RHINOFLEXTM Type G-G cable is a heavy-duty cable for use where flexibility and maximum protection is required. For use with all portable, temporary, and permanent power applications such as mobile or stationary mining equipment, shuttle cars, mobile drills, pumps, roof bolters, conveyors, and any portable power where equipment grounding is required, It is ideal for use anytime extra-durable, flexible cable is required. Also suitable for continuous submersion in water. Ground check conductor provides fail-safe ground monitoring. Embossed print legend for easy cable identification. Cold Bend and Impact Tested to -50°C.
Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Inner Layer Thickness (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground Check Size | Inner Jacket Thickness (mils) (mm) | Outer Layer Thickness (mils) (mm) | Approx. OD (in) (cm) | Approx. Weight (lbs/1000') (kgs/km) | |
More Options |
8 AWG
8 AWG
|
3.0
3.0
|
168
168
|
0.153
0.39
|
60
1.52
|
0.287
0.73
|
10
10
|
55
1.40
|
145
3.68
|
1.026
2.61
|
661
984
|
More Options |
6 AWG
6 AWG
|
3.0
3.0
|
133
133
|
0.198
0.50
|
60
1.52
|
0.336
0.85
|
10
10
|
55
1.40
|
95
2.41
|
1.050
2.67
|
789
1174
|
More Options |
4 AWG
4 AWG
|
3.0
3.0
|
259
259
|
0.235
0.60
|
60
1.52
|
0.388
0.99
|
10
10
|
60
1.52
|
95
2.41
|
1.190
3.02
|
1014
1509
|
More Options |
2 AWG
2 AWG
|
3.0
3.0
|
308
308
|
0.302
0.77
|
60
1.52
|
0.452
1.15
|
8
8
|
65
1.65
|
90
2.29
|
1.325
3.37
|
1413
2103
|
More Options |
2/0 AWG
2/0 AWG
|
3.0
3.0
|
324
324
|
0.400
1.02
|
80
2.03
|
0.594
1.51
|
8
8
|
85
2.16
|
100
2.54
|
1.636
4.16
|
2401
3573
|
More Options |
4/0 AWG
4/0 AWG
|
3.0
3.0
|
532
532
|
0.550
1.40
|
80
2.03
|
0.751
1.91
|
8
8
|
80
2.03
|
135
3.43
|
2.040
5.18
|
3715
5529
|
More Options |
250 KCMIL
250 KCMIL
|
3.0
3.0
|
608
608
|
0.682
1.73
|
100
2.54
|
0.816
2.07
|
8
8
|
100
2.54
|
120
3.05
|
2.390
6.07
|
4386
6527
|
More Options |
350 KCMIL
350 KCMIL
|
3.0
3.0
|
855
855
|
0.809
2.05
|
100
2.54
|
0.926
2.35
|
8
8
|
100
2.54
|
125
3.18
|
2.680
6.81
|
5801
8633
|
Cond. Size | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | Rated Strength (lbs) (kg) | Min. Bend Radius (in) (cm) | Allowable Ampacity In Air 90C | |
More Options |
8 AWG
8 AWG
|
0.715
1.06
|
0.903
1.34
|
0.036
0.05
|
112
50.80
|
8.2
20.83
|
59
59
|
More Options |
6 AWG
6 AWG
|
0.450
0.67
|
0.568
0.85
|
0.034
0.05
|
179
81.19
|
8.4
21.34
|
79
79
|
More Options |
4 AWG
4 AWG
|
0.282
0.42
|
0.356
0.53
|
0.033
0.05
|
285
129.27
|
9.5
24.13
|
104
104
|
More Options |
2 AWG
2 AWG
|
0.179
0.27
|
0.226
0.34
|
0.031
0.05
|
453
205.48
|
10.6
26.92
|
138
138
|
More Options |
2/0 AWG
2/0 AWG
|
0.090
0.13
|
0.114
0.17
|
0.030
0.04
|
910
412.77
|
13.0
33.02
|
215
215
|
More Options |
4/0 AWG
4/0 AWG
|
0.057
0.08
|
0.073
0.11
|
0.029
0.04
|
1447
656.35
|
16.3
41.40
|
287
287
|
More Options |
250 KCMIL
250 KCMIL
|
0.048
0.07
|
0.062
0.09
|
0.026
0.04
|
1710
775.64
|
19.1
48.51
|
320
320
|
More Options |
350 KCMIL
350 KCMIL
|
0.035
0.05
|
0.046
0.07
|
0.025
0.04
|
2394
1085.90
|
21.4
54.36
|
394
394
|
* Ampacities based upon ICEA S-75-381 Table H-1.