ACSR-Aluminum Conductor, Steel Reinforced
Codeword | Size (AWG or kcmil) (mm2) | No. of Strands | Nom. OD (mils) (mm) | Nominal Total Weight (lbs/1000') (kgs/km) | |||||
101162 |
TURKEY
TURKEY
|
6 AWG
6 AWG
|
6
6
|
198
5.04
|
36
54
|
||||
101170 |
SWAN
SWAN
|
4 AWG
4 AWG
|
6
6
|
250
6.36
|
57
85
|
||||
101196 |
SPARROW
SPARROW
|
2 AWG
2 AWG
|
6
6
|
315
8.02
|
91
136
|
||||
101212 |
ROBIN
ROBIN
|
1 AWG
1 AWG
|
6
6
|
354
9.00
|
115
171
|
||||
101220 |
RAVEN
RAVEN
|
1/0 AWG
1/0 AWG
|
6
6
|
398
10.11
|
145
216
|
||||
101238 |
QUAIL
QUAIL
|
2/0 AWG
2/0 AWG
|
6
6
|
446
11.35
|
183
272
|
||||
101246 |
PIGEON
PIGEON
|
3/0 AWG
3/0 AWG
|
6
6
|
501
12.74
|
230
343
|
||||
101253 |
PENGUIN
PENGUIN
|
4/0 AWG
4/0 AWG
|
6
6
|
563
14.31
|
291
433
|
||||
618294 |
MAGPIE
MAGPIE
|
20.87 KCMIL
20.87 KCMIL
|
3
3
|
250
6.36
|
38
56
|
||||
101816 |
GROUSE
GROUSE
|
80 KCMIL
80 KCMIL
|
8
8
|
367
9.32
|
149
222
|
||||
101832 |
MINORCA
MINORCA
|
110.8 KCMIL
110.8 KCMIL
|
12
12
|
480
12.20
|
276
411
|
||||
101857 |
GUINEA
GUINEA
|
159 KCMIL
159 KCMIL
|
12
12
|
575
14.62
|
396
590
|
||||
101873 |
DORKING
DORKING
|
190.8 KCMIL
190.8 KCMIL
|
12
12
|
628
15.95
|
472
702
|
||||
101261 |
WAXWING
WAXWING
|
266.8 KCMIL
266.8 KCMIL
|
18
18
|
608
15.46
|
289
430
|
||||
621641 |
OSTRICH
OSTRICH
|
300 KCMIL
300 KCMIL
|
26
26
|
680
17.27
|
412
613
|
||||
101279 |
MERLIN
MERLIN
|
336.4 KCMIL
336.4 KCMIL
|
18
18
|
683
17.36
|
365
543
|
||||
101287 |
CHICKADEE
CHICKADEE
|
397.5 KCMIL
397.5 KCMIL
|
18
18
|
743
18.87
|
431
641
|
||||
101295 |
PELICAN
PELICAN
|
477 KCMIL
477 KCMIL
|
18
18
|
814
20.68
|
517
770
|
||||
101303 |
OSPREY
OSPREY
|
556.5 KCMIL
556.5 KCMIL
|
18
18
|
879
22.33
|
603
898
|
||||
101469 |
PEACOCK
PEACOCK
|
605 KCMIL
605 KCMIL
|
24
24
|
952
24.20
|
779
1159
|
||||
101311 |
KINGBIRD
KINGBIRD
|
636 KCMIL
636 KCMIL
|
18
18
|
940
23.88
|
690
1027
|
||||
101337 |
COOT
COOT
|
795 KCMIL
795 KCMIL
|
36
36
|
1040
26.42
|
804
1196
|
||||
101584 |
CANARY
CANARY
|
900 KCMIL
900 KCMIL
|
54
54
|
1161
29.51
|
1158
1723
|
||||
101592 |
RAIL
RAIL
|
954 KCMIL
954 KCMIL
|
45
45
|
1164
29.58
|
1074
1598
|
||||
101618 |
ORTOLAN
ORTOLAN
|
1033.5 KCMIL
1033.5 KCMIL
|
45
45
|
1212
30.78
|
1163
1730
|
||||
101634 |
BLUEJAY
BLUEJAY
|
1113 KCMIL
1113 KCMIL
|
45
45
|
1258
31.97
|
1254
1865
|
||||
101642 |
BUNTING
BUNTING
|
1192.5 KCMIL
1192.5 KCMIL
|
45
45
|
1302
33.08
|
1342
1998
|
||||
101659 |
BITTERN
BITTERN
|
1272 KCMIL
1272 KCMIL
|
45
45
|
1344
34.16
|
1432
2130
|
||||
101667 |
DIPPER
DIPPER
|
1351.5 KCMIL
1351.5 KCMIL
|
45
45
|
1386
35.21
|
1521
2264
|
||||
101675 |
BOBOLINK
BOBOLINK
|
1431 KCMIL
1431 KCMIL
|
45
45
|
1426
36.23
|
1611
2397
|
||||
101691 |
LAPWING
LAPWING
|
1590 KCMIL
1590 KCMIL
|
45
45
|
1503
38.20
|
1790
2664
|
||||
226043 |
CHUKAR
CHUKAR
|
1780 KCMIL
1780 KCMIL
|
84
84
|
1601
40.69
|
2072
3084
|
||||
621024 |
ROADRUNNER
ROADRUNNER
|
2057 KCMIL
2057 KCMIL
|
76
76
|
1700
43.18
|
2243
3337
|
||||
194241 |
BLUEBIRD
BLUEBIRD
|
2156 KCMIL
2156 KCMIL
|
84
84
|
1762
44.76
|
2508
3732
|
||||
226035 |
KIWI
KIWI
|
2167 KCMIL
2167 KCMIL
|
72
72
|
1735
44.07
|
2300
3423
|
||||
611809 |
THRASHER
THRASHER
|
2312 KCMIL
2312 KCMIL
|
76
76
|
1802
45.78
|
2523
3755
|
||||
225995 |
JOREE
JOREE
|
2515 KCMIL
2515 KCMIL
|
76
76
|
1879
47.74
|
2745
4085
|
||||
620780 |
|
2839.8 KCMIL
2839.8 KCMIL
|
72
72
|
1986
50.44
|
3014
4485
|
Southwire's ACSR bare conductor meets or exceeds the following ASTM specifications: