Suitable for installation in Cable Trays and Underground Duct Banks - As per CE Code limitations (see Rule 12-2202) for grounding and bonding applications.
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Drain Wire | Diameter Over Shield (in) (cm) | Inner Jacket Thickness (mils) (mm) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | |
649033 |
6
6
|
1.0
1.0
|
7
7
|
0.177
0.45
|
60
1.52
|
|
|
|
|
|
|
|
0.300
0.76
|
81
121
|
|
108
161
|
649039 |
2
2
|
1.0
1.0
|
7
7
|
0.282
0.72
|
60
1.52
|
|
|
|
|
|
|
|
0.403
1.02
|
204
304
|
|
245
365
|
649041 |
2/0
2/0
|
1.0
1.0
|
19
19
|
0.405
1.03
|
80
2.03
|
|
|
|
|
|
|
|
0.574
1.46
|
410
610
|
|
487
725
|
649043 |
4/0
4/0
|
1.0
1.0
|
19
19
|
0.512
1.30
|
80
2.03
|
|
|
|
|
|
|
|
0.666
1.69
|
653
972
|
|
745
1109
|
649054 |
350
350
|
1.0
1.0
|
37
37
|
0.661
1.68
|
95
2.41
|
|
|
|
|
|
|
|
0.841
2.14
|
1080
1607
|
|
1218
1813
|
649056 |
500
500
|
1.0
1.0
|
37
37
|
0.789
2.00
|
95
2.41
|
|
|
|
|
|
|
|
0.966
2.45
|
1543
2296
|
|
1705
2537
|
649058 |
750
750
|
1.0
1.0
|
61
61
|
0.968
2.46
|
110
2.79
|
|
|
|
|
|
|
|
1.200
3.05
|
2315
3445
|
|
2549
3793
|
649060 |
1000
1000
|
1.0
1.0
|
61
61
|
1.117
2.84
|
110
2.79
|
|
|
|
|
|
|
|
1.349
3.43
|
3087
4594
|
|
3354
4991
|
649054 |
350
350
|
1.0
1.0
|
37
37
|
0.661
1.68
|
95
2.41
|
|
|
|
|
|
|
|
0.841
2.14
|
1080
1607
|
|
1218
1813
|
Cond. Size (AWG/Kcmil) | Conductor Number | Min. Bend Radius (in) (cm) | Max Pull Tension (lbs) (kg) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Capacitive Reactance (Mohms x 1000ft) (Mohms x km) | Inductive Reactance (ohms/1000') (ohms/km) | Shield Short Circuit Current 6 Cycles (amps) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
649033 |
6
6
|
1.0
1.0
|
1.2
3.05
|
209
94.80
|
0.411
0.61
|
0.495
0.74
|
|
0.051
0.08
|
|
65
65
|
75
75
|
649039 |
2
2
|
1.0
1.0
|
1.6
4.06
|
530
240.40
|
0.162
0.24
|
0.195
0.29
|
|
0.045
0.07
|
|
115
115
|
130
130
|
649041 |
2/0
2/0
|
1.0
1.0
|
2.2
5.59
|
1064
482.62
|
0.081
0.12
|
0.097
0.14
|
|
0.043
0.06
|
|
175
175
|
195
195
|
649043 |
4/0
4/0
|
1.0
1.0
|
2.6
6.60
|
1692
767.48
|
0.051
0.08
|
0.062
0.09
|
|
0.041
0.06
|
|
230
230
|
260
260
|
649054 |
350
350
|
1.0
1.0
|
3.3
8.38
|
2800
1270.06
|
0.031
0.05
|
0.039
0.06
|
|
0.04
0.06
|
|
310
310
|
350
350
|
649056 |
500
500
|
1.0
1.0
|
3.8
9.65
|
4000
1814.37
|
0.022
0.03
|
0.029
0.04
|
|
0.039
0.06
|
|
380
380
|
430
430
|
649058 |
750
750
|
1.0
1.0
|
6.0
15.24
|
6000
2721.55
|
0.014
0.02
|
0.022
0.03
|
|
0.038
0.06
|
|
475
475
|
535
535
|
649060 |
1000
1000
|
1.0
1.0
|
6.7
17.02
|
8000
3628.74
|
0.011
0.02
|
0.018
0.03
|
|
0.037
0.06
|
|
545
545
|
615
615
|
649054 |
350
350
|
1.0
1.0
|
3.3
8.38
|
2800
1270.06
|
0.031
0.05
|
0.039
0.06
|
|
0.04
0.06
|
|
310
310
|
350
350
|