SPEC: 10115

Landscape Low-Voltage 150 Volt Lighting

-20°C to +60°C, 150 Volts Rated, UL ULEC and CSA LVLL

Download Category Specifications
PDF Excel Table

Application & Features

  • Outdoor Low-Voltage Underground Landscape Lighting Cable is designed for landscape, security, and outdoor accent lighting applications not to exceed 150 volts.

  • Landscape Lighting Cable is Sunlight Resistant sutable for Direct Burial Stranded Copper Conductor Black PVC Insulation/Jacket.
  • Specifications

    Select a set of products below for more information:
    Cond. Size Conductor Number Cond. Strands Diameter Over Conductor (in) (cm) Color Approx. OD (in) (cm) Copper Weight (lbs/1000') (kgs/km) Approx. Weight (lbs/1000') (kgs/km)
    More Options
    16 AWG 16 AWG
    2 2
    26 26
    0.059 0.15
    Black Black
    0.305 0.77
    16 24
    37 55
    More Options
    14 AWG 14 AWG
    2 2
    41 41
    0.073 0.19
    Black Black
    0.341 0.87
    25 37
    45 67
    More Options
    12 AWG 12 AWG
    2 2
    65 65
    0.094 0.24
    Black Black
    0.357 0.91
    40 60
    66 98
    More Options
    10 AWG 10 AWG
    2 2
    104 104
    0.117 0.30
    Black Black
    0.443 1.13
    64 95
    94 140

    TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

    Cond. Size Conductor Number DC Resistance at 25C (ohms/1000') (ohms/km) AC Resistance at 75C (ohms/1000') (ohms/km) Inductive Reactance (ohms/1000') (ohms/km) Max Pull Tension (lbs) (kg) Min. Bend Radius (in) (cm) Allowable Ampacity Raceway 75C Allowable Ampacity Raceway 90C
    16 AWG 16 AWG
    2 2
    4.487 6.68
    5.406 8.05
    0.033 0.05
    1.2 3.05
    - -
    18 18
    14 AWG 14 AWG
    2 2
    2.814 4.19
    3.391 5.05
    0.058 0.09
    65 29.48
    1.4 3.56
    20 20
    25 25
    12 AWG 12 AWG
    2 2
    1.774 2.64
    2.137 3.18
    0.054 0.08
    104 47.17
    1.4 3.56
    25 25
    30 30
    10 AWG 10 AWG
    2 2
    1.111 1.65
    1.339 1.99
    0.050 0.07
    166 75.30
    1.8 4.57
    35 35
    40 40

    * Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections 310.15 and 110.14(C) for additional requirements.

    Standards & References

    • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
    • RoHS-2 (European Directive 2011/65/EU)

    Construction

    1. Conductor:Class K, flexible stranded bare copper per ASTM B172
    2. Overall Insulation/Jacket:Polyvinyl Chloride (PVC)

    Resources

    There are no downloadable resources for this product.