Southwire’s 600 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. VW-1 Rated #14 - #10 AWG. Sunlight Resistant - For Direct Burial - Silicone Free
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Color | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Min. Bend Radius (in) (cm) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
591931 |
16
16
|
2.0
2.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.332
0.84
|
16
24
|
|
52
77
|
4.181
6.22
|
5.037
7.50
|
1.3
3.30
|
-
-
|
18
18
|
591932 |
16
16
|
3.0
3.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.351
0.89
|
24
36
|
|
66
98
|
4.181
6.22
|
5.037
7.50
|
1.4
3.56
|
-
-
|
18
18
|
591933 |
16
16
|
4.0
4.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.382
0.97
|
32
48
|
|
82
122
|
4.181
6.22
|
5.037
7.50
|
1.5
3.81
|
-
-
|
14
14
|
591934 |
16
16
|
5.0
5.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.415
1.05
|
40
60
|
|
100
149
|
4.181
6.22
|
5.037
7.50
|
1.7
4.32
|
-
-
|
14
14
|
591935 |
16
16
|
7.0
7.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.451
1.15
|
56
83
|
|
128
190
|
4.181
6.22
|
5.037
7.50
|
1.8
4.57
|
-
-
|
12
12
|
591936 |
16
16
|
9.0
9.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.555
1.41
|
72
107
|
|
178
265
|
4.181
6.22
|
5.037
7.50
|
2.2
5.59
|
-
-
|
12
12
|
591937 |
16
16
|
12.0
12.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.618
1.57
|
96
143
|
|
225
335
|
4.181
6.22
|
5.037
7.50
|
2.5
6.35
|
-
-
|
9
9
|
591944 |
14
14
|
2.0
2.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.366
0.93
|
25
37
|
|
65
97
|
2.631
3.92
|
3.17
4.72
|
1.5
3.81
|
20
20
|
25
25
|
591947 |
14
14
|
3.0
3.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.388
0.99
|
37
55
|
|
86
128
|
2.631
3.92
|
3.17
4.72
|
1.6
4.06
|
20
20
|
25
25
|
591948 |
14
14
|
4.0
4.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.423
1.07
|
50
74
|
|
107
159
|
2.631
3.92
|
3.17
4.72
|
1.7
4.32
|
16
16
|
20
20
|
591949 |
14
14
|
5.0
5.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.461
1.17
|
62
92
|
|
129
192
|
2.631
3.92
|
3.17
4.72
|
1.8
4.57
|
16
16
|
20
20
|
591950 |
14
14
|
7.0
7.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.502
1.28
|
87
129
|
|
170
253
|
2.631
3.92
|
3.17
4.72
|
2.0
5.08
|
14
14
|
17
17
|
591951 |
14
14
|
9.0
9.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.616
1.56
|
112
167
|
|
232
345
|
2.631
3.92
|
3.17
4.72
|
2.5
6.35
|
14
14
|
17
17
|
591952 |
14
14
|
12.0
12.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.692
1.76
|
150
223
|
|
299
445
|
2.631
3.92
|
3.17
4.72
|
2.8
7.11
|
10
10
|
12
12
|
591953 |
14
14
|
15.0
15.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.560
1.42
|
187
278
|
|
413
615
|
2.631
3.92
|
3.17
4.72
|
2.2
5.59
|
10
10
|
12
12
|
591954 |
14
14
|
19.0
19.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.560
1.42
|
237
353
|
|
413
615
|
2.631
3.92
|
3.17
4.72
|
2.2
5.59
|
10
10
|
12
12
|
591959 |
12
12
|
2.0
2.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.404
1.03
|
40
60
|
|
86
128
|
1.662
2.47
|
2.002
2.98
|
1.6
4.06
|
25
25
|
30
30
|
591960 |
12
12
|
3.0
3.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.466
1.18
|
61
91
|
|
116
173
|
1.662
2.47
|
2.002
2.98
|
1.9
4.83
|
25
25
|
30
30
|
591962 |
12
12
|
4.0
4.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.469
1.19
|
81
121
|
|
147
219
|
1.662
2.47
|
2.002
2.98
|
1.9
4.83
|
20
20
|
24
24
|
591963 |
12
12
|
5.0
5.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.543
1.38
|
101
150
|
|
198
295
|
1.662
2.47
|
2.002
2.98
|
2.2
5.59
|
20
20
|
24
24
|
591964 |
12
12
|
7.0
7.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.589
1.50
|
142
211
|
|
253
377
|
1.662
2.47
|
2.002
2.98
|
2.4
6.10
|
17
17
|
21
21
|
591965 |
12
12
|
9.0
9.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.589
1.50
|
183
272
|
|
307
457
|
1.662
2.47
|
2.002
2.98
|
2.4
6.10
|
17
17
|
21
21
|
591966 |
12
12
|
12.0
12.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.466
1.18
|
244
363
|
|
411
612
|
1.662
2.47
|
2.002
2.98
|
1.9
4.83
|
12
12
|
15
15
|
591968 |
12
12
|
19.0
19.0
|
7
7
|
|
|
30
0.76
|
|
|
|
80
2.03
|
0.934
2.37
|
386
574
|
|
659
981
|
1.662
2.47
|
2.002
2.98
|
3.7
9.40
|
12
12
|
15
15
|
591973 |
10
10
|
2.0
2.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.448
1.14
|
64
95
|
|
116
173
|
1.04
1.55
|
1.253
1.86
|
1.8
4.57
|
35
35
|
40
40
|
591974 |
10
10
|
3.0
3.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.476
1.21
|
97
144
|
|
160
238
|
1.04
1.55
|
1.253
1.86
|
1.9
4.83
|
35
35
|
40
40
|
591976 |
10
10
|
4.0
4.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.560
1.42
|
129
192
|
|
225
335
|
1.04
1.55
|
1.253
1.86
|
2.2
5.59
|
28
28
|
32
32
|
591977 |
10
10
|
5.0
5.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.602
1.53
|
161
240
|
|
267
397
|
1.04
1.55
|
1.253
1.86
|
2.4
6.10
|
28
28
|
32
32
|
591978 |
10
10
|
7.0
7.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.655
1.66
|
226
336
|
|
355
528
|
1.04
1.55
|
1.253
1.86
|
2.6
6.60
|
24
24
|
28
28
|
591979 |
10
10
|
9.0
9.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.765
1.94
|
291
433
|
|
450
670
|
1.04
1.55
|
1.253
1.86
|
3.1
7.87
|
24
24
|
28
28
|
591980 |
10
10
|
12.0
12.0
|
7
7
|
|
|
30
0.76
|
|
|
|
80
2.03
|
0.899
2.28
|
388
577
|
|
619
921
|
1.04
1.55
|
1.253
1.86
|
3.6
9.14
|
17
17
|
20
20
|
591938 |
16
16
|
15.0
15.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.684
1.74
|
120
179
|
|
273
406
|
4.181
6.22
|
5.037
7.50
|
2.7
6.86
|
-
-
|
9
9
|