Southwire’s 2000 Volt power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Drain Wire | Diameter Over Shield (in) (cm) | Inner Jacket Thickness (mils) (mm) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | |
597958 |
12
12
|
0.0
0.0
|
19
19
|
0.088
0.22
|
75
1.91
|
|
|
|
|
|
|
|
0.243
0.62
|
20
30
|
|
39
58
|
579962 |
10
10
|
1.0
1.0
|
19
19
|
0.113
0.29
|
75
1.91
|
|
|
|
|
|
|
75
1.91
|
0.263
0.67
|
32
48
|
|
53
79
|
569037 |
8
8
|
1.0
1.0
|
19
19
|
0.141
0.36
|
85
2.16
|
|
|
|
|
|
|
|
0.313
0.80
|
50
74
|
|
79
118
|
569039 |
6
6
|
1.0
1.0
|
19
19
|
0.177
0.45
|
85
2.16
|
|
|
|
|
|
|
85
2.16
|
0.349
0.89
|
81
121
|
|
114
170
|
569040 |
4
4
|
1.0
1.0
|
19
19
|
0.225
0.57
|
85
2.16
|
|
|
|
|
|
|
|
0.396
1.01
|
128
190
|
|
168
250
|
569043 |
1/0
1/0
|
1.0
1.0
|
19
19
|
0.361
0.92
|
105
2.67
|
|
|
|
|
|
|
|
0.570
1.45
|
326
485
|
|
396
589
|
569044 |
2/0
2/0
|
1.0
1.0
|
19
19
|
0.405
1.03
|
105
2.67
|
|
|
|
|
|
|
|
0.614
1.56
|
410
610
|
|
488
726
|
578324 |
500
500
|
1.0
1.0
|
37
37
|
0.789
2.00
|
120
3.05
|
|
|
|
|
|
|
|
1.006
2.56
|
1543
2296
|
|
1685
2508
|
Cond. Size (AWG/Kcmil) | Conductor Number | Min. Bend Radius (in) (cm) | Max Pull Tension (lbs) (kg) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Capacitive Reactance (Mohms x 1000ft) (Mohms x km) | Inductive Reactance (ohms/1000') (ohms/km) | Shield Short Circuit Current 6 Cycles (amps) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
597958 |
12
12
|
0.0
0.0
|
1.0
2.54
|
|
1.662
2.47
|
2.002
2.98
|
|
0.054
0.08
|
|
25
25
|
30
30
|
579962 |
10
10
|
1.0
1.0
|
1.1
2.79
|
|
1.04
1.55
|
1.253
1.86
|
|
0.05
0.07
|
|
35
35
|
40
40
|
569037 |
8
8
|
1.0
1.0
|
1.3
3.30
|
132
59.87
|
0.653
0.97
|
0.786
1.17
|
|
0.052
0.08
|
|
50
50
|
55
55
|
569039 |
6
6
|
1.0
1.0
|
1.4
3.56
|
209
94.80
|
0.411
0.61
|
0.495
0.74
|
|
0.051
0.08
|
|
65
65
|
75
75
|
569040 |
4
4
|
1.0
1.0
|
1.6
4.06
|
333
151.05
|
0.258
0.38
|
0.31
0.46
|
|
0.048
0.07
|
|
85
85
|
95
95
|
569043 |
1/0
1/0
|
1.0
1.0
|
2.3
5.84
|
844
382.83
|
0.102
0.15
|
0.122
0.18
|
|
0.044
0.07
|
|
150
150
|
170
170
|
569044 |
2/0
2/0
|
1.0
1.0
|
2.5
6.35
|
1064
482.62
|
0.081
0.12
|
0.097
0.14
|
|
0.043
0.06
|
|
175
175
|
195
195
|
578324 |
500
500
|
1.0
1.0
|
5.0
12.70
|
4000
1814.37
|
0.022
0.03
|
0.029
0.04
|
|
0.039
0.06
|
|
380
380
|
430