|
2.631
3.92
|
3.170
4.72
|
2.2
5.59
|
10
10
|
12
12
|
More Options |
14 AWG
14 AWG
|
12.0
12.0
|
7
7
|
20
0.51
|
45
1.14
|
0.573
1.46
|
153
228
|
256
381
|
2.631
3.92
|
3.170
4.72
|
2.3
5.84
|
10
10
|
12
12
|
More Options |
14 AWG
14 AWG
|
15.0
15.0
|
7
7
|
20
0.51
|
60
1.52
|
0.632
1.61
|
192
286
|
312
464
|
2.631
3.92
|
3.170
4.72
|
2.5
6.35
|
10
10
|
12
12
|
More Options |
14 AWG
14 AWG
|
19.0
19.0
|
7
7
|
20
0.51
|
60
1.52
|
0.664
1.69
|
243
362
|
381
567
|
2.631
3.92
|
3.170
4.72
|
2.7
6.86
|
10
10
|
12
12
|
More Options |
14 AWG
14 AWG
|
20.0
20.0
|
7
7
|
20
0.51
|
60
1.52
|
0.697
1.77
|
256
381
|
401
597
|
2.631
3.92
|
3.170
4.72
|
2.8
7.11
|
10
10
|
12
12
|
More Options |
14 AWG
14 AWG
|
25.0
25.0
|
7
7
|
20
0.51
|
60
1.52
|
0.802
2.04
|
320
476
|
507
754
|
2.631
3.92
|
3.170
4.72
|
3.2
8.13
|
9
9
|
11
11
|
More Options |
14 AWG
14 AWG
|
37.0
37.0
|
7
7
|
20
0.51
|
80
2.03
|
0.949
2.41
|
475
707
|
759
1130
|
2.631
3.92
|
3.170
4.72
|
3.8
9.65
|
8
8
|
10
10
|
More Options |
12 AWG
12 AWG
|
2.0
2.0
|
7
7
|
20
0.51
|
45
1.14
|
0.348
0.88
|
40
60
|
77
115
|
1.662
2.47
|
2.002
2.98
|
1.4
3.56
|
25
25
|
30
30
|
More Options |
12 AWG
12 AWG
|
3.0
3.0
|
7
7
|
20
0.51
|
45
1.14
|
0.369
0.94
|
61
91
|
108
161
|
1.662
2.47
|
2.002
2.98
|
1.5
3.81
|
25
25
|
30
30
|
More Options |
12 AWG
12 AWG
|
4.0
4.0
|
7
7
|
20
0.51
|
45
1.14
|
0.401
1.02
|
81
121
|
149
222
|
1.662
2.47
|
2.002
2.98
|
1.6
4.06
|
20
20
|
24
24
|
More Options |
12 AWG
12 AWG
|
5.0
5.0
|
7
7
|
20
0.51
|
45
1.14
|
0.438
1.11
|
101
150
|
183
272
|
1.662
2.47
|
2.002
2.98
|
1.8
4.57
|
20
20
|
24
24
|
More Options |
12 AWG
12 AWG
|
6.0
6.0
|
7
7
|
20
0.51
|
45
1.14
|
0.481
1.22
|
122
182
|
189
281
|
1.662
2.47
|
2.002
2.98
|
1.9
4.83
|
20
20
|
24
24
|
More Options |
12 AWG
12 AWG
|
7.0
7.0
|
7
7
|
20
0.51
|
45
1.14
|
0.477
1.21
|
142
211
|
237
353
|
1.662
2.47
|
2.002
2.98
|
1.9
4.83
|
17
17
|
21
21
|
More Options |
12 AWG
12 AWG
|
9.0
9.0
|
7
7
|
20
0.51
|
60
1.52
|
0.580
1.47
|
183
272
|
332
494
|
1.662
2.47
|
2.002
2.98
|
2.3
5.84
|
17
17
|
21
21
|
More Options |
12 AWG
12 AWG
|
12.0
12.0
|
7
7
|
20
0.51
|
60
1.52
|
0.657
1.67
|
244
363
|
425
632
|
1.662
2.47
|
2.002
2.98
|
2.6
6.60
|
12
12
|
15
15
|
More Options |
12 AWG
12 AWG
|
15.0
15.0
|
7
7
|
20
0.51
|
60
1.52
|
0.734
1.86
|
305
454
|
454
676
|
1.662
2.47
|
2.002
2.98
|
2.9
7.37
|
12
12
|
15
15
|
More Options |
12 AWG
12 AWG
|
19.0
19.0
|
7
7
|
20
0.51
|
60
1.52
|
0.772
1.96
|
388
577
|
562
836
|
1.662
2.47
|
2.002
2.98
|
3.1
7.87
|
12
12
|
15
15
|
More Options |
12 AWG
12 AWG
|
25.0
25.0
|
7
7
|
20
0.51
|
80
2.03
|
0.943
2.40
|
509
757
|
761
1132
|
1.662
2.47
|
2.002
2.98
|
3.8
9.65
|
11
11
|
13
13
|
More Options |
12 AWG
12 AWG
|
37.0
37.0
|
7
7
|
20
0.51
|
80
2.03
|
1.064
2.70
|
755
1124
|
1084
1613
|
1.662
2.47
|
2.002
2.98
|
5.3
13.46
|
10
10
|
12
12
|
More Options |
10 AWG
10 AWG
|
2.0
2.0
|
7
7
|
25
0.64
|
45
1.14
|
0.420
1.07
|
64
95
|
115
171
|
1.040
1.55
|
1.253
1.86
|
1.7
4.32
|
35
35
|
40
40
|
More Options |
10 AWG
10 AWG
|
3.0
3.0
|
7
7
|
25
0.64
|
45
1.14
|
0.446
1.13
|
97
144
|
159
237
|
1.040
1.55
|
1.253
1.86
|
1.8
4.57
|
35
35
|
40
40
|
More Options |
10 AWG
10 AWG
|
4.0
4.0
|
7
7
|
25
0.64
|
45
1.14
|
0.505
1.28
|
129
192
|
207
308
|
1.040
1.55
|
1.253
1.86
|
2.0
5.08
|
28
28
|
32
32
|
More Options |
10 AWG
10 AWG
|
5.0
5.0
|
7
7
|
25
0.64
|
45
1.14
|
0.565
1.44
|
161
240
|
258
384
|
1.040
1.55
|
1.253
1.86
|
2.3
5.84
|
28
28
|
32
32
|
More Options |
10 AWG
10 AWG
|
7.0
7.0
|
7
7
|
25
0.64
|
60
1.52
|
0.615
1.56
|
226
336
|
381
567
|
1.040
1.55
|
1.253
1.86
|
2.5
6.35
|
24
24
|
28
28
|
More Options |
10 AWG
10 AWG
|
9.0
9.0
|
7
7
|
25
0.64
|
60
1.52
|
0.715
1.82
|
291
433
|
501
746
|
1.040
1.55
|
1.253
1.86
|
2.9
7.37
|
24
24
|
28
28
|
More Options |
10 AWG
10 AWG
|
12.0
12.0
|
7
7
|
25
0.64
|
60
1.52
|
0.806
2.05
|
388
577
|
652
970
|
1.040
1.55
|
1.253
1.86
|
3.2
8.13
|
17
17
|
20
20
|
More Options |
10 AWG
10 AWG
|
19.0
19.0
|
7
7
|
25
0.64
|
80
2.03
|
0.993
2.52
|
613
912
|
903
1344
|
1.040
1.55
|
1.253
1.86
|
4.0
10.16
|
17
17
|
20
20
|
* Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections 310.15 and 110.14(C) for additional requirements.
* Ampacities have been adjusted for more than Three Current-Carrying Conductors.