SPEC: 10020

RHH/RHW/USE-2 Aluminum with AlumaFlex® Brand Conductors Silicone-Free

600 Volts. Underground Service Entrance Cable. AlumaFlex® Brand Aluminum Alloy (AA-8176) Conductor. Cross-linked Polyethylene (XLP) Insulation. High Heat, Moisture, and Sunlight Resistant. Rated SIS in sizes 6 – 4/0 AWG.

Download Category Specifications
PDF Excel Table

Application & Features

Southwire’s 600 Volt power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs./FT maximum sidewall pressure.

Specifications

Select a set of products below for more information:
Cond. Size Conductor Number Cond. Strands Diameter Over Conductor (in) (cm) Inner Layer Thickness (mils) (mm) Approx. OD (in) (cm) Aluminum Weight (lbs/1000') (kgs/km) Approx. Weight (lbs/1000') (kgs/km)
More Options
6 AWG 6 AWG
0 0
7 7
0.169 0.43
60 1.52
0.295 0.75
24 36
46 68
More Options
4 AWG 4 AWG
1 1
7 7
0.212 0.54
60 1.52
0.339 0.86
39 58
65 97
More Options
2 AWG 2 AWG
1 1
6 6
0.268 0.68
60 1.52
0.394 1.00
62 92
93 138
More Options
1 AWG 1 AWG
1 1
8 8
0.298 0.76
80 2.03
0.467 1.19
78 116
126 188
More Options
1/0 AWG 1/0 AWG
1 1
10 10
0.336 0.85
80 2.03
0.504 1.28
99 147
151 225
More Options
2/0 AWG 2/0 AWG
1 1
12 12
0.376 0.96
80 2.03
0.544 1.38
125 186
182 271
More Options
3/0 AWG 3/0 AWG
1 1
15 15
0.422 1.07
80 2.03
0.591 1.50
158 235
221 329
More Options
4/0 AWG 4/0 AWG
1 1
19 19
0.474 1.20
80 2.03
0.643 1.63
199 296
269 400
More Options
250 KCMIL 250 KCMIL
1 1
22 22
0.520 1.32
95 2.41
0.720 1.83
235 350
321 478
More Options
300 KCMIL 300 KCMIL
1 1
35 35
0.569 1.45
95 2.41
0.770 1.96
282 420
381 567
More Options
350 KCMIL 350 KCMIL
1 1
35 35
0.615 1.56
95 2.41
0.816 2.07
329 490
435 647
More Options
400 KCMIL 400 KCMIL
1 1
35 35
0.659 1.67
95 2.41
0.859 2.18
376 560
490 729
More Options
500 KCMIL 500 KCMIL
1 1
34 34
0.735 1.87
95 2.41
0.938 2.38
471 701
601 894
More Options
600 KCMIL 600 KCMIL
1 1
58 58
0.812 2.06
110 2.79
1.037 2.63
565 841
723 1076
More Options
750 KCMIL 750 KCMIL
1 1
61 61
0.908 2.31
110 2.79
1.140 2.90
706 1051
884 1316

* Strand count meets minimum number per ASTM

Cond. Size Conductor Number Min. Bend Radius (in) (cm) Max Pull Tension (lbs) (kg) DC Resistance at 25C (ohms/1000') (ohms/km) AC Resistance at 75C (ohms/1000') (ohms/km) Inductive Reactance (ohms/1000') (ohms/km) Allowable Ampacity Raceway 75C Allowable Ampacity Raceway 90C
More Options
6 AWG 6 AWG
0 0
1.2 3.05
157 71.21
0.674 1.00
0.812 1.21
0.051 0.08
50 50
55 55
More Options
4 AWG 4 AWG
1 1
1.4 3.56
250 113.40
0.424 0.63
0.510 0.76
0.048 0.07
65 65
75 75
More Options
2 AWG 2 AWG
1 1
1.6 4.06
398 180.53
0.267 0.40
0.321 0.48
0.045 0.07
90 90
100 100
More Options
1 AWG 1 AWG
1 1
1.9 4.83
502 227.70
0.211 0.31
0.254 0.38
0.046 0.07
100 100
115 115
More Options
1/0 AWG 1/0 AWG
1 1
2.0 5.08
633 287.12
0.168 0.25
0.201 0.30
0.044 0.07
120 120
135 135
More Options
2/0 AWG 2/0 AWG
1 1
2.2 5.59
798 361.97
0.133 0.20
0.160 0.24
0.043 0.06
135 135
150 150
More Options
3/0 AWG 3/0 AWG
1 1
2.4 6.10
1006 456.31
0.105 0.16
0.126 0.19
0.042 0.06
155 155
175 175
More Options
4/0 AWG 4/0 AWG
1 1
2.6 6.60
1269 575.61
0.084 0.13
0.100 0.15
0.041 0.06
180 180
205 205
More Options
250 KCMIL 250 KCMIL
1 1
2.9 7.37
1500 680.39
0.071 0.11
0.086 0.13
0.041 0.06
205 205
230 230
More Options
300 KCMIL 300 KCMIL
1 1
3.1 7.87
1800 816.47
0.059 0.09
0.071 0.11
0.041 0.06
230 230
260 260
More Options
350 KCMIL 350 KCMIL
1 1
3.3 8.38
2100 952.54
0.050 0.07
0.062 0.09
0.040 0.06
250 250
280 280
More Options
400 KCMIL 400 KCMIL
1 1
3.4 8.64
2400 1088.62
0.044 0.07
0.054 0.08
0.040 0.06
270 270
305 305
More Options
500 KCMIL 500 KCMIL
1 1
3.8 9.65
3000 1360.78
0.035 0.05
0.044 0.07
0.039 0.06
310 310
350 350
More Options
600 KCMIL 600 KCMIL
1 1
5.2 13.21
3600 1632.93
0.029 0.04
0.037 0.06
0.039 0.06
340 340
385 385
More Options
750 KCMIL 750 KCMIL
1 1
5.7 14.48
4500 2041.16
0.024 0.04
0.031 0.05
0.038 0.06
385 385
435 435

† Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections 310.15 and 110.14(C) for additional requirements.
† Ampacities have been adjusted for more than Three Current-Carrying Conductors.
* Inductive Reactance is based on non-ferrous conduit with one diameter spacing center-to-center.

Size (Strand) Black White Brown Orange Yellow Green
6 (7) 6 (7)
272799
301572
4 (7) 4 (7)
272807
334680
2 (6) 2 (6)
272823 575240
1 (8) 1 (8)
272831
1/0 (10) 1/0 (10)
272849
2/0 (12) 2/0 (12)
272856
3/0 (15) 3/0 (15)
272864
4/0 (19) 4/0 (19)
272872
250 (22) 250 (22)
272880
300 (35) 300 (35)
272898
350 (35) 350 (35)
272906
138190 138191 138192
576086 576086
400 (35) 400 (35)
272914
500 (34) 500 (34)
272922
560674 560674
600 (58) 600 (58)
272930
138205 560671 138206
700 (58) 700 (58)
596530 596530
750 (61) 750 (61)
272955

Standards & References

  • ASTM B800 8000 Series Aluminum Alloy Wire
  • ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
  • ASTM B836 Compact Rounded Stranded Aluminum Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 854 Service Entrance Cable
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • RoHS-2 (European Directive 2011/65/EU)

Construction

  1. Conductor: Class B compact stranded bare aluminum per ASTM B800 and ASTM B801
  2. Insulation: Cross Linked Polyethylene (XLPE) Type RHH/RHW-2 USE-2 Silicone-Free