Applications and Features: Power supply cable for VFDs and motors, suitable for cable tray, conduit, raceways, (TC-ER) and machine tool wiring conforming to NFPA 79. Suitable for free air and direct burial. Its flexible design is ideal for use on operation processes in accordance with NEC® Articles 336, 501 and 502 including, but not limited to: fans, pumps, conveyors, compressors, elevators and lifts, extruders, crushers and presses, assembly lines, food and beverage, wind energy and data centers. Cable is rated for -40C Cold Bend and Impact. Multiple approvals for multiple applications. The additional shielded pair can be used for signal, temperature sensors or brake.
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Drain Wire | Diameter Over Shield (in) (cm) | Inner Jacket Thickness (mils) (mm) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | |
646241 |
16
16
|
3.0
3.0
|
26
26
|
0.059
0.15
|
45
1.14
|
|
|
1x16
1x16
|
0.480
1.22
|
|
|
62
1.57
|
0.604
1.53
|
92
137
|
|
199
296
|
646242 |
14
14
|
3.0
3.0
|
41
41
|
0.073
0.19
|
45
1.14
|
|
|
1x14
1x14
|
0.565
1.44
|
|
|
62
1.57
|
0.689
1.75
|
128
190
|
|
242
360
|
646243 |
12
12
|
3.0
3.0
|
65
65
|
0.094
0.24
|
45
1.14
|
|
|
1x12
1x12
|
0.595
1.51
|
|
|
62
1.57
|
0.719
1.83
|
169
251
|
|
308
458
|
646244 |
10
10
|
3.0
3.0
|
105
105
|
0.117
0.30
|
45
1.14
|
|
|
1x10
1x10
|
0.649
1.65
|
|
|
62
1.57
|
0.773
1.96
|
233
347
|
|
370
551
|
677156 |
8
8
|
3.0
3.0
|
168
168
|
0.153
0.39
|
60
1.52
|
|
|
4x14
4x14
|
0.870
2.21
|
|
|
82
2.08
|
1.034
2.63
|
367
546
|
|
654
973
|
677158 |
6
6
|
3.0
3.0
|
266
266
|
0.198
0.50
|
60
1.52
|
|
|
4x12
4x12
|
0.935
2.37
|
|
|
82
2.08
|
1.099
2.79
|
519
772
|
|
829
1234
|
Cond. Size (AWG/Kcmil) | Conductor Number | Min. Bend Radius (in) (cm) | Max Pull Tension (lbs) (kg) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Capacitive Reactance (Mohms x 1000ft) (Mohms x km) | Inductive Reactance (ohms/1000') (ohms/km) | Shield Short Circuit Current 6 Cycles (amps) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
646241 |
16
16
|
3.0
3.0
|
7.2
18.29
|
61
27.67
|
4.487
6.68
|
5.406
8.05
|
0.065
0.10
|
0.033
0.05
|
|
-
-
|
18
18
|
646242 |
14
14
|
3.0
3.0
|
8.3
21.08
|
98
44.45
|
2.814
4.19
|
3.391
5.05
|
0.057
0.08
|
0.058
0.09
|
|
20
20
|
25
25
|
646243 |
12
12
|
3.0
3.0
|
8.6
21.84
|
156
70.76
|
1.774
2.64
|
2.137
3.18
|
0.047
0.07
|
0.054
0.08
|
|
25
25
|
30
30
|
646244 |
10
10
|
3.0
3.0
|
9.3
23.62
|
249
112.94
|
1.111
1.65
|
1.339
1.99
|
0.04
0.06
|
0.05
0.07
|
|
35
35
|
40
40
|
677156 |
8
8
|
3.0
3.0
|
12.4
31.50
|
396
179.62
|
0.715
1.06
|
0.861
1.28
|
0.04
0.06
|
0.052
0.08
|
|
50
50
|
55
55
|
677158 |
6
6
|
3.0
3.0
|
13.2
33.53
|
629
285.31
|
0.45
0.67
|
0.541
0.81
|
0.033
0.05
|
0.051
0.08
|
|
65
65
|
75
75
|