For use in residential, farm and industrial water well applications. Used in both Grounded and ungrounded water well cable systems. Conductors are parallel and insulated with PVC colored black, red, and yellow. Insulated and jacketed with a premium thermoplastic elastomer (TPE) material. Oil resistant. Used in both high temperature and low temperature wells
Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Insulation Thickness (mils) (mm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | |
More Options |
14 AWG
14 AWG
|
3
3
|
41
41
|
0.073
0.19
|
30
0.76
|
25
0.64
|
0.188 x 0.464
0.48 x 1.18
|
37
55
|
65
97
|
More Options |
14 AWG
14 AWG
|
4
4
|
41
41
|
0.073
0.19
|
30
0.76
|
25
0.64
|
0.188 x 0.602
0.48 x 1.53
|
50
74
|
87
129
|
More Options |
12 AWG
12 AWG
|
3
3
|
65
65
|
0.094
0.24
|
30
0.76
|
25
0.64
|
0.206 x 0.518
0.52 x 1.32
|
60
89
|
94
140
|
More Options |
12 AWG
12 AWG
|
4
4
|
65
65
|
0.094
0.24
|
30
0.76
|
25
0.64
|
0.206 x 0.674
0.52 x 1.71
|
80
119
|
126
188
|
More Options |
10 AWG
10 AWG
|
3
3
|
105
105
|
0.117
0.30
|
30
0.76
|
25
0.64
|
0.231 x 0.593
0.59 x 1.51
|
96
143
|
136
202
|
More Options |
10 AWG
10 AWG
|
4
4
|
105
105
|
0.117
0.30
|
30
0.76
|
25
0.64
|
0.231 x 0.774
0.59 x 1.97
|
128
190
|
181
269
|
More Options |
8 AWG
8 AWG
|
4
4
|
168
168
|
0.153
0.39
|
45
1.14
|
30
0.76
|
0.316 x 1.010
0.80 x 2.57
|
188
280
|
289
430
|
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
Cond. Size | Conductor Number | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | Max Pull Tension (lbs) (kg) | Min. Bend Radius (in) (cm) | Allowable Ampacity Raceway 75C | Allowable Ampacity Raceway 90C |
14 AWG
14 AWG
|
3
3
|
2.814
4.19
|
3.391
5.05
|
0.058
0.09
|
98
44.45
|
1.9
4.83
|
20
20
|
25
25
|
14 AWG
14 AWG
|
4
4
|
2.814
4.19
|
3.391
5.05
|
0.058
0.09
|
105
47.63
|
2.4
6.10
|
16
16
|
20
20
|
12 AWG
12 AWG
|
3
3
|
1.774
2.64
|
2.137
3.18
|
0.054
0.08
|
156
70.76
|
2.1
5.33
|
25
25
|
30
30
|
12 AWG
12 AWG
|
4
4
|
1.774
2.64
|
2.137
3.18
|
0.054
0.08
|
167
75.75
|
2.7
6.86
|
20
20
|
24
24
|
10 AWG
10 AWG
|
3
3
|
1.111
1.65
|
1.339
1.99
|
0.050
0.07
|
249
112.94
|
2.4
6.10
|
35
35
|
40
40
|
10 AWG
10 AWG
|
4
4
|
1.111
1.65
|
1.339
1.99
|
0.050
0.07
|
265
120.20
|
3.1
7.87
|
28
28
|
32
32
|
8 AWG
8 AWG
|
4
4
|
0.715
1.06
|
0.861
1.28
|
0.052
0.08
|
422
191.42
|
5.0
12.70
|
40
40
|
44
44
|
* Inductive impedance is based on non-ferrous conduit with one diameter spacing.