Southwire's Romex® SIMpull ® NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations. The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C for two-conductor cables and -10°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code1 for further information related to applications.
Conductor | Ground Wire | |||||||||
Size (AWG or kcmil) (mm2) | No. of Conductors | No. of Strands | Size (AWG) | Jacket Thickness (mils) (mm) | Nom. OD (mils) (mm) | Nom. Height (mils) (mm) | Nom. Width (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | Allowable Ampacity at 30°C Ambient | |
More Options |
14 AWG
14 AWG
|
2
2
|
1
1
|
14
14
|
30
0.76
|
|
196
4.98
|
396
10.07
|
69
103
|
25*
25*
|
More Options |
14 AWG
14 AWG
|
3
3
|
1
1
|
14
14
|
30
0.76
|
388
9.87
|
|
|
91
135
|
25*
25*
|
More Options |
12 AWG
12 AWG
|
2
2
|
1
1
|
14
14
|
30
0.76
|
|
212
5.41
|
429
10.91
|
88
131
|
30*
30*
|
More Options |
12 AWG
12 AWG
|
3
3
|
1
1
|
14
14
|
30
0.76
|
428
10.89
|
|
|
118
176
|
30*
30*
|
More Options |
10 AWG
10 AWG
|
2
2
|
1
1
|
12
12
|
30
0.76
|
|
233
5.94
|
488
12.41
|
124
185
|
40*
40*
|
More Options |
10 AWG
10 AWG
|
3
3
|
1
1
|
12
12
|
30
0.76
|
479
12.19
|
|
|
168
250
|
40*
40*
|
More Options |
8 AWG
8 AWG
|
2
2
|
7
7
|
10
10
|
45
1.14
|
|
316
8.03
|
694
17.63
|
211
314
|
55
55
|
More Options |
8 AWG
8 AWG
|
3
3
|
7
7
|
10
10
|
45
1.14
|
635
16.14
|
|
|
284
422
|
55
55
|
More Options |
6 AWG
6 AWG
|
2
2
|
7
7
|
8
8
|
45
1.14
|
|
374
9.50
|
800
20.32
|
340
506
|
75
75
|
More Options |
6 AWG
6 AWG
|
3
3
|
7
7
|
8
8
|
45
1.14
|
775
19.70
|
|
|
433
645
|
75
75
|
More Options |
4 AWG
4 AWG
|
2
2
|
7
7
|
8
8
|
60
1.52
|
839
21.32
|
|
|
463
689
|
|
More Options |
3 AWG
3 AWG
|
2
2
|
7
7
|
6
6
|
80
2.03
|
937
23.82
|
|
|
611
909
|
|
More Options |
3 AWG
3 AWG
|
3
3
|
7
7
|
6
6
|
80
2.03
|
1029
26.14
|
|
|
823
1225
|
115
115
|
* In accordance with the 2015 Canadian Electrical Code Part I Rule 14-104(2)
Romex® SIMpull ® NMD90 cables meet or exceed the following requirements: • ASTM • CSA C22.2 No. 48 (non-metallic sheathed cable) • Canadian Electrical Code
Southwire's Romex® SIMpull ® NMD90 cables are available as two- or three-conductor cables with a bare grounding conductor. It is manufactured using annealed (soft) copper conductors—compressed standing for stranded conductors; a heat-resistant thermoplastic polyvinyl chloride (PVC) insulation and nylon jacket for the individual conductors with a PVC jacket for the overall construction. Conductors are white" black and red (for 3 conductor cables). Cable jackets are colour coded by size for quick identification: