Southwire’s 600 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 75°C in wet locations and 90°C in dry locations, 105°C for emergency overload, and 150°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Sunlight Resistant - For Direct Burial - Silicone Free - VW-1 Rated.
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Color | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Min. Bend Radius (in) (cm) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
604843 |
16
16
|
2.0
2.0
|
26
26
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.292
0.74
|
16
24
|
|
44
65
|
4.181
6.22
|
5.037
7.50
|
1.2
3.05
|
-
-
|
18
18
|
604850 |
16
16
|
3.0
3.0
|
26
26
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.308
0.78
|
24
36
|
|
58
86
|
4.181
6.22
|
5.037
7.50
|
1.2
3.05
|
-
-
|
18
18
|
604868 |
16
16
|
4.0
4.0
|
26
26
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.333
0.85
|
32
48
|
|
70
104
|
4.181
6.22
|
5.037
7.50
|
1.3
3.30
|
-
-
|
14
14
|
604876 |
16
16
|
5.0
5.0
|
26
26
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.362
0.92
|
40
60
|
|
81
121
|
4.181
6.22
|
5.037
7.50
|
1.4
3.56
|
-
-
|
14
14
|
604892 |
16
16
|
7.0
7.0
|
26
26
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.393
1.00
|
55
82
|
|
107
159
|
4.181
6.22
|
5.037
7.50
|
1.6
4.06
|
-
-
|
12
12
|
604918 |
16
16
|
9.0
9.0
|
26
26
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.454
1.15
|
72
107
|
|
135
201
|
4.181
6.22
|
5.037
7.50
|
1.8
4.57
|
-
-
|
12
12
|
604942 |
16
16
|
12.0
12.0
|
26
26
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.510
1.30
|
95
141
|
|
174
259
|
4.181
6.22
|
5.037
7.50
|
2.0
5.08
|
-
-
|
9
9
|
604975 |
16
16
|
15.0
15.0
|
26
26
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.595
1.51
|
120
179
|
|
226
336
|
4.181
6.22
|
5.037
7.50
|
2.4
6.10
|
-
-
|
9
9
|
605014 |
16
16
|
19.0
19.0
|
26
26
|
|
|
20
0.51
|
|
|
|
60
1.52
|
0.625
1.59
|
152
226
|
|
274
408
|
4.181
6.22
|
5.037
7.50
|
2.5
6.35
|
-
-
|
9
9
|
605071 |
16
16
|
25.0
25.0
|
26
26
|
|
|
20
0.51
|
|
|
|
60
1.52
|
0.700
1.78
|
201
299
|
|
350
521
|
4.181
6.22
|
5.037
7.50
|
2.8
7.11
|
-
-
|
8
8
|
605121 |
16
16
|
30.0
30.0
|
26
26
|
|
|
20
0.51
|
|
|
|
60
1.52
|
0.767
1.95
|
242
360
|
|
412
613
|
4.181
6.22
|
5.037
7.50
|
3.1
7.87
|
-
-
|
8
8
|
605196 |
16
16
|
37.0
37.0
|
26
26
|
|
|
20
0.51
|
|
|
|
60
1.52
|
0.867
2.20
|
297
442
|
|
529
787
|
4.181
6.22
|
5.037
7.50
|
3.5
8.89
|
-
-
|
7
7
|
408484 |
14
14
|
2.0
2.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.305
0.77
|
25
37
|
|
56
83
|
2.631
3.92
|
3.17
4.72
|
1.2
3.05
|
20
20
|
25
25
|
408518 |
14
14
|
3.0
3.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.322
0.82
|
38
57
|
|
74
110
|
2.631
3.92
|
3.17
4.72
|
1.3
3.30
|
20
20
|
25
25
|
408542 |
14
14
|
4.0
4.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.351
0.89
|
51
76
|
|
94
140
|
2.631
3.92
|
3.17
4.72
|
1.4
3.56
|
16
16
|
20
20
|
408575 |
14
14
|
5.0
5.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.380
0.97
|
64
95
|
|
109
162
|
2.631
3.92
|
3.17
4.72
|
1.5
3.81
|
16
16
|
20
20
|
608836 |
14
14
|
6.0
6.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.416
1.06
|
76
113
|
|
130
193
|
2.631
3.92
|
3.17
4.72
|
1.7
4.32
|
16
16
|
20
20
|
408740 |
14
14
|
9.0
9.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.490
1.24
|
115
171
|
|
189
281
|
2.631
3.92
|
3.17
4.72
|
2.0
5.08
|
14
14
|
17
17
|
605477 |
14
14
|
10.0
10.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.556
1.41
|
128
190
|
|
222
330
|
2.631
3.92
|
3.17
4.72
|
2.2
5.59
|
10
10
|
12
12
|
408807 |
14
14
|
12.0
12.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.573
1.46
|
153
228
|
|
256
381
|
2.631
3.92
|
3.17
4.72
|
2.3
5.84
|
10
10
|
12
12
|
412874 |
14
14
|
15.0
15.0
|
7
7
|
|
|
20
0.51
|
|
|
|
60
1.52
|
0.632
1.61
|
192
286
|
|
312
464
|
2.631
3.92
|
3.17
4.72
|
2.5
6.35
|
10
10
|
12
12
|
412908 |
14
14
|
19.0
19.0
|
7
7
|
|
|
20
0.51
|
|
|
|
60
1.52
|
0.664
1.69
|
243
362
|
|
381
567
|
2.631
3.92
|
3.17
4.72
|
2.7
6.86
|
10
10
|
12
12
|
608729 |
14
14
|
20.0
20.0
|
7
7
|
|
|
20
0.51
|
|
|
|
60
1.52
|
0.697
1.77
|
256
381
|
|
401
597
|
2.631
3.92
|
3.17
4.72
|
2.8
7.11
|
10
10
|
12
12
|
552133 |
14
14
|
25.0
25.0
|
7
7
|
|
|
20
0.51
|
|
|
|
60
1.52
|
0.802
2.04
|
320
476
|
|
507
754
|
2.631
3.92
|
3.17
4.72
|
3.2
8.13
|
9
9
|
11
11
|
552190 |
14
14
|
37.0
37.0
|
7
7
|
|
|
20
0.51
|
|
|
|
80
2.03
|
0.949
2.41
|
475
707
|
|
759
1130
|
2.631
3.92
|
3.17
4.72
|
3.8
9.65
|
8
8
|
10
10
|
408468 |
12
12
|
2.0
2.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.348
0.88
|
40
60
|
|
77
115
|
1.662
2.47
|
2.002
2.98
|
1.4
3.56
|
25
25
|
30
30
|
408526 |
12
12
|
3.0
3.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.369
0.94
|
61
91
|
|
108
161
|
1.662
2.47
|
2.002
2.98
|
1.5
3.81
|
25
25
|
30
30
|
408559 |
12
12
|
4.0
4.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.401
1.02
|
81
121
|
|
149
222
|
1.662
2.47
|
2.002
2.98
|
1.6
4.06
|
20
20
|
24
24
|
408583 |
12
12
|
5.0
5.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.438
1.11
|
101
150
|
|
183
272
|
1.662
2.47
|
2.002
2.98
|
1.8
4.57
|
20
20
|
24
24
|
608737 |
12
12
|
6.0
6.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.481
1.22
|
122
182
|
|
189
281
|
1.662
2.47
|
2.002
2.98
|
1.9
4.83
|
20
20
|
24
24
|
408641 |
12
12
|
7.0
7.0
|
7
7
|
|
|
20
0.51
|
|
|
|
45
1.14
|
0.477
1.21
|
142
211
|
|
237
353
|
1.662
2.47
|
2.002
2.98
|
1.9
4.83
|
17
17
|
21
21
|
408757 |
12
12
|
9.0
9.0
|
7
7
|
|
|
20
0.51
|
|
|
|
60
1.52
|
0.580
1.47
|
183
272
|
|
332
494
|
1.662
2.47
|
2.002
2.98
|
2.3
5.84
|
17
17
|
21
21
|
408815 |
12
12
|
12.0
12.0
|
7
7
|
|
|
20
0.51
|
|
|
|
60
1.52
|
0.657
1.67
|
244
363
|
|
425
632
|
1.662
2.47
|
2.002
2.98
|
2.6
6.60
|
12
12
|
15
15
|
412882 |
12
12
|
15.0
15.0
|
7
7
|
|
|
20
0.51
|
|
|
|
60
1.52
|
0.734
1.86
|
305
454
|
|
454
676
|
1.662
2.47
|
2.002
2.98
|
2.9
7.37
|
12
12
|
15
15
|
412916 |
12
12
|
19.0
19.0
|
7
7
|
|
|
20
0.51
|
|
|
|
60
1.52
|
0.772
1.96
|
388
577
|
|
562
836
|
1.662
2.47
|
2.002
2.98
|
3.1
7.87
|
12
12
|
15
15
|
552166 |
12
12
|
25.0
25.0
|
7
7
|
|
|
20
0.51
|
|
|
|
80
2.03
|
0.943
2.40
|
509
757
|
|
761
1132
|
1.662
2.47
|
2.002
2.98
|
3.8
9.65
|
11
11
|
13
13
|
552224 |
12
12
|
37.0
37.0
|
7
7
|
|
|
20
0.51
|
|
|
|
80
2.03
|
1.064
2.70
|
755
1124
|
|
1084
1613
|
1.662
2.47
|
2.002
2.98
|
5.3
13.46
|
10
10
|
12
12
|
408492 |
10
10
|
2.0
2.0
|
7
7
|
|
|
25
0.64
|
|
|
|
45
1.14
|
0.420
1.07
|
64
95
|
|
115
171
|
1.04
1.55
|
1.253
1.86
|
1.7
4.32
|
35
35
|
40
40
|
408534 |
10
10
|
3.0
3.0
|
7
7
|
|
|
25
0.64
|
|
|
|
45
1.14
|
0.446
1.13
|
97
144
|
|
159
237
|
1.04
1.55
|
1.253
1.86
|
1.8
4.57
|
35
35
|
40
40
|
408567 |
10
10
|
4.0
4.0
|
7
7
|
|
|
25
0.64
|
|
|
|
45
1.14
|
0.505
1.28
|
129
192
|
|
207
308
|
1.04
1.55
|
1.253
1.86
|
2.0
5.08
|
28
28
|
32
32
|
408591 |
10
10
|
5.0
5.0
|
7
7
|
|
|
25
0.64
|
|
|
|
45
1.14
|
0.565
1.44
|
161
240
|
|
258
384
|
1.04
1.55
|
1.253
1.86
|
2.3
5.84
|
28
28
|
32
32
|
408658 |
10
10
|
7.0
7.0
|
7
7
|
|
|
25
0.64
|
|
|
|
60
1.52
|
0.615
1.56
|
226
336
|
|
381
567
|
1.04
1.55
|
1.253
1.86
|
2.5
6.35
|
24
24
|
28
28
|
408765 |
10
10
|
9.0
9.0
|
7
7
|
|
|
25
0.64
|
|
|
|
60
1.52
|
0.715
1.82
|
291
433
|
|
501
746
|
1.04
1.55
|
1.253
1.86
|
2.9
7.37
|
24
24
|
28
28
|
408823 |
10
10
|
12.0
12.0
|
7
7
|
|
|
25
0.64
|
|
|
|
60
1.52
|
0.806
2.05
|
388
577
|
|
652
970
|
1.04
1.55
|
1.253
1.86
|
3.2
8.13
|
17
17
|
20
20
|
601666 |
10
10
|
19.0
19.0
|
7
7
|
|
|
25
0.64
|
|
|
|
80
2.03
|
0.993
2.52
|
613
912
|
|
903
1344
|
1.04
1.55
|
1.253
1.86
|
4.0
10.16
|
17
17
|
20
20
|