Southwire’s 600 or 1000 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. The jacket acts as gas/vapor-tight polymeric sheath that is extruded over the core per Sections 501.15(D) and 501.15(E) of the NEC, however when these cables are used in a hazardous location, they may need to be sealed further as described in more detail in the NEC. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. VW-1 Rated\ - Sunlight Resistant - For Direct Burial - Silicone Free.
Cond. Size (AWG/Kcmil) | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Color | Insulation Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground (No. x AWG) | Diameter Over Armor (in) (cm) | Jacket Thickness (mils) (mm) | Approx. OD (in) (cm) | Copper Weight (lbs/1000') (kgs/km) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | DC Resistance @ 25C (ohms/1000') (ohms/km) | AC Resistance @ 75C (ohms/1000') (ohms/km) | Min. Bend Radius (in) (cm) | Raceway Ampacity @ 75C (amps) | Raceway Ampacity @ 90C (amps) | |
952459 |
14
14
|
2.0
2.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.355
0.90
|
25
37
|
|
66
98
|
2.631
3.92
|
3.17
4.72
|
1.4
3.56
|
20
20
|
25
25
|
952465 |
14
14
|
3.0
3.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.376
0.96
|
38
57
|
|
90
134
|
2.631
3.92
|
3.17
4.72
|
1.5
3.81
|
20
20
|
25
25
|
952473 |
14
14
|
4.0
4.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.409
1.04
|
51
76
|
|
109
162
|
2.631
3.92
|
3.17
4.72
|
1.6
4.06
|
16
16
|
20
20
|
952481 |
14
14
|
5.0
5.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.447
1.14
|
64
95
|
|
129
192
|
2.631
3.92
|
3.17
4.72
|
1.8
4.57
|
16
16
|
20
20
|
952499 |
14
14
|
6.0
6.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.486
1.23
|
76
113
|
|
151
225
|
2.631
3.92
|
3.17
4.72
|
1.9
4.83
|
16
16
|
20
20
|
952440 |
14
14
|
7.0
7.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.482
1.22
|
89
132
|
|
168
250
|
2.631
3.92
|
3.17
4.72
|
1.9
4.83
|
14
14
|
17
17
|
952507 |
14
14
|
8.0
8.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.559
1.42
|
102
152
|
|
208
310
|
2.631
3.92
|
3.17
4.72
|
2.2
5.59
|
14
14
|
17
17
|
952572 |
14
14
|
9.0
9.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.598
1.52
|
114
170
|
|
231
344
|
2.631
3.92
|
3.17
4.72
|
2.4
6.10
|
14
14
|
17
17
|
952598 |
14
14
|
12.0
12.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.670
1.70
|
153
228
|
|
295
439
|
2.631
3.92
|
3.17
4.72
|
2.7
6.86
|
10
10
|
12
12
|
952606 |
14
14
|
15.0
15.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.742
1.88
|
191
284
|
|
358
533
|
2.631
3.92
|
3.17
4.72
|
3.0
7.62
|
10
10
|
12
12
|
952614 |
14
14
|
19.0
19.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.780
1.98
|
242
360
|
|
439
653
|
2.631
3.92
|
3.17
4.72
|
3.1
7.87
|
10
10
|
12
12
|
952630 |
14
14
|
25.0
25.0
|
7
7
|
|
|
30
0.76
|
|
|
|
80
2.03
|
0.952
2.42
|
319
475
|
|
602
896
|
2.631
3.92
|
3.17
4.72
|
3.8
9.65
|
9
9
|
11
11
|
952648 |
14
14
|
30.0
30.0
|
7
7
|
|
|
30
0.76
|
|
|
|
80
2.03
|
1.006
2.56
|
386
574
|
|
707
1052
|
2.631
3.92
|
3.17
4.72
|
5.0
12.70
|
9
9
|
11
11
|
952655 |
14
14
|
37.0
37.0
|
7
7
|
|
|
30
0.76
|
|
|
|
80
2.03
|
1.083
2.75
|
474
705
|
|
849
1263
|
2.631
3.92
|
3.17
4.72
|
5.4
13.72
|
8
8
|
10
10
|
953042 |
12
12
|
2.0
2.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.388
0.99
|
40
60
|
|
88
131
|
1.662
2.47
|
2.002
2.98
|
1.6
4.06
|
25
25
|
30
30
|
953059 |
12
12
|
3.0
3.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.408
1.04
|
61
91
|
|
117
174
|
1.662
2.47
|
2.002
2.98
|
1.6
4.06
|
25
25
|
30
30
|
953067 |
12
12
|
4.0
4.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.449
1.14
|
81
121
|
|
152
226
|
1.662
2.47
|
2.002
2.98
|
1.8
4.57
|
20
20
|
24
24
|
953075 |
12
12
|
5.0
5.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.487
1.24
|
101
150
|
|
174
259
|
1.662
2.47
|
2.002
2.98
|
1.9
4.83
|
20
20
|
24
24
|
953091 |
12
12
|
7.0
7.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.561
1.42
|
142
211
|
|
248
369
|
1.662
2.47
|
2.002
2.98
|
2.2
5.59
|
17
17
|
21
21
|
953117 |
12
12
|
9.0
9.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.657
1.67
|
182
271
|
|
315
469
|
1.662
2.47
|
2.002
2.98
|
2.6
6.60
|
17
17
|
21
21
|
953125 |
12
12
|
10.0
10.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.714
1.81
|
202
301
|
|
349
519
|
1.662
2.47
|
2.002
2.98
|
2.9
7.37
|
12
12
|
15
15
|
953133 |
12
12
|
12.0
12.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.738
1.87
|
243
362
|
|
404
601
|
1.662
2.47
|
2.002
2.98
|
3.0
7.62
|
12
12
|
15
15
|
953141 |
12
12
|
15.0
15.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.819
2.08
|
303
451
|
|
496
738
|
1.662
2.47
|
2.002
2.98
|
3.3
8.38
|
12
12
|
15
15
|
953158 |
12
12
|
19.0
19.0
|
7
7
|
|
|
30
0.76
|
|
|
|
80
2.03
|
0.904
2.30
|
385
573
|
|
647
963
|
1.662
2.47
|
2.002
2.98
|
3.6
9.14
|
12
12
|
15
15
|
953174 |
12
12
|
25.0
25.0
|
7
7
|
|
|
30
0.76
|
|
|
|
80
2.03
|
1.051
2.67
|
511
760
|
|
835
1243
|
1.662
2.47
|
2.002
2.98
|
5.3
13.46
|
11
11
|
13
13
|
953190 |
12
12
|
37.0
37.0
|
7
7
|
|
|
30
0.76
|
|
|
|
80
2.03
|
1.198
3.04
|
753
1121
|
|
1181
1758
|
1.662
2.47
|
2.002
2.98
|
6.0
15.24
|
10
10
|
12
12
|
952861 |
10
10
|
2.0
2.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.448
1.14
|
64
95
|
|
121
180
|
1.04
1.55
|
1.253
1.86
|
1.8
4.57
|
35
35
|
40
40
|
952879 |
10
10
|
3.0
3.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.472
1.20
|
97
144
|
|
166
247
|
1.04
1.55
|
1.253
1.86
|
1.9
4.83
|
35
35
|
40
40
|
952895 |
10
10
|
4.0
4.0
|
7
7
|
|
|
30
0.76
|
|
|
|
45
1.14
|
0.547
1.39
|
129
192
|
|
229
341
|
1.04
1.55
|
1.253
1.86
|
2.2
5.59
|
28
28
|
32
32
|
952887 |
10
10
|
5.0
5.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.603
1.53
|
161
240
|
|
273
406
|
1.04
1.55
|
1.253
1.86
|
2.4
6.10
|
28
28
|
32
32
|
952911 |
10
10
|
7.0
7.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.657
1.67
|
226
336
|
|
361
537
|
1.04
1.55
|
1.253
1.86
|
2.6
6.60
|
24
24
|
28
28
|
952929 |
10
10
|
8.0
8.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.711
1.81
|
257
382
|
|
408
607
|
1.04
1.55
|
1.253
1.86
|
2.8
7.11
|
24
24
|
28
28
|
952937 |
10
10
|
9.0
9.0
|
7
7
|
|
|
30
0.76
|
|
|
|
60
1.52
|
0.765
1.94
|
289
430
|
|
455
677
|
1.04
1.55
|
1.253
1.86
|
3.1
7.87
|
24
24
|
28
28
|
952952 |
10
10
|
12.0
12.0
|
7
7
|
|
|
30
0.76
|
|
|
|
80
2.03
|
0.904
2.30
|
386
574
|
|
625
930
|
1.04
1.55
|
1.253
1.86
|
3.6
9.14
|
17
17
|
20
20
|
952960 |
10
10
|
15.0
15.0
|
7
7
|
|
|
30
0.76
|
|
|
|
80
2.03
|
1.001
2.54
|
483
719
|
|
764
1137
|
1.04
1.55
|
1.253
1.86
|
5.0
12.70
|
17
17
|
20
20
|
952978 |
10
10
|
19.0
19.0
|
7
7
|
|
|
30
0.76
|
|
|
|
80
2.03
|
1.045
2.65
|
613
912
|
|
932
1387
|
1.04
1.55
|
1.253
1.86
|
5.2
13.21
|
17
17
|
20
20
|