600V ROYAL® SOOW Power Cord Non-UL/CSA with Black Jacket 90°C

600V ROYAL® SOOW Power Cord Non-UL/CSA with Black Jacket 90°C

600 Volt, 90°C Flexible Cord. Heat, Moisture and Oil Resistant EPDM Rubber Insulation and Heat, Moisture and Oil Resistant Flexible CPE Jacket, Non UL / Non CSA.
Download Category Specifications:
PDF Excel Table

Application

Southwire Royal® Non UL/Non CSA SOOW cord is designed for use with industrial equipment, heavy tools, battery chargers, portable lights and power extensions, suitable for outdoor applications. The cable is rated -40°C to 90°C, sunlight, water, oil, and weather resistant. Southwire Type SOOW Flexible Cords are permitted for use as specified by Article 400 and related articles of the 2014 National Electrical Code

Specifications

measurement
imperial metric
Select a set of products below for more information:
Conductor
Size (AWG or kcmil) No. of Conductors No. of Strands Nom. OD (mils) (mm) Nominal Total Weight (lbs/1000') (kgs/km) Allowable Ampacity Nom. DC Resistance (Conductor) Conductor Colors
569972 8 AWG 8 AWG 2 2 133 133 615 15.62 218 325 40 40 0.72 0.72 BLACK/WHITE BLACK/WHITE
558088 8 AWG 8 AWG 3 3 133 133 645 16.38 284 422 40 40 0.72 0.72 BLACK/WHITE/GREEN BLACK/WHITE/GREEN
558093 8 AWG 8 AWG 4 4 133 133 711 18.06 377 561 35 35 0.72 0.72 BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
558105 8 AWG 8 AWG 5 5 133 133 834 21.18 492 732 28 28 0.72 0.72 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
569973 6 AWG 6 AWG 2 2 133 133 721 18.31 321 477 55 55 0.4 0.4 BLACK/WHITE BLACK/WHITE
558092 6 AWG 6 AWG 3 3 133 133 726 18.44 418 623 55 55 0.4 0.4 BLACK/WHITE/GREEN BLACK/WHITE/GREEN
558091 6 AWG 6 AWG 4 4 133 133 803 20.40 549 817 45 45 0.4 0.4 BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
558161 6 AWG 6 AWG 5 5 133 133 937 23.80 703 1045 36 36 0.4 0.4 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
558137 4 AWG 4 AWG 3 3 133 133 825 20.96 602 896 70 70 0.27 0.27 BLACK/WHITE/GREEN BLACK/WHITE/GREEN
558090 4 AWG 4 AWG 4 4 133 133 950 24.13 852 1268 60 60 0.27 0.27 BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
569975 4 AWG 4 AWG 5 5 133 133 1155 29.34 1163 1731 48 48 0.27 0.27 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE
558136 2 AWG 2 AWG 3 3 168 168 1090 27.69 994 1479 95 95 0.16 0.16 BLACK/WHITE/GREEN BLACK/WHITE/GREEN
558089 2 AWG 2 AWG 4 4 168 168 1290 32.77 1328 1976 80 80 0.16 0.16 BLACK/WHITE/RED/GREEN BLACK/WHITE/RED/GREEN
569976 2 AWG 2 AWG 5 5 168 168 1325 33.66 1615 2404 64 64 0.16 0.16 BLACK/WHITE/RED/GREEN/ORANGE BLACK/WHITE/RED/GREEN/ORANGE

Standards & References

  • ASTM B3, B174
  • NEC 400
  • MSHA
  • Federal and Military Specification JC-580B
  • RoHS-2 (European Directive 2011/65/EU )

Construction

  • Conductors: Class K stranded bare copper per ASTM B-174
  • Insulation: EPDM
  • Jacket: Black CPE (Other colors available upon request)

Resources

There are no downloadable resources for this product.