Southwire’s Machine Flex® control tray cables 600/1000 Volt conform to NFPA 79 and are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 75°C in wet locations and 90°C in dry locations, 130°C for emergency overload, and 150°C for short circuit conditions. For uses in Class I, II, Division 2 hazardous locations per NEC® Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC® 336.10. Southwire’s machine tray cable is ideal for use in CNC machines, grinding, cutting, metal forming, buffing, bottling equipment, conveyors, processing & packaging equipment, assembly lines, control panels, food and beverage, oil sands, plant expansion, wind energy and data centers. Multiple approvals for multiple applications. Cable is rated for -40°C cold impact. Two conductor cables contain no green/yellow ground.
Conductor | Ground Wire | ||||||||
No. of Conductors | Size (AWG or kcmil) (mm2) | No. of Strands | Insulation Thickness (mils) (mm) | Size (AWG) | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity | |
677071 |
2
2
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
266
6.76
|
35
53
|
|
581511 |
3
3
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
281
7.14
|
50
74
|
|
582642 |
4
4
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
306
7.77
|
55
81
|
|
582644 |
5
5
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
332
8.43
|
74
110
|
|
581513 |
7
7
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
358
9.09
|
91
136
|
|
582645 |
9
9
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
411
10.44
|
121
181
|
|
582646 |
12
12
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
456
11.58
|
128
191
|
|
582647 |
18
18
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
554
14.07
|
226
336
|
|
646262 |
19
19
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
560
14.22
|
201
299
|
|
581514 |
25
25
|
18 AWG
18 AWG
|
16
16
|
15
0.38
|
|
|
635
16.13
|
254
377
|
|
582648 |
4
4
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
339
8.61
|
71
106
|
|
677072 |
2
2
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
294
7.47
|
45
67
|
|
581515 |
3
3
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
311
7.90
|
58
87
|
|
582648 |
4
4
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
339
8.61
|
71
106
|
|
582649 |
5
5
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
370
9.40
|
86
129
|
|
581516 |
7
7
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
400
10.16
|
122
182
|
|
582651 |
9
9
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
462
11.73
|
163
243
|
|
582652 |
12
12
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
509
12.93
|
175
260
|
|
582653 |
18
18
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
623
15.82
|
305
454
|
|
646263 |
19
19
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
630
16.00
|
272
405
|
|
581517 |
24
24
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
736
18.69
|
347
516
|
|
581517 |
25
25
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
717
18.21
|
346
514
|
|
581518 |
41
41
|
16 AWG
16 AWG
|
26
26
|
15
0.38
|
|
|
948
24.08
|
592
880
|
|
677073 |
2
2
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
324
8.23
|
59
88
|
|
581519 |
3
3
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
342
8.69
|
77
115
|
|
582654 |
4
4
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
375
9.53
|
97
144
|
|
582655 |
5
5
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
411
10.44
|
116
173
|
|
581521 |
7
7
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
445
11.30
|
150
223
|
|
582656 |
9
9
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
516
13.11
|
221
329
|
|
582657 |
12
12
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
608
15.45
|
258
383
|
|
582658 |
18
18
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
697
17.70
|
417
621
|
|
581522 |
25
25
|
14 AWG
14 AWG
|
41
41
|
15
0.38
|
|
|
806
20.47
|
487
725
|
|
677074 |
2
2
|
12 AWG
12 AWG
|
65
65
|
15
0.38
|
|
|
362
9.19
|
81
120
|
|
677188 |
3
3
|
12 AWG
12 AWG
|
65
65
|
15
0.38
|
|
|
389
9.89
|
108
161
|
|
582659 |
4
4
|
12 AWG
12 AWG
|
65
65
|
15
0.38
|
|
|
420
10.67
|
137
204
|
|
582660 |
5
5
|
12 AWG
12 AWG
|
65
65
|
15
0.38
|
|
|
502
12.75
|
208
309
|
|
582661 |
7
7
|
12 AWG
12 AWG
|
65
65
|
15
0.38
|
|
|
502
12.75
|
244
363
|
|
677075 |
2
2
|
10 AWG
10 AWG
|
105
105
|
20
0.51
|
|
|
430
10.92
|
119
178
|
|
677189 |
3
3
|
10 AWG
10 AWG
|
105
105
|
20
0.51
|
|
|
462
11.76
|
160
238
|
|
581523 |
4
4
|
10 AWG
10 AWG
|
105
105
|
20
0.51
|
|
|
502
12.75
|
203
302
|
|
582662 |
5
5
|
10 AWG
10 AWG
|
105
105
|
20
0.51
|
|
|
579
14.72
|
291
434
|
|
582663 |
7
7
|
10 AWG
10 AWG
|
105
105
|
20
0.51
|
|
|
628
15.95
|
371
552
|
|
677190 |
3
3
|
8 AWG
8 AWG
|
168
168
|
30
0.76
|
|
|
626
15.91
|
314
468
|
|
643367 |
4
4
|
8 AWG
8 AWG
|
168
168
|
30
0.76
|
8
8
|
|
680
17.27
|
361
538
|
|
677191 |
3
3
|
6 AWG
6 AWG
|
259
259
|
30
0.76
|
6
6
|
|
725
18.43
|
441
656
|
|
643369 |
4
4
|
6 AWG
6 AWG
|
259
259
|
30
0.76
|
6
6
|
|
817
20.75
|
562
837
|
|
677192 |
3
3
|
4 AWG
4 AWG
|
420
420
|
40
1.02
|
4
4
|
|
889
22.60
|
650
967
|
|
643371 |
4
4
|
4 AWG
4 AWG
|
420
420
|
40
1.02
|
4
4
|
|
969
24.61
|
830
1234
|
|
677193 |
3
3
|
2 AWG
2 AWG
|
651
651
|
40
1.02
|
2
2
|
|
1070
27.18
|
989
1471
|
|
643373 |
4
4
|
2 AWG
2 AWG
|
651
651
|
40
1.02
|
2
2
|
|
1196
30.38
|
1262
1879
|
|
581514 |
|
18 null
18 null
|
16
16
|
15
0.38
|
|
|
640
16.26
|
245
365
|
|
582656 |
|
null null
null null
|
|
|
|
|
|
|
|