Southwire’s 600 Volt power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. CT Rated 1/0 and Larger - Sunlight Resistant - For Direct Burial - Silicone Free
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Drain Wire | Diameter Over Shield (in) (cm) | Inner Jacket Thickness (mils) (mm) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | |
576142 |
1/0
1/0
|
1.0
1.0
|
10
10
|
0.336
0.85
|
80
2.03
|
|
|
|
|
|
|
|
0.504
1.28
|
|
99
147
|
165
246
|
575991 |
4/0
4/0
|
1.0
1.0
|
19
19
|
0.474
1.20
|
80
2.03
|
|
|
|
|
|
|
|
0.643
1.63
|
|
199
296
|
293
436
|
576787 |
250
250
|
1.0
1.0
|
35
35
|
0.520
1.32
|
95
2.41
|
|
|
|
|
|
|
|
0.720
1.83
|
|
235
350
|
357
531
|
576137 |
350
350
|
1.0
1.0
|
35
35
|
0.615
1.56
|
95
2.41
|
|
|
|
|
|
|
|
0.816
2.07
|
|
329
490
|
471
701
|
567324 |
500
500
|
1.0
1.0
|
35
35
|
0.735
1.87
|
95
2.41
|
|
|
|
|
|
|
|
0.936
2.38
|
|
471
701
|
630
938
|
576219 |
750
750
|
1.0
1.0
|
58
58
|
0.908
2.31
|
110
2.79
|
|
|
|
|
|
|
|
1.140
2.90
|
|
706
1051
|
936
1393
|
Cond. Size (AWG/Kcmil) | Conductor Number | Min. Bend Radius (in) (cm) | Max Pull Tension (lbs) (kg) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Capacitive Reactance (Mohms x 1000ft) (Mohms x km) | Inductive Reactance (ohms/1000') (ohms/km) | Shield Short Circuit Current 6 Cycles (amps) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
576142 |
1/0
1/0
|
1.0
1.0
|
2.0
5.08
|
633
287.12
|
0.168
0.25
|
0.201
0.30
|
|
0.044
0.07
|
|
120
120
|
135
135
|
575991 |
4/0
4/0
|
1.0
1.0
|
2.5
6.35
|
1269
575.61
|
0.084
0.13
|
0.1
0.15
|
|
0.041
0.06
|
|
180
180
|
205
205
|
576787 |
250
250
|
1.0
1.0
|
2.8
7.11
|
1500
680.39
|
0.071
0.11
|
0.086
0.13
|
|
0.041
0.06
|
|
205
205
|
230
230
|
576137 |
350
350
|
1.0
1.0
|
3.2
8.13
|
2100
952.54
|
0.05
0.07
|
0.062
0.09
|
|
0.04
0.06
|
|
250
250
|
280
280
|
567324 |
500
500
|
1.0
1.0
|
3.7
9.40
|
3000
1360.78
|
0.035
0.05
|
0.044
0.07
|
|
0.039
0.06
|
|
310
310
|
350
350
|
576219 |
750
750
|
1.0
1.0
|
5.7
14.48
|
4500
2041.16
|
0.024
0.04
|
0.031
0.05
|
|
0.038
0.06
|
|
385
385
|
435
435
|